Optimization and performance criteria of a Stokes polarimeter based on two variable retarders
- Autores
- Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio Cesar; Campos, Juan
- Año de publicación
- 2010
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- In this paper we present the analysis, optimization and implementation of several Stokes polarimeter configurations based on a setup including two variable retarders. The polarimeter analysis is based on the Mueller-Stokes formalism, and as a consequence, it is suitable to deal with depolarized light. Complete Stokes polarimeters are optimized by minimizing the amplification of simulated errors into the final solution. Different indicators useful to achieve this aim, as the condition number or the equally weighted variance, are compared in this paper. Moreover, some of the optimized polarimeters are experimentally implemented and it is studied the influence of small deviations from the theoretical ones on the amplification of the Stokes component error. In addition, the benefit of using incomplete polarimeters, when detecting specific ranges of states of polarization, is discussed
Fil: Peinado, Alba. Universitat Autonoma de Barcelona; España
Fil: Lizana, Ángel. Universitat Autonoma de Barcelona; España
Fil: Vidal, Josep. Universitat Autonoma de Barcelona; España. ALBA Synchrotron Light Source Facility; España
Fil: Iemmi, Claudio Cesar. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Campos, Juan. Universitat Autonoma de Barcelona; España - Materia
-
Polarimetry
Ellipsometry and polarimetry
Liquid crystal devices - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/16378
Ver los metadatos del registro completo
| id |
CONICETDig_1c5f550f37062f911291150227bdc74e |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/16378 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
Optimization and performance criteria of a Stokes polarimeter based on two variable retardersPeinado, AlbaLizana, ÁngelVidal, JosepIemmi, Claudio CesarCampos, JuanPolarimetryEllipsometry and polarimetryLiquid crystal deviceshttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1In this paper we present the analysis, optimization and implementation of several Stokes polarimeter configurations based on a setup including two variable retarders. The polarimeter analysis is based on the Mueller-Stokes formalism, and as a consequence, it is suitable to deal with depolarized light. Complete Stokes polarimeters are optimized by minimizing the amplification of simulated errors into the final solution. Different indicators useful to achieve this aim, as the condition number or the equally weighted variance, are compared in this paper. Moreover, some of the optimized polarimeters are experimentally implemented and it is studied the influence of small deviations from the theoretical ones on the amplification of the Stokes component error. In addition, the benefit of using incomplete polarimeters, when detecting specific ranges of states of polarization, is discussedFil: Peinado, Alba. Universitat Autonoma de Barcelona; EspañaFil: Lizana, Ángel. Universitat Autonoma de Barcelona; EspañaFil: Vidal, Josep. Universitat Autonoma de Barcelona; España. ALBA Synchrotron Light Source Facility; EspañaFil: Iemmi, Claudio Cesar. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Campos, Juan. Universitat Autonoma de Barcelona; EspañaOptical Society Of America2010-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/16378Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio Cesar; Campos, Juan; Optimization and performance criteria of a Stokes polarimeter based on two variable retarders; Optical Society Of America; Optics Express; 18; 10; 4-2010; 9815-98301094-4087enginfo:eu-repo/semantics/altIdentifier/doi/10.1364/OE.18.009815info:eu-repo/semantics/altIdentifier/url/https://www.osapublishing.org/oe/abstract.cfm?uri=oe-18-10-9815info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-22T11:23:54Zoai:ri.conicet.gov.ar:11336/16378instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-22 11:23:54.822CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders |
| title |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders |
| spellingShingle |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders Peinado, Alba Polarimetry Ellipsometry and polarimetry Liquid crystal devices |
| title_short |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders |
| title_full |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders |
| title_fullStr |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders |
| title_full_unstemmed |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders |
| title_sort |
Optimization and performance criteria of a Stokes polarimeter based on two variable retarders |
| dc.creator.none.fl_str_mv |
Peinado, Alba Lizana, Ángel Vidal, Josep Iemmi, Claudio Cesar Campos, Juan |
| author |
Peinado, Alba |
| author_facet |
Peinado, Alba Lizana, Ángel Vidal, Josep Iemmi, Claudio Cesar Campos, Juan |
| author_role |
author |
| author2 |
Lizana, Ángel Vidal, Josep Iemmi, Claudio Cesar Campos, Juan |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
Polarimetry Ellipsometry and polarimetry Liquid crystal devices |
| topic |
Polarimetry Ellipsometry and polarimetry Liquid crystal devices |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
| dc.description.none.fl_txt_mv |
In this paper we present the analysis, optimization and implementation of several Stokes polarimeter configurations based on a setup including two variable retarders. The polarimeter analysis is based on the Mueller-Stokes formalism, and as a consequence, it is suitable to deal with depolarized light. Complete Stokes polarimeters are optimized by minimizing the amplification of simulated errors into the final solution. Different indicators useful to achieve this aim, as the condition number or the equally weighted variance, are compared in this paper. Moreover, some of the optimized polarimeters are experimentally implemented and it is studied the influence of small deviations from the theoretical ones on the amplification of the Stokes component error. In addition, the benefit of using incomplete polarimeters, when detecting specific ranges of states of polarization, is discussed Fil: Peinado, Alba. Universitat Autonoma de Barcelona; España Fil: Lizana, Ángel. Universitat Autonoma de Barcelona; España Fil: Vidal, Josep. Universitat Autonoma de Barcelona; España. ALBA Synchrotron Light Source Facility; España Fil: Iemmi, Claudio Cesar. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Campos, Juan. Universitat Autonoma de Barcelona; España |
| description |
In this paper we present the analysis, optimization and implementation of several Stokes polarimeter configurations based on a setup including two variable retarders. The polarimeter analysis is based on the Mueller-Stokes formalism, and as a consequence, it is suitable to deal with depolarized light. Complete Stokes polarimeters are optimized by minimizing the amplification of simulated errors into the final solution. Different indicators useful to achieve this aim, as the condition number or the equally weighted variance, are compared in this paper. Moreover, some of the optimized polarimeters are experimentally implemented and it is studied the influence of small deviations from the theoretical ones on the amplification of the Stokes component error. In addition, the benefit of using incomplete polarimeters, when detecting specific ranges of states of polarization, is discussed |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010-04 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/16378 Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio Cesar; Campos, Juan; Optimization and performance criteria of a Stokes polarimeter based on two variable retarders; Optical Society Of America; Optics Express; 18; 10; 4-2010; 9815-9830 1094-4087 |
| url |
http://hdl.handle.net/11336/16378 |
| identifier_str_mv |
Peinado, Alba; Lizana, Ángel; Vidal, Josep; Iemmi, Claudio Cesar; Campos, Juan; Optimization and performance criteria of a Stokes polarimeter based on two variable retarders; Optical Society Of America; Optics Express; 18; 10; 4-2010; 9815-9830 1094-4087 |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1364/OE.18.009815 info:eu-repo/semantics/altIdentifier/url/https://www.osapublishing.org/oe/abstract.cfm?uri=oe-18-10-9815 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Optical Society Of America |
| publisher.none.fl_str_mv |
Optical Society Of America |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1846781772584452096 |
| score |
12.982451 |