Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation
- Autores
- Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio César; Campos, Juan
- Año de publicación
- 2011
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device.
Fil: Peinado, Alba. Universidad Autonoma de Barcelona. Facultad de Física; España
Fil: Lizana, Ángel. Universidad Autonoma de Barcelona. Facultad de Física; España
Fil: Vidal, Josep. Universidad Autonoma de Barcelona. Facultad de Física; España
Fil: Iemmi, Claudio César. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Campos, Juan. Universidad Autonoma de Barcelona. Facultad de Física; España - Materia
-
Polarimetry
Ellipsometry And Polarimetry
Liquid Crystal Devices - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/68316
Ver los metadatos del registro completo
id |
CONICETDig_9139780f92ed73a97e94ac6c1e863d86 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/68316 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagationPeinado, AlbaLizana, ÁngelVidal, JosepIemmi, Claudio CésarCampos, JuanPolarimetryEllipsometry And PolarimetryLiquid Crystal Deviceshttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device.Fil: Peinado, Alba. Universidad Autonoma de Barcelona. Facultad de Física; EspañaFil: Lizana, Ángel. Universidad Autonoma de Barcelona. Facultad de Física; EspañaFil: Vidal, Josep. Universidad Autonoma de Barcelona. Facultad de Física; EspañaFil: Iemmi, Claudio César. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Campos, Juan. Universidad Autonoma de Barcelona. Facultad de Física; EspañaOptical Society of America2011-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/68316Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio César; Campos, Juan; Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation; Optical Society of America; Applied Optics; 50; 28; 10-2011; 5437-54451539-4522CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1364/AO.50.005437info:eu-repo/semantics/altIdentifier/url/https://www.osapublishing.org/ao/abstract.cfm?uri=ao-50-28-5437info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:10:17Zoai:ri.conicet.gov.ar:11336/68316instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:10:18.063CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
spellingShingle |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation Peinado, Alba Polarimetry Ellipsometry And Polarimetry Liquid Crystal Devices |
title_short |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_full |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_fullStr |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_full_unstemmed |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
title_sort |
Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation |
dc.creator.none.fl_str_mv |
Peinado, Alba Lizana, Ángel Vidal, Josep Iemmi, Claudio César Campos, Juan |
author |
Peinado, Alba |
author_facet |
Peinado, Alba Lizana, Ángel Vidal, Josep Iemmi, Claudio César Campos, Juan |
author_role |
author |
author2 |
Lizana, Ángel Vidal, Josep Iemmi, Claudio César Campos, Juan |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
Polarimetry Ellipsometry And Polarimetry Liquid Crystal Devices |
topic |
Polarimetry Ellipsometry And Polarimetry Liquid Crystal Devices |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device. Fil: Peinado, Alba. Universidad Autonoma de Barcelona. Facultad de Física; España Fil: Lizana, Ángel. Universidad Autonoma de Barcelona. Facultad de Física; España Fil: Vidal, Josep. Universidad Autonoma de Barcelona. Facultad de Física; España Fil: Iemmi, Claudio César. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Campos, Juan. Universidad Autonoma de Barcelona. Facultad de Física; España |
description |
This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-10 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/68316 Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio César; Campos, Juan; Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation; Optical Society of America; Applied Optics; 50; 28; 10-2011; 5437-5445 1539-4522 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/68316 |
identifier_str_mv |
Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio César; Campos, Juan; Optimized Stokes polarimeters based on a single twisted nematic liquid-crystal device for the minimization of noise propagation; Optical Society of America; Applied Optics; 50; 28; 10-2011; 5437-5445 1539-4522 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1364/AO.50.005437 info:eu-repo/semantics/altIdentifier/url/https://www.osapublishing.org/ao/abstract.cfm?uri=ao-50-28-5437 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Optical Society of America |
publisher.none.fl_str_mv |
Optical Society of America |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613990593855488 |
score |
13.070432 |