Determination of flow patterns in a rotating disk electrode configuration by MRI

Autores
Carpinella, Mariela; Velasco, Manuel Isaac; Silletta, Emilia Victoria; Ovejero, Juan Manuel; Dassie, Sergio Alberto; Acosta, Rodolfo Héctor
Año de publicación
2015
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Velocity maps in an electrochemical cell model with a rotating disk electrode configuration were acquired by magnetic resonance imaging. This is one of the devices most widely used to characterize electrochemical reactions, where the relevant information needed is the velocity of the fluid ingoing the region of the electrode. Velocity maps of the whole cell were acquired with MRI for different rotating speeds and cell configuration. Results are in good agreement with previous data obtained by computational fluid dynamics (CFDs).
Fil: Carpinella, Mariela. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
Fil: Velasco, Manuel Isaac. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
Fil: Silletta, Emilia Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
Fil: Ovejero, Juan Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
Fil: Dassie, Sergio Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
Fil: Acosta, Rodolfo Héctor. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
Materia
MRI
ROTATING DISK ELECTRODE
TAYLOR COUETTE CELL
VELOCIMETRY
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/47149

id CONICETDig_9b3af344c7894b9902257de3a337c9c7
oai_identifier_str oai:ri.conicet.gov.ar:11336/47149
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Determination of flow patterns in a rotating disk electrode configuration by MRICarpinella, MarielaVelasco, Manuel IsaacSilletta, Emilia VictoriaOvejero, Juan ManuelDassie, Sergio AlbertoAcosta, Rodolfo HéctorMRIROTATING DISK ELECTRODETAYLOR COUETTE CELLVELOCIMETRYhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1Velocity maps in an electrochemical cell model with a rotating disk electrode configuration were acquired by magnetic resonance imaging. This is one of the devices most widely used to characterize electrochemical reactions, where the relevant information needed is the velocity of the fluid ingoing the region of the electrode. Velocity maps of the whole cell were acquired with MRI for different rotating speeds and cell configuration. Results are in good agreement with previous data obtained by computational fluid dynamics (CFDs).Fil: Carpinella, Mariela. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; ArgentinaFil: Velasco, Manuel Isaac. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; ArgentinaFil: Silletta, Emilia Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; ArgentinaFil: Ovejero, Juan Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Dassie, Sergio Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Acosta, Rodolfo Héctor. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; ArgentinaElsevier Science Sa2015-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/47149Carpinella, Mariela; Velasco, Manuel Isaac; Silletta, Emilia Victoria; Ovejero, Juan Manuel; Dassie, Sergio Alberto; et al.; Determination of flow patterns in a rotating disk electrode configuration by MRI; Elsevier Science Sa; Journal of Electroanalytical Chemistry; 750; 1-5-2015; 100-1061572-6657CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S1572665715002453info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jelechem.2015.05.018info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:06:40Zoai:ri.conicet.gov.ar:11336/47149instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:06:41.047CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Determination of flow patterns in a rotating disk electrode configuration by MRI
title Determination of flow patterns in a rotating disk electrode configuration by MRI
spellingShingle Determination of flow patterns in a rotating disk electrode configuration by MRI
Carpinella, Mariela
MRI
ROTATING DISK ELECTRODE
TAYLOR COUETTE CELL
VELOCIMETRY
title_short Determination of flow patterns in a rotating disk electrode configuration by MRI
title_full Determination of flow patterns in a rotating disk electrode configuration by MRI
title_fullStr Determination of flow patterns in a rotating disk electrode configuration by MRI
title_full_unstemmed Determination of flow patterns in a rotating disk electrode configuration by MRI
title_sort Determination of flow patterns in a rotating disk electrode configuration by MRI
dc.creator.none.fl_str_mv Carpinella, Mariela
Velasco, Manuel Isaac
Silletta, Emilia Victoria
Ovejero, Juan Manuel
Dassie, Sergio Alberto
Acosta, Rodolfo Héctor
author Carpinella, Mariela
author_facet Carpinella, Mariela
Velasco, Manuel Isaac
Silletta, Emilia Victoria
Ovejero, Juan Manuel
Dassie, Sergio Alberto
Acosta, Rodolfo Héctor
author_role author
author2 Velasco, Manuel Isaac
Silletta, Emilia Victoria
Ovejero, Juan Manuel
Dassie, Sergio Alberto
Acosta, Rodolfo Héctor
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv MRI
ROTATING DISK ELECTRODE
TAYLOR COUETTE CELL
VELOCIMETRY
topic MRI
ROTATING DISK ELECTRODE
TAYLOR COUETTE CELL
VELOCIMETRY
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv Velocity maps in an electrochemical cell model with a rotating disk electrode configuration were acquired by magnetic resonance imaging. This is one of the devices most widely used to characterize electrochemical reactions, where the relevant information needed is the velocity of the fluid ingoing the region of the electrode. Velocity maps of the whole cell were acquired with MRI for different rotating speeds and cell configuration. Results are in good agreement with previous data obtained by computational fluid dynamics (CFDs).
Fil: Carpinella, Mariela. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
Fil: Velasco, Manuel Isaac. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
Fil: Silletta, Emilia Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
Fil: Ovejero, Juan Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
Fil: Dassie, Sergio Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
Fil: Acosta, Rodolfo Héctor. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
description Velocity maps in an electrochemical cell model with a rotating disk electrode configuration were acquired by magnetic resonance imaging. This is one of the devices most widely used to characterize electrochemical reactions, where the relevant information needed is the velocity of the fluid ingoing the region of the electrode. Velocity maps of the whole cell were acquired with MRI for different rotating speeds and cell configuration. Results are in good agreement with previous data obtained by computational fluid dynamics (CFDs).
publishDate 2015
dc.date.none.fl_str_mv 2015-05-01
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/47149
Carpinella, Mariela; Velasco, Manuel Isaac; Silletta, Emilia Victoria; Ovejero, Juan Manuel; Dassie, Sergio Alberto; et al.; Determination of flow patterns in a rotating disk electrode configuration by MRI; Elsevier Science Sa; Journal of Electroanalytical Chemistry; 750; 1-5-2015; 100-106
1572-6657
CONICET Digital
CONICET
url http://hdl.handle.net/11336/47149
identifier_str_mv Carpinella, Mariela; Velasco, Manuel Isaac; Silletta, Emilia Victoria; Ovejero, Juan Manuel; Dassie, Sergio Alberto; et al.; Determination of flow patterns in a rotating disk electrode configuration by MRI; Elsevier Science Sa; Journal of Electroanalytical Chemistry; 750; 1-5-2015; 100-106
1572-6657
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S1572665715002453
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jelechem.2015.05.018
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier Science Sa
publisher.none.fl_str_mv Elsevier Science Sa
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844613918342774784
score 13.070432