The correct assessment of standard potentials of reference electrodes in non-aqueous solution

Autores
Mozhzhukhina, Nataliia; Calvo, Ernesto Julio
Año de publicación
2017
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
The challenges facing metal-air batteries have prompted fundamental studies of non-aqueous electrochemistry. However it appears that contributors in the field are not aware that the potentials of Li/Li+, Na/Na+, K/K+, and Mg/Mg2+ electrodes depend on the nature of solvent due to the cation solvation. Therefore, it is imperative to define a clear potential scale that can be correlated in different solvents. Here we report on the strong effect of the solvent on the Li/Li+ redox potential and discuss the use of the ferrocene/ferrocenium couple as internal or external standard for the measurements in non-aqueous solvents in lithium-ion and lithium-02 battery systems.
Fil: Mozhzhukhina, Nataliia. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química, Física de los Materiales, Medioambiente y Energía. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química, Física de los Materiales, Medioambiente y Energía; Argentina
Fil: Calvo, Ernesto Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química, Física de los Materiales, Medioambiente y Energía. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química, Física de los Materiales, Medioambiente y Energía; Argentina
Materia
lithium
aprotic
potential
reference electrode
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/65540

id CONICETDig_b118ebd2cf24a476abf6da1df80dab94
oai_identifier_str oai:ri.conicet.gov.ar:11336/65540
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling The correct assessment of standard potentials of reference electrodes in non-aqueous solutionMozhzhukhina, NataliiaCalvo, Ernesto Juliolithiumaproticpotentialreference electrodehttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1The challenges facing metal-air batteries have prompted fundamental studies of non-aqueous electrochemistry. However it appears that contributors in the field are not aware that the potentials of Li/Li+, Na/Na+, K/K+, and Mg/Mg2+ electrodes depend on the nature of solvent due to the cation solvation. Therefore, it is imperative to define a clear potential scale that can be correlated in different solvents. Here we report on the strong effect of the solvent on the Li/Li+ redox potential and discuss the use of the ferrocene/ferrocenium couple as internal or external standard for the measurements in non-aqueous solvents in lithium-ion and lithium-02 battery systems.Fil: Mozhzhukhina, Nataliia. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química, Física de los Materiales, Medioambiente y Energía. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química, Física de los Materiales, Medioambiente y Energía; ArgentinaFil: Calvo, Ernesto Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química, Física de los Materiales, Medioambiente y Energía. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química, Física de los Materiales, Medioambiente y Energía; ArgentinaElectrochemical Society2017-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/65540Mozhzhukhina, Nataliia; Calvo, Ernesto Julio; The correct assessment of standard potentials of reference electrodes in non-aqueous solution; Electrochemical Society; Journal of the Electrochemical Society; 164; 12; 11-2017; A2295-A22970013-4651CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1149/2.0341712jesinfo:eu-repo/semantics/altIdentifier/url/http://jes.ecsdl.org/content/164/12/A2295info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T15:13:18Zoai:ri.conicet.gov.ar:11336/65540instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 15:13:18.922CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv The correct assessment of standard potentials of reference electrodes in non-aqueous solution
title The correct assessment of standard potentials of reference electrodes in non-aqueous solution
spellingShingle The correct assessment of standard potentials of reference electrodes in non-aqueous solution
Mozhzhukhina, Nataliia
lithium
aprotic
potential
reference electrode
title_short The correct assessment of standard potentials of reference electrodes in non-aqueous solution
title_full The correct assessment of standard potentials of reference electrodes in non-aqueous solution
title_fullStr The correct assessment of standard potentials of reference electrodes in non-aqueous solution
title_full_unstemmed The correct assessment of standard potentials of reference electrodes in non-aqueous solution
title_sort The correct assessment of standard potentials of reference electrodes in non-aqueous solution
dc.creator.none.fl_str_mv Mozhzhukhina, Nataliia
Calvo, Ernesto Julio
author Mozhzhukhina, Nataliia
author_facet Mozhzhukhina, Nataliia
Calvo, Ernesto Julio
author_role author
author2 Calvo, Ernesto Julio
author2_role author
dc.subject.none.fl_str_mv lithium
aprotic
potential
reference electrode
topic lithium
aprotic
potential
reference electrode
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv The challenges facing metal-air batteries have prompted fundamental studies of non-aqueous electrochemistry. However it appears that contributors in the field are not aware that the potentials of Li/Li+, Na/Na+, K/K+, and Mg/Mg2+ electrodes depend on the nature of solvent due to the cation solvation. Therefore, it is imperative to define a clear potential scale that can be correlated in different solvents. Here we report on the strong effect of the solvent on the Li/Li+ redox potential and discuss the use of the ferrocene/ferrocenium couple as internal or external standard for the measurements in non-aqueous solvents in lithium-ion and lithium-02 battery systems.
Fil: Mozhzhukhina, Nataliia. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química, Física de los Materiales, Medioambiente y Energía. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química, Física de los Materiales, Medioambiente y Energía; Argentina
Fil: Calvo, Ernesto Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Química, Física de los Materiales, Medioambiente y Energía. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Química, Física de los Materiales, Medioambiente y Energía; Argentina
description The challenges facing metal-air batteries have prompted fundamental studies of non-aqueous electrochemistry. However it appears that contributors in the field are not aware that the potentials of Li/Li+, Na/Na+, K/K+, and Mg/Mg2+ electrodes depend on the nature of solvent due to the cation solvation. Therefore, it is imperative to define a clear potential scale that can be correlated in different solvents. Here we report on the strong effect of the solvent on the Li/Li+ redox potential and discuss the use of the ferrocene/ferrocenium couple as internal or external standard for the measurements in non-aqueous solvents in lithium-ion and lithium-02 battery systems.
publishDate 2017
dc.date.none.fl_str_mv 2017-11
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/65540
Mozhzhukhina, Nataliia; Calvo, Ernesto Julio; The correct assessment of standard potentials of reference electrodes in non-aqueous solution; Electrochemical Society; Journal of the Electrochemical Society; 164; 12; 11-2017; A2295-A2297
0013-4651
CONICET Digital
CONICET
url http://hdl.handle.net/11336/65540
identifier_str_mv Mozhzhukhina, Nataliia; Calvo, Ernesto Julio; The correct assessment of standard potentials of reference electrodes in non-aqueous solution; Electrochemical Society; Journal of the Electrochemical Society; 164; 12; 11-2017; A2295-A2297
0013-4651
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1149/2.0341712jes
info:eu-repo/semantics/altIdentifier/url/http://jes.ecsdl.org/content/164/12/A2295
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Electrochemical Society
publisher.none.fl_str_mv Electrochemical Society
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1846083281040179200
score 13.22299