Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers

Autores
Gomez Jimenez, Roderick A.; Oggier, German Gustavo; Porras Fernandez, David; Balda, Juan Carlos
Año de publicación
2022
Idioma
inglés
Tipo de recurso
documento de conferencia
Estado
versión publicada
Descripción
This paper presents the analysis of the current resonances on medium-voltage, medium-frequency transformers due to the parasitic capacitances of the windings. Converter performance is affected by these high-frequency current resonances; therefore, the winding arrangement of high-voltage high-turns ratio transformers must be carefully considered during the building process. Three different windings arrangements are built for a 5-kV-to-400-V, 10-kHz transformer for a high-power dual-active bridge (DAB) converter. The open-circuit and short-circuit impedance response of the three windings is compared. Experimental results include an open-circuit test on each of the three different winding arrangements and a 10 kW load test to illustrate the effect of the parasitic capacitances.
Fil: Gomez Jimenez, Roderick A.. University of Arkansas; Estados Unidos
Fil: Oggier, German Gustavo. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Instituto de Investigaciones en Tecnologías Energéticas y Materiales Avanzados. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Tecnologías Energéticas y Materiales Avanzados; Argentina
Fil: Porras Fernandez, David. University of Arkansas; Estados Unidos
Fil: Balda, Juan Carlos. University of Arkansas; Estados Unidos
37th Annual IEEE Applied Power Electronics Conference and Exposition (APEC)
Estados Unidos
Institute of Electrical and Electronics Engineers
Materia
NANOCRYSTALLINE TRANSFORMER
MEDIUM-FREQUENCY TRANSFORMER
CURRENT RESONANT
HIGH-VOLTAGE TRANSFORMER
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/219873

id CONICETDig_93f0a30e291c74ed2bae7dbb9a07304f
oai_identifier_str oai:ri.conicet.gov.ar:11336/219873
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency TransformersGomez Jimenez, Roderick A.Oggier, German GustavoPorras Fernandez, DavidBalda, Juan CarlosNANOCRYSTALLINE TRANSFORMERMEDIUM-FREQUENCY TRANSFORMERCURRENT RESONANTHIGH-VOLTAGE TRANSFORMERhttps://purl.org/becyt/ford/2.2https://purl.org/becyt/ford/2This paper presents the analysis of the current resonances on medium-voltage, medium-frequency transformers due to the parasitic capacitances of the windings. Converter performance is affected by these high-frequency current resonances; therefore, the winding arrangement of high-voltage high-turns ratio transformers must be carefully considered during the building process. Three different windings arrangements are built for a 5-kV-to-400-V, 10-kHz transformer for a high-power dual-active bridge (DAB) converter. The open-circuit and short-circuit impedance response of the three windings is compared. Experimental results include an open-circuit test on each of the three different winding arrangements and a 10 kW load test to illustrate the effect of the parasitic capacitances.Fil: Gomez Jimenez, Roderick A.. University of Arkansas; Estados UnidosFil: Oggier, German Gustavo. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Instituto de Investigaciones en Tecnologías Energéticas y Materiales Avanzados. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Tecnologías Energéticas y Materiales Avanzados; ArgentinaFil: Porras Fernandez, David. University of Arkansas; Estados UnidosFil: Balda, Juan Carlos. University of Arkansas; Estados Unidos37th Annual IEEE Applied Power Electronics Conference and Exposition (APEC)Estados UnidosInstitute of Electrical and Electronics EngineersInstitute of Electrical and Electronics Engineers2022info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectCongresoBookhttp://purl.org/coar/resource_type/c_5794info:ar-repo/semantics/documentoDeConferenciaapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/219873Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers; 37th Annual IEEE Applied Power Electronics Conference and Exposition (APEC); Estados Unidos; 2022; 939-943978-1-6654-0688-8CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://ieeexplore.ieee.org/document/9773427info:eu-repo/semantics/altIdentifier/doi/10.1109/APEC43599.2022.9773427Internacionalinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:57:35Zoai:ri.conicet.gov.ar:11336/219873instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:57:36.015CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
title Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
spellingShingle Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
Gomez Jimenez, Roderick A.
NANOCRYSTALLINE TRANSFORMER
MEDIUM-FREQUENCY TRANSFORMER
CURRENT RESONANT
HIGH-VOLTAGE TRANSFORMER
title_short Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
title_full Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
title_fullStr Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
title_full_unstemmed Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
title_sort Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers
dc.creator.none.fl_str_mv Gomez Jimenez, Roderick A.
Oggier, German Gustavo
Porras Fernandez, David
Balda, Juan Carlos
author Gomez Jimenez, Roderick A.
author_facet Gomez Jimenez, Roderick A.
Oggier, German Gustavo
Porras Fernandez, David
Balda, Juan Carlos
author_role author
author2 Oggier, German Gustavo
Porras Fernandez, David
Balda, Juan Carlos
author2_role author
author
author
dc.subject.none.fl_str_mv NANOCRYSTALLINE TRANSFORMER
MEDIUM-FREQUENCY TRANSFORMER
CURRENT RESONANT
HIGH-VOLTAGE TRANSFORMER
topic NANOCRYSTALLINE TRANSFORMER
MEDIUM-FREQUENCY TRANSFORMER
CURRENT RESONANT
HIGH-VOLTAGE TRANSFORMER
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.2
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv This paper presents the analysis of the current resonances on medium-voltage, medium-frequency transformers due to the parasitic capacitances of the windings. Converter performance is affected by these high-frequency current resonances; therefore, the winding arrangement of high-voltage high-turns ratio transformers must be carefully considered during the building process. Three different windings arrangements are built for a 5-kV-to-400-V, 10-kHz transformer for a high-power dual-active bridge (DAB) converter. The open-circuit and short-circuit impedance response of the three windings is compared. Experimental results include an open-circuit test on each of the three different winding arrangements and a 10 kW load test to illustrate the effect of the parasitic capacitances.
Fil: Gomez Jimenez, Roderick A.. University of Arkansas; Estados Unidos
Fil: Oggier, German Gustavo. Universidad Nacional de Río Cuarto. Facultad de Ciencias Exactas Fisicoquímicas y Naturales. Instituto de Investigaciones en Tecnologías Energéticas y Materiales Avanzados. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Tecnologías Energéticas y Materiales Avanzados; Argentina
Fil: Porras Fernandez, David. University of Arkansas; Estados Unidos
Fil: Balda, Juan Carlos. University of Arkansas; Estados Unidos
37th Annual IEEE Applied Power Electronics Conference and Exposition (APEC)
Estados Unidos
Institute of Electrical and Electronics Engineers
description This paper presents the analysis of the current resonances on medium-voltage, medium-frequency transformers due to the parasitic capacitances of the windings. Converter performance is affected by these high-frequency current resonances; therefore, the winding arrangement of high-voltage high-turns ratio transformers must be carefully considered during the building process. Three different windings arrangements are built for a 5-kV-to-400-V, 10-kHz transformer for a high-power dual-active bridge (DAB) converter. The open-circuit and short-circuit impedance response of the three windings is compared. Experimental results include an open-circuit test on each of the three different winding arrangements and a 10 kW load test to illustrate the effect of the parasitic capacitances.
publishDate 2022
dc.date.none.fl_str_mv 2022
dc.type.none.fl_str_mv info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/conferenceObject
Congreso
Book
http://purl.org/coar/resource_type/c_5794
info:ar-repo/semantics/documentoDeConferencia
status_str publishedVersion
format conferenceObject
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/219873
Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers; 37th Annual IEEE Applied Power Electronics Conference and Exposition (APEC); Estados Unidos; 2022; 939-943
978-1-6654-0688-8
CONICET Digital
CONICET
url http://hdl.handle.net/11336/219873
identifier_str_mv Analysis of Current Resonances due to Winding Parasitic Capacitances in Medium-Voltage Medium-Frequency Transformers; 37th Annual IEEE Applied Power Electronics Conference and Exposition (APEC); Estados Unidos; 2022; 939-943
978-1-6654-0688-8
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://ieeexplore.ieee.org/document/9773427
info:eu-repo/semantics/altIdentifier/doi/10.1109/APEC43599.2022.9773427
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.coverage.none.fl_str_mv Internacional
dc.publisher.none.fl_str_mv Institute of Electrical and Electronics Engineers
publisher.none.fl_str_mv Institute of Electrical and Electronics Engineers
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842269471527403520
score 13.13397