Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells

Autores
Giana, Fabián Eduardo; Bonetto, Fabian Jose; Bellotti, Mariela
Año de publicación
2018
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
In this work we present an assay to discriminate between normal and cancerous cells. The method is based on the measurement of electrical impedance spectra of in vitro cell cultures. We developed a protocol consisting on four consecutive measurement phases, each of them designed to obtain different information about the cell cultures. Through the analysis of the measured data, 26 characteristic features were obtained for both cell types. From the complete set of features, we selected the most relevant in terms of their discriminant capacity by means of conventional statistical tests. A linear discriminant analysis was then carried out on the selected features, allowing the classification of the samples in normal or cancerous with 4.5% of false positives and no false negatives.
Fil: Giana, Fabián Eduardo. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; Argentina
Fil: Bonetto, Fabian Jose. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; Argentina
Fil: Bellotti, Mariela. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina
Materia
DISCRIMINATE
CELL
IMPEDANCE
STATISTICAL TESTS
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/125513

id CONICETDig_a9c31c05b73357de99b7b930f6933f15
oai_identifier_str oai:ri.conicet.gov.ar:11336/125513
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cellsGiana, Fabián EduardoBonetto, Fabian JoseBellotti, MarielaDISCRIMINATECELLIMPEDANCESTATISTICAL TESTShttps://purl.org/becyt/ford/1.6https://purl.org/becyt/ford/1In this work we present an assay to discriminate between normal and cancerous cells. The method is based on the measurement of electrical impedance spectra of in vitro cell cultures. We developed a protocol consisting on four consecutive measurement phases, each of them designed to obtain different information about the cell cultures. Through the analysis of the measured data, 26 characteristic features were obtained for both cell types. From the complete set of features, we selected the most relevant in terms of their discriminant capacity by means of conventional statistical tests. A linear discriminant analysis was then carried out on the selected features, allowing the classification of the samples in normal or cancerous with 4.5% of false positives and no false negatives.Fil: Giana, Fabián Eduardo. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; ArgentinaFil: Bonetto, Fabian Jose. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; ArgentinaFil: Bellotti, Mariela. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; ArgentinaAmerican Physical Society2018-03-19info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/125513Giana, Fabián Eduardo; Bonetto, Fabian Jose; Bellotti, Mariela; Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells; American Physical Society; Physical Review E: Statistical, Nonlinear and Soft Matter Physics; 97; 3; 19-3-2018; 1-101539-3755CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://link.aps.org/doi/10.1103/PhysRevE.97.032410info:eu-repo/semantics/altIdentifier/doi/10.1103/PhysRevE.97.032410info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T10:09:20Zoai:ri.conicet.gov.ar:11336/125513instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 10:09:20.93CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
title Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
spellingShingle Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
Giana, Fabián Eduardo
DISCRIMINATE
CELL
IMPEDANCE
STATISTICAL TESTS
title_short Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
title_full Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
title_fullStr Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
title_full_unstemmed Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
title_sort Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
dc.creator.none.fl_str_mv Giana, Fabián Eduardo
Bonetto, Fabian Jose
Bellotti, Mariela
author Giana, Fabián Eduardo
author_facet Giana, Fabián Eduardo
Bonetto, Fabian Jose
Bellotti, Mariela
author_role author
author2 Bonetto, Fabian Jose
Bellotti, Mariela
author2_role author
author
dc.subject.none.fl_str_mv DISCRIMINATE
CELL
IMPEDANCE
STATISTICAL TESTS
topic DISCRIMINATE
CELL
IMPEDANCE
STATISTICAL TESTS
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.6
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv In this work we present an assay to discriminate between normal and cancerous cells. The method is based on the measurement of electrical impedance spectra of in vitro cell cultures. We developed a protocol consisting on four consecutive measurement phases, each of them designed to obtain different information about the cell cultures. Through the analysis of the measured data, 26 characteristic features were obtained for both cell types. From the complete set of features, we selected the most relevant in terms of their discriminant capacity by means of conventional statistical tests. A linear discriminant analysis was then carried out on the selected features, allowing the classification of the samples in normal or cancerous with 4.5% of false positives and no false negatives.
Fil: Giana, Fabián Eduardo. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; Argentina
Fil: Bonetto, Fabian Jose. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Patagonia Norte; Argentina
Fil: Bellotti, Mariela. Comisión Nacional de Energía Atómica. Gerencia de Área de Energía Nuclear. Gerencia de Ingeniería Nuclear (CAB). Laboratorio Cavitación y Biotecnología; Argentina. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina
description In this work we present an assay to discriminate between normal and cancerous cells. The method is based on the measurement of electrical impedance spectra of in vitro cell cultures. We developed a protocol consisting on four consecutive measurement phases, each of them designed to obtain different information about the cell cultures. Through the analysis of the measured data, 26 characteristic features were obtained for both cell types. From the complete set of features, we selected the most relevant in terms of their discriminant capacity by means of conventional statistical tests. A linear discriminant analysis was then carried out on the selected features, allowing the classification of the samples in normal or cancerous with 4.5% of false positives and no false negatives.
publishDate 2018
dc.date.none.fl_str_mv 2018-03-19
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/125513
Giana, Fabián Eduardo; Bonetto, Fabian Jose; Bellotti, Mariela; Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells; American Physical Society; Physical Review E: Statistical, Nonlinear and Soft Matter Physics; 97; 3; 19-3-2018; 1-10
1539-3755
CONICET Digital
CONICET
url http://hdl.handle.net/11336/125513
identifier_str_mv Giana, Fabián Eduardo; Bonetto, Fabian Jose; Bellotti, Mariela; Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells; American Physical Society; Physical Review E: Statistical, Nonlinear and Soft Matter Physics; 97; 3; 19-3-2018; 1-10
1539-3755
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://link.aps.org/doi/10.1103/PhysRevE.97.032410
info:eu-repo/semantics/altIdentifier/doi/10.1103/PhysRevE.97.032410
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv American Physical Society
publisher.none.fl_str_mv American Physical Society
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842270077066412032
score 13.13397