v-MOKE magnetometry: a solution for devices with fixed electromagnet
- Autores
- Bonetto, Fernando Jose; Tacca, Marcos Sebastian; Aguzin, Ana; Butera, Alejandro Ricardo; Ferron, Julio; Bonin, Claudio Julio
- Año de publicación
- 2020
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- We introduce a novel method aimed to obtain the scale factor between in-plane magnetization components, indispensable for vectorial-magneto-optic Kerr effect (v-MOKE) experiments, convenient for experimental setups where it is difficult or unfeasible to rotate the electromagnet. Unlike the original method, in our proposal the electromagnet (and all other optical components) are fixed, extending in this way the possibility to implement v-MOKE magnetometry. Two films, FePt 9 and 100 nm thickness, were used as sample probes, presenting in-plane magnetic uniaxial anisotropy and in-plane magnetic isotropy, respectively. All experiments were carried out at room temperature and employing an home-made MOKE system. We also introduce a closed mathematical expression for the scale factor linking both magnetization components in terms of experimental and sample dependent parameters.
Fil: Bonetto, Fernando Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina
Fil: Tacca, Marcos Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina
Fil: Aguzin, Ana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Butera, Alejandro Ricardo. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro.; Argentina
Fil: Ferron, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina
Fil: Bonin, Claudio Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina - Materia
-
FEPT
MAGNETIC ANISOTROPIC FILM
NANOMAGNETISM
SCALING OF IN-PLANE MAGNETIC COMPONENTS
SURFACE MAGNETISM
VECTORIAL-MOKE - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/140140
Ver los metadatos del registro completo
id |
CONICETDig_99aff075fa2bf27e56c18bb2199675d3 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/140140 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
v-MOKE magnetometry: a solution for devices with fixed electromagnetBonetto, Fernando JoseTacca, Marcos SebastianAguzin, AnaButera, Alejandro RicardoFerron, JulioBonin, Claudio JulioFEPTMAGNETIC ANISOTROPIC FILMNANOMAGNETISMSCALING OF IN-PLANE MAGNETIC COMPONENTSSURFACE MAGNETISMVECTORIAL-MOKEhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1We introduce a novel method aimed to obtain the scale factor between in-plane magnetization components, indispensable for vectorial-magneto-optic Kerr effect (v-MOKE) experiments, convenient for experimental setups where it is difficult or unfeasible to rotate the electromagnet. Unlike the original method, in our proposal the electromagnet (and all other optical components) are fixed, extending in this way the possibility to implement v-MOKE magnetometry. Two films, FePt 9 and 100 nm thickness, were used as sample probes, presenting in-plane magnetic uniaxial anisotropy and in-plane magnetic isotropy, respectively. All experiments were carried out at room temperature and employing an home-made MOKE system. We also introduce a closed mathematical expression for the scale factor linking both magnetization components in terms of experimental and sample dependent parameters.Fil: Bonetto, Fernando Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; ArgentinaFil: Tacca, Marcos Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; ArgentinaFil: Aguzin, Ana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaFil: Butera, Alejandro Ricardo. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro.; ArgentinaFil: Ferron, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; ArgentinaFil: Bonin, Claudio Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; ArgentinaIOP Publishing2020-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/140140Bonetto, Fernando Jose; Tacca, Marcos Sebastian; Aguzin, Ana; Butera, Alejandro Ricardo; Ferron, Julio; et al.; v-MOKE magnetometry: a solution for devices with fixed electromagnet; IOP Publishing; Measurement Science & Technology (print); 31; 11; 5-2020; 1-60957-0233CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1361-6501/ab9411info:eu-repo/semantics/altIdentifier/doi/10.1088/1361-6501/ab9411info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:57:58Zoai:ri.conicet.gov.ar:11336/140140instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:57:58.838CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
v-MOKE magnetometry: a solution for devices with fixed electromagnet |
title |
v-MOKE magnetometry: a solution for devices with fixed electromagnet |
spellingShingle |
v-MOKE magnetometry: a solution for devices with fixed electromagnet Bonetto, Fernando Jose FEPT MAGNETIC ANISOTROPIC FILM NANOMAGNETISM SCALING OF IN-PLANE MAGNETIC COMPONENTS SURFACE MAGNETISM VECTORIAL-MOKE |
title_short |
v-MOKE magnetometry: a solution for devices with fixed electromagnet |
title_full |
v-MOKE magnetometry: a solution for devices with fixed electromagnet |
title_fullStr |
v-MOKE magnetometry: a solution for devices with fixed electromagnet |
title_full_unstemmed |
v-MOKE magnetometry: a solution for devices with fixed electromagnet |
title_sort |
v-MOKE magnetometry: a solution for devices with fixed electromagnet |
dc.creator.none.fl_str_mv |
Bonetto, Fernando Jose Tacca, Marcos Sebastian Aguzin, Ana Butera, Alejandro Ricardo Ferron, Julio Bonin, Claudio Julio |
author |
Bonetto, Fernando Jose |
author_facet |
Bonetto, Fernando Jose Tacca, Marcos Sebastian Aguzin, Ana Butera, Alejandro Ricardo Ferron, Julio Bonin, Claudio Julio |
author_role |
author |
author2 |
Tacca, Marcos Sebastian Aguzin, Ana Butera, Alejandro Ricardo Ferron, Julio Bonin, Claudio Julio |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
FEPT MAGNETIC ANISOTROPIC FILM NANOMAGNETISM SCALING OF IN-PLANE MAGNETIC COMPONENTS SURFACE MAGNETISM VECTORIAL-MOKE |
topic |
FEPT MAGNETIC ANISOTROPIC FILM NANOMAGNETISM SCALING OF IN-PLANE MAGNETIC COMPONENTS SURFACE MAGNETISM VECTORIAL-MOKE |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
We introduce a novel method aimed to obtain the scale factor between in-plane magnetization components, indispensable for vectorial-magneto-optic Kerr effect (v-MOKE) experiments, convenient for experimental setups where it is difficult or unfeasible to rotate the electromagnet. Unlike the original method, in our proposal the electromagnet (and all other optical components) are fixed, extending in this way the possibility to implement v-MOKE magnetometry. Two films, FePt 9 and 100 nm thickness, were used as sample probes, presenting in-plane magnetic uniaxial anisotropy and in-plane magnetic isotropy, respectively. All experiments were carried out at room temperature and employing an home-made MOKE system. We also introduce a closed mathematical expression for the scale factor linking both magnetization components in terms of experimental and sample dependent parameters. Fil: Bonetto, Fernando Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina Fil: Tacca, Marcos Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina Fil: Aguzin, Ana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina Fil: Butera, Alejandro Ricardo. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro.; Argentina Fil: Ferron, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina Fil: Bonin, Claudio Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Física del Litoral. Universidad Nacional del Litoral. Instituto de Física del Litoral; Argentina |
description |
We introduce a novel method aimed to obtain the scale factor between in-plane magnetization components, indispensable for vectorial-magneto-optic Kerr effect (v-MOKE) experiments, convenient for experimental setups where it is difficult or unfeasible to rotate the electromagnet. Unlike the original method, in our proposal the electromagnet (and all other optical components) are fixed, extending in this way the possibility to implement v-MOKE magnetometry. Two films, FePt 9 and 100 nm thickness, were used as sample probes, presenting in-plane magnetic uniaxial anisotropy and in-plane magnetic isotropy, respectively. All experiments were carried out at room temperature and employing an home-made MOKE system. We also introduce a closed mathematical expression for the scale factor linking both magnetization components in terms of experimental and sample dependent parameters. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-05 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/140140 Bonetto, Fernando Jose; Tacca, Marcos Sebastian; Aguzin, Ana; Butera, Alejandro Ricardo; Ferron, Julio; et al.; v-MOKE magnetometry: a solution for devices with fixed electromagnet; IOP Publishing; Measurement Science & Technology (print); 31; 11; 5-2020; 1-6 0957-0233 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/140140 |
identifier_str_mv |
Bonetto, Fernando Jose; Tacca, Marcos Sebastian; Aguzin, Ana; Butera, Alejandro Ricardo; Ferron, Julio; et al.; v-MOKE magnetometry: a solution for devices with fixed electromagnet; IOP Publishing; Measurement Science & Technology (print); 31; 11; 5-2020; 1-6 0957-0233 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1361-6501/ab9411 info:eu-repo/semantics/altIdentifier/doi/10.1088/1361-6501/ab9411 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
IOP Publishing |
publisher.none.fl_str_mv |
IOP Publishing |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613731277864960 |
score |
13.070432 |