Real-time reaction monitoring by probe electrospray ionization mass spectrometry
- Autores
- Yu, Zhan; Chen, Lee Chuin; Erra Balsells, Rosa; Nonami, Hiroshi; Hiraoka, Kenzo
- Año de publicación
- 2010
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI-MS was used to monitor some biological and chemical reactions in real-time, such as acid-induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI-MS, time-resolved mass spectra and ion chromatograms can be obtained reproducibly. Real-time PESI-MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI-MS can be considered as a potential tool for real-time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption.
Fil: Yu, Zhan. Shenyang Normal University; China. University of Yamanashi; Japón
Fil: Chen, Lee Chuin. University of Yamanashi; Japón
Fil: Erra Balsells, Rosa. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Centro de Investigaciones en Hidratos de Carbono. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Centro de Investigaciones en Hidratos de Carbono; Argentina
Fil: Nonami, Hiroshi. Ehime University; Japón
Fil: Hiraoka, Kenzo. University of Yamanashi; Japón - Materia
-
Mass spectrometry
PESI-MS
PESI-MS reaction monitoring
PESI-MS at real time - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/99310
Ver los metadatos del registro completo
| id |
CONICETDig_92a0b331259d7dc6481ad3609a06254a |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/99310 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
Real-time reaction monitoring by probe electrospray ionization mass spectrometryYu, ZhanChen, Lee ChuinErra Balsells, RosaNonami, HiroshiHiraoka, KenzoMass spectrometryPESI-MSPESI-MS reaction monitoringPESI-MS at real timehttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI-MS was used to monitor some biological and chemical reactions in real-time, such as acid-induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI-MS, time-resolved mass spectra and ion chromatograms can be obtained reproducibly. Real-time PESI-MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI-MS can be considered as a potential tool for real-time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption.Fil: Yu, Zhan. Shenyang Normal University; China. University of Yamanashi; JapónFil: Chen, Lee Chuin. University of Yamanashi; JapónFil: Erra Balsells, Rosa. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Centro de Investigaciones en Hidratos de Carbono. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Centro de Investigaciones en Hidratos de Carbono; ArgentinaFil: Nonami, Hiroshi. Ehime University; JapónFil: Hiraoka, Kenzo. University of Yamanashi; JapónJohn Wiley & Sons Ltd2010-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/99310Yu, Zhan; Chen, Lee Chuin; Erra Balsells, Rosa; Nonami, Hiroshi; Hiraoka, Kenzo; Real-time reaction monitoring by probe electrospray ionization mass spectrometry; John Wiley & Sons Ltd; Rapid Communications in Mass Spectrometry; 24; 11; 6-2010; 1507-15130951-4198CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/10.1002/rcm.4556info:eu-repo/semantics/altIdentifier/doi/10.1002/rcm.4556info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-29T11:59:44Zoai:ri.conicet.gov.ar:11336/99310instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-29 11:59:45.061CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry |
| title |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry |
| spellingShingle |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry Yu, Zhan Mass spectrometry PESI-MS PESI-MS reaction monitoring PESI-MS at real time |
| title_short |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry |
| title_full |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry |
| title_fullStr |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry |
| title_full_unstemmed |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry |
| title_sort |
Real-time reaction monitoring by probe electrospray ionization mass spectrometry |
| dc.creator.none.fl_str_mv |
Yu, Zhan Chen, Lee Chuin Erra Balsells, Rosa Nonami, Hiroshi Hiraoka, Kenzo |
| author |
Yu, Zhan |
| author_facet |
Yu, Zhan Chen, Lee Chuin Erra Balsells, Rosa Nonami, Hiroshi Hiraoka, Kenzo |
| author_role |
author |
| author2 |
Chen, Lee Chuin Erra Balsells, Rosa Nonami, Hiroshi Hiraoka, Kenzo |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
Mass spectrometry PESI-MS PESI-MS reaction monitoring PESI-MS at real time |
| topic |
Mass spectrometry PESI-MS PESI-MS reaction monitoring PESI-MS at real time |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
| dc.description.none.fl_txt_mv |
Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI-MS was used to monitor some biological and chemical reactions in real-time, such as acid-induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI-MS, time-resolved mass spectra and ion chromatograms can be obtained reproducibly. Real-time PESI-MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI-MS can be considered as a potential tool for real-time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption. Fil: Yu, Zhan. Shenyang Normal University; China. University of Yamanashi; Japón Fil: Chen, Lee Chuin. University of Yamanashi; Japón Fil: Erra Balsells, Rosa. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Centro de Investigaciones en Hidratos de Carbono. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Centro de Investigaciones en Hidratos de Carbono; Argentina Fil: Nonami, Hiroshi. Ehime University; Japón Fil: Hiraoka, Kenzo. University of Yamanashi; Japón |
| description |
Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI-MS was used to monitor some biological and chemical reactions in real-time, such as acid-induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI-MS, time-resolved mass spectra and ion chromatograms can be obtained reproducibly. Real-time PESI-MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI-MS can be considered as a potential tool for real-time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010-06 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/99310 Yu, Zhan; Chen, Lee Chuin; Erra Balsells, Rosa; Nonami, Hiroshi; Hiraoka, Kenzo; Real-time reaction monitoring by probe electrospray ionization mass spectrometry; John Wiley & Sons Ltd; Rapid Communications in Mass Spectrometry; 24; 11; 6-2010; 1507-1513 0951-4198 CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/99310 |
| identifier_str_mv |
Yu, Zhan; Chen, Lee Chuin; Erra Balsells, Rosa; Nonami, Hiroshi; Hiraoka, Kenzo; Real-time reaction monitoring by probe electrospray ionization mass spectrometry; John Wiley & Sons Ltd; Rapid Communications in Mass Spectrometry; 24; 11; 6-2010; 1507-1513 0951-4198 CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/10.1002/rcm.4556 info:eu-repo/semantics/altIdentifier/doi/10.1002/rcm.4556 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
John Wiley & Sons Ltd |
| publisher.none.fl_str_mv |
John Wiley & Sons Ltd |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1847426738786664448 |
| score |
13.10058 |