Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations
- Autores
- Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta
- Año de publicación
- 2014
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes.
Fil: Lebed, Pablo Jorge. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Keunchkarian, Sonia. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Osorio Grisales, Jaiver. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Castells, Cecilia Beatriz Marta. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina - Materia
-
Chiral Gas-Liquid Chromatography
Association Constants
Capillary Columns
Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/11177
Ver los metadatos del registro completo
| id |
CONICETDig_aa47f55c9d3456cc453159cfa85d647a |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/11177 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerationsLebed, Pablo JorgeKeunchkarian, SoniaOsorio Grisales, JaiverCastells, Cecilia Beatriz MartaChiral Gas-Liquid ChromatographyAssociation ConstantsCapillary ColumnsOctakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrinhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes.Fil: Lebed, Pablo Jorge. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Keunchkarian, Sonia. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Osorio Grisales, Jaiver. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Castells, Cecilia Beatriz Marta. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaElsevier Science2014-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/mswordapplication/pdfhttp://hdl.handle.net/11336/11177Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta; Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations; Elsevier Science; Journal Of Chromatography - A; 1324; 1-2014; 198-2060021-9673enginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2013.11.007info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0021967313017627info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-11-12T09:41:21Zoai:ri.conicet.gov.ar:11336/11177instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-11-12 09:41:21.869CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
| title |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
| spellingShingle |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations Lebed, Pablo Jorge Chiral Gas-Liquid Chromatography Association Constants Capillary Columns Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin |
| title_short |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
| title_full |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
| title_fullStr |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
| title_full_unstemmed |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
| title_sort |
Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations |
| dc.creator.none.fl_str_mv |
Lebed, Pablo Jorge Keunchkarian, Sonia Osorio Grisales, Jaiver Castells, Cecilia Beatriz Marta |
| author |
Lebed, Pablo Jorge |
| author_facet |
Lebed, Pablo Jorge Keunchkarian, Sonia Osorio Grisales, Jaiver Castells, Cecilia Beatriz Marta |
| author_role |
author |
| author2 |
Keunchkarian, Sonia Osorio Grisales, Jaiver Castells, Cecilia Beatriz Marta |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Chiral Gas-Liquid Chromatography Association Constants Capillary Columns Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin |
| topic |
Chiral Gas-Liquid Chromatography Association Constants Capillary Columns Octakis(3-O-Butanoyl-2,6-Di-O-Pentyl)-Γ-Cyclodextrin |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
| dc.description.none.fl_txt_mv |
The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes. Fil: Lebed, Pablo Jorge. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Keunchkarian, Sonia. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Osorio Grisales, Jaiver. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Castells, Cecilia Beatriz Marta. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación y Desarrollo de Métodos Analíticos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina |
| description |
The association constants of several volatile enantiomers with octakis(3-O-butanoyl-2,6-di-O-pentyl)-γ-cyclodextrin at temperatures between 50 and 100 °C were measured by gas–liquid chromatography using capillary columns coated with different amounts of chiral selector dissolved in polysiloxane OV-1701 and prepared with a precisely determined phase ratio. Simple expressions were deduced to estimate the apparent distribution constants from accurate hold-up and retention times along with that known phase ratio at each temperature. The enantiomer-chiral selector association constants were then calculated from the linear regression of the apparent constants as a function of the chiral selector concentration. One aim of this study consisted in discussing all the experimental uncertainties inherent in the determination of enantiomer/selector association constants with chiral analytes, and how these fundamental measurements can be performed precisely without resorting to the use of reference solutes. |
| publishDate |
2014 |
| dc.date.none.fl_str_mv |
2014-01 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/11177 Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta; Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations; Elsevier Science; Journal Of Chromatography - A; 1324; 1-2014; 198-206 0021-9673 |
| url |
http://hdl.handle.net/11336/11177 |
| identifier_str_mv |
Lebed, Pablo Jorge; Keunchkarian, Sonia; Osorio Grisales, Jaiver; Castells, Cecilia Beatriz Marta; Measurements of association constants between enantiomers and chiral selectors by capillary gas chromatography. Theoretical and practical considerations; Elsevier Science; Journal Of Chromatography - A; 1324; 1-2014; 198-206 0021-9673 |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2013.11.007 info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0021967313017627 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/msword application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier Science |
| publisher.none.fl_str_mv |
Elsevier Science |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1848597569771405312 |
| score |
13.3211565 |