Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations
- Autores
- Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta
- Año de publicación
- 2014
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes.
Fil: Lebed, Pablo Jorge. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Keunchkarian, Sonia. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Osorio Grisales, Jaiver. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Castells, Cecilia Beatriz Marta. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina - Materia
-
Chiral Gas-Liquid Chromatography
Association Constants
Capillary Columns
Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/11177
Ver los metadatos del registro completo
id |
CONICETDig_aa47f55c9d3456cc453159cfa85d647a |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/11177 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerationsLebed, Pablo JorgeKeunchkarian, SoniaOsorio Grisales, JaiverCastells, Cecilia Beatriz MartaChiral Gas-Liquid ChromatographyAssociation ConstantsCapillary ColumnsOctakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrinhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes.Fil: Lebed, Pablo Jorge. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Keunchkarian, Sonia. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Osorio Grisales, Jaiver. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Castells, Cecilia Beatriz Marta. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaElsevier Science2014-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/mswordapplication/pdfhttp://hdl.handle.net/11336/11177Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta; Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations; Elsevier Science; Journal Of Chromatography - A; 1324; 1-2014; 198-2060021-9673enginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2013.11.007info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0021967313017627info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:50:00Zoai:ri.conicet.gov.ar:11336/11177instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:50:00.499CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
title |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
spellingShingle |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations Lebed, Pablo Jorge Chiral Gas-Liquid Chromatography Association Constants Capillary Columns Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin |
title_short |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
title_full |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
title_fullStr |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
title_full_unstemmed |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
title_sort |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
dc.creator.none.fl_str_mv |
Lebed, Pablo Jorge Keunchkarian, Sonia Osorio Grisales, Jaiver Castells, Cecilia Beatriz Marta |
author |
Lebed, Pablo Jorge |
author_facet |
Lebed, Pablo Jorge Keunchkarian, Sonia Osorio Grisales, Jaiver Castells, Cecilia Beatriz Marta |
author_role |
author |
author2 |
Keunchkarian, Sonia Osorio Grisales, Jaiver Castells, Cecilia Beatriz Marta |
author2_role |
author author author |
dc.subject.none.fl_str_mv |
Chiral Gas-Liquid Chromatography Association Constants Capillary Columns Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin |
topic |
Chiral Gas-Liquid Chromatography Association Constants Capillary Columns Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes. Fil: Lebed, Pablo Jorge. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Keunchkarian, Sonia. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Osorio Grisales, Jaiver. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Castells, Cecilia Beatriz Marta. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina |
description |
The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/11177 Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta; Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations; Elsevier Science; Journal Of Chromatography - A; 1324; 1-2014; 198-206 0021-9673 |
url |
http://hdl.handle.net/11336/11177 |
identifier_str_mv |
Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta; Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations; Elsevier Science; Journal Of Chromatography - A; 1324; 1-2014; 198-206 0021-9673 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2013.11.007 info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0021967313017627 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/msword application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613543737950208 |
score |
13.070432 |