Skin-electrode impedance measurement during ECG acquisition: Method's validation
- Autores
- Casal, Leonardo; la Mura, Guillermo Mario
- Año de publicación
- 2016
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.
Fil: Casal, Leonardo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; Argentina
Fil: la Mura, Guillermo Mario. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; Argentina - Materia
-
electrode
impedance
ecg - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/90825
Ver los metadatos del registro completo
id |
CONICETDig_9c1075f023c106a753307f976906ac70 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/90825 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Skin-electrode impedance measurement during ECG acquisition: Method's validationCasal, Leonardola Mura, Guillermo Marioelectrodeimpedanceecghttps://purl.org/becyt/ford/2.6https://purl.org/becyt/ford/2Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration.Fil: Casal, Leonardo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; ArgentinaFil: la Mura, Guillermo Mario. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; ArgentinaIOP Publishing2016-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/90825Casal, Leonardo; la Mura, Guillermo Mario; Skin-electrode impedance measurement during ECG acquisition: Method's validation; IOP Publishing; Journal of Physics: Conference Series; 705; 1; 4-2016; 1-71742-6596CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1742-6596/705/1/012006info:eu-repo/semantics/altIdentifier/doi/10.1088/1742-6596/705/1/012006info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T14:27:08Zoai:ri.conicet.gov.ar:11336/90825instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 14:27:08.453CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Skin-electrode impedance measurement during ECG acquisition: Method's validation |
title |
Skin-electrode impedance measurement during ECG acquisition: Method's validation |
spellingShingle |
Skin-electrode impedance measurement during ECG acquisition: Method's validation Casal, Leonardo electrode impedance ecg |
title_short |
Skin-electrode impedance measurement during ECG acquisition: Method's validation |
title_full |
Skin-electrode impedance measurement during ECG acquisition: Method's validation |
title_fullStr |
Skin-electrode impedance measurement during ECG acquisition: Method's validation |
title_full_unstemmed |
Skin-electrode impedance measurement during ECG acquisition: Method's validation |
title_sort |
Skin-electrode impedance measurement during ECG acquisition: Method's validation |
dc.creator.none.fl_str_mv |
Casal, Leonardo la Mura, Guillermo Mario |
author |
Casal, Leonardo |
author_facet |
Casal, Leonardo la Mura, Guillermo Mario |
author_role |
author |
author2 |
la Mura, Guillermo Mario |
author2_role |
author |
dc.subject.none.fl_str_mv |
electrode impedance ecg |
topic |
electrode impedance ecg |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.6 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration. Fil: Casal, Leonardo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; Argentina Fil: la Mura, Guillermo Mario. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología; Argentina |
description |
Skm-electrode impedance measurement can provide valuable information prior. dunng and post electrocardiographic (ECG) or electroencephalographs (EEG) acquisitions. In this work we validate a method for skm-electrode impedance measurement using test circuits with known resistance and capacitor values, at different frequencies for injected excitation current. Finally the method is successfully used for impedance measurement during ECG acquisition on a subject usmg 125 Hz and 6 nA square wave excitation signal at instrumentation amplifier mput. The method can be used for many electrodes configuration. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-04 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/90825 Casal, Leonardo; la Mura, Guillermo Mario; Skin-electrode impedance measurement during ECG acquisition: Method's validation; IOP Publishing; Journal of Physics: Conference Series; 705; 1; 4-2016; 1-7 1742-6596 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/90825 |
identifier_str_mv |
Casal, Leonardo; la Mura, Guillermo Mario; Skin-electrode impedance measurement during ECG acquisition: Method's validation; IOP Publishing; Journal of Physics: Conference Series; 705; 1; 4-2016; 1-7 1742-6596 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1742-6596/705/1/012006 info:eu-repo/semantics/altIdentifier/doi/10.1088/1742-6596/705/1/012006 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
IOP Publishing |
publisher.none.fl_str_mv |
IOP Publishing |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1846082724686725120 |
score |
13.221938 |