Skin-electrode impedance measurement during ECG acquisition: Method's validation

Autores
Casal, Leonardo; la Mura, Guillermo Mario
Año de publicación
2016
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.
Fil: Casal, Leonardo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; Argentina
Fil: la Mura, Guillermo Mario. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; Argentina
Materia
electrode
impedance
ecg
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/90825

id CONICETDig_9c1075f023c106a753307f976906ac70
oai_identifier_str oai:ri.conicet.gov.ar:11336/90825
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Skin-electrode impedance measurement during ECG acquisition: Method's validationCasal, Leonardola Mura, Guillermo Marioelectrodeimpedanceecghttps://purl.org/becyt/ford/2.6https://purl.org/becyt/ford/2Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.Fil: Casal, Leonardo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; ArgentinaFil: la Mura, Guillermo Mario. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; ArgentinaIOP Publishing2016-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/90825Casal, Leonardo; la Mura, Guillermo Mario; Skin-electrode impedance measurement during ECG acquisition: Method's validation; IOP Publishing; Journal of Physics: Conference Series; 705; 1; 4-2016; 1-71742-6596CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1742-6596/705/1/012006info:eu-repo/semantics/altIdentifier/doi/10.1088/1742-6596/705/1/012006info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T14:27:08Zoai:ri.conicet.gov.ar:11336/90825instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 14:27:08.453CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Skin-electrode impedance measurement during ECG acquisition: Method's validation
title Skin-electrode impedance measurement during ECG acquisition: Method's validation
spellingShingle Skin-electrode impedance measurement during ECG acquisition: Method's validation
Casal, Leonardo
electrode
impedance
ecg
title_short Skin-electrode impedance measurement during ECG acquisition: Method's validation
title_full Skin-electrode impedance measurement during ECG acquisition: Method's validation
title_fullStr Skin-electrode impedance measurement during ECG acquisition: Method's validation
title_full_unstemmed Skin-electrode impedance measurement during ECG acquisition: Method's validation
title_sort Skin-electrode impedance measurement during ECG acquisition: Method's validation
dc.creator.none.fl_str_mv Casal, Leonardo
la Mura, Guillermo Mario
author Casal, Leonardo
author_facet Casal, Leonardo
la Mura, Guillermo Mario
author_role author
author2 la Mura, Guillermo Mario
author2_role author
dc.subject.none.fl_str_mv electrode
impedance
ecg
topic electrode
impedance
ecg
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.6
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.
Fil: Casal, Leonardo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; Argentina
Fil: la Mura, Guillermo Mario. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; Argentina
description Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.
publishDate 2016
dc.date.none.fl_str_mv 2016-04
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/90825
Casal, Leonardo; la Mura, Guillermo Mario; Skin-electrode impedance measurement during ECG acquisition: Method's validation; IOP Publishing; Journal of Physics: Conference Series; 705; 1; 4-2016; 1-7
1742-6596
CONICET Digital
CONICET
url http://hdl.handle.net/11336/90825
identifier_str_mv Casal, Leonardo; la Mura, Guillermo Mario; Skin-electrode impedance measurement during ECG acquisition: Method's validation; IOP Publishing; Journal of Physics: Conference Series; 705; 1; 4-2016; 1-7
1742-6596
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1742-6596/705/1/012006
info:eu-repo/semantics/altIdentifier/doi/10.1088/1742-6596/705/1/012006
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv IOP Publishing
publisher.none.fl_str_mv IOP Publishing
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1846082724686725120