Cloud-point extraction/preconcentration on-line flow injection method for mercury determination
- Autores
- Garrido, Mariano Enrique; Di Nezio, Maria Susana; Lista, Adriana Guillermina; Palomeque, Miriam Edid; Fernández Band, Beatriz Susana
- Año de publicación
- 2004
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A cloud-point extraction/preconcentration (CPE/P) step is incorporated on-line into a flow injection system which is used to determine low levels of Hg(II) added to natural water samples. The analyte is complexed with dithizone. A solid reagent column (SRC) is used to prepare the reagent on-line by using 5% (v/v) Triton X-100 solution as solvent. The CPE/P is carried out by using the non-ionic surfactant Triton X-100. After obtaining the cloud-point on-line, the surfactant-rich phase containing the complex is collected in a mini column packed with cotton wool. Then, a hot water stream is passed through the column to elute the complex and the absorbance is measured at 500nm. All the flow and chemical variables are optimized and the enhancement factor for the system is estimated. The calibration is linear over the range 0.05-0.5μgml -1, the R.S.D. is 4.8%, the limit of detection (signal:noise = 3) is 0.014μgml-1 and the sample throughput is 30h-1. An open/closed system is used to eliminate the interference of iron(III). © 2003 Elsevier B.V. All rights reserved.
Fil: Garrido, Mariano Enrique. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina
Fil: Di Nezio, Maria Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina
Fil: Lista, Adriana Guillermina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina
Fil: Palomeque, Miriam Edid. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina
Fil: Fernández Band, Beatriz Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina - Materia
-
CLOUD-POINT
MERCURY
ON-LINE EXTRACTION - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/96904
Ver los metadatos del registro completo
id |
CONICETDig_88acfa6f855b708b64d68d3e197642cb |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/96904 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determinationGarrido, Mariano EnriqueDi Nezio, Maria SusanaLista, Adriana GuillerminaPalomeque, Miriam EdidFernández Band, Beatriz SusanaCLOUD-POINTMERCURYON-LINE EXTRACTIONhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1A cloud-point extraction/preconcentration (CPE/P) step is incorporated on-line into a flow injection system which is used to determine low levels of Hg(II) added to natural water samples. The analyte is complexed with dithizone. A solid reagent column (SRC) is used to prepare the reagent on-line by using 5% (v/v) Triton X-100 solution as solvent. The CPE/P is carried out by using the non-ionic surfactant Triton X-100. After obtaining the cloud-point on-line, the surfactant-rich phase containing the complex is collected in a mini column packed with cotton wool. Then, a hot water stream is passed through the column to elute the complex and the absorbance is measured at 500nm. All the flow and chemical variables are optimized and the enhancement factor for the system is estimated. The calibration is linear over the range 0.05-0.5μgml -1, the R.S.D. is 4.8%, the limit of detection (signal:noise = 3) is 0.014μgml-1 and the sample throughput is 30h-1. An open/closed system is used to eliminate the interference of iron(III). © 2003 Elsevier B.V. All rights reserved.Fil: Garrido, Mariano Enrique. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; ArgentinaFil: Di Nezio, Maria Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; ArgentinaFil: Lista, Adriana Guillermina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; ArgentinaFil: Palomeque, Miriam Edid. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; ArgentinaFil: Fernández Band, Beatriz Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; ArgentinaElsevier Science2004-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/96904Garrido, Mariano Enrique; Di Nezio, Maria Susana; Lista, Adriana Guillermina; Palomeque, Miriam Edid; Fernández Band, Beatriz Susana; Cloud-point extraction/preconcentration on-line flow injection method for mercury determination; Elsevier Science; Analytica Chimica Acta; 502; 2; 1-2004; 173-1770003-2670CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003267003013114info:eu-repo/semantics/altIdentifier/doi/10.1016/j.aca.2003.09.070info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:46:04Zoai:ri.conicet.gov.ar:11336/96904instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:46:04.655CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination |
title |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination |
spellingShingle |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination Garrido, Mariano Enrique CLOUD-POINT MERCURY ON-LINE EXTRACTION |
title_short |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination |
title_full |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination |
title_fullStr |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination |
title_full_unstemmed |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination |
title_sort |
Cloud-point extraction/preconcentration on-line flow injection method for mercury determination |
dc.creator.none.fl_str_mv |
Garrido, Mariano Enrique Di Nezio, Maria Susana Lista, Adriana Guillermina Palomeque, Miriam Edid Fernández Band, Beatriz Susana |
author |
Garrido, Mariano Enrique |
author_facet |
Garrido, Mariano Enrique Di Nezio, Maria Susana Lista, Adriana Guillermina Palomeque, Miriam Edid Fernández Band, Beatriz Susana |
author_role |
author |
author2 |
Di Nezio, Maria Susana Lista, Adriana Guillermina Palomeque, Miriam Edid Fernández Band, Beatriz Susana |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
CLOUD-POINT MERCURY ON-LINE EXTRACTION |
topic |
CLOUD-POINT MERCURY ON-LINE EXTRACTION |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
A cloud-point extraction/preconcentration (CPE/P) step is incorporated on-line into a flow injection system which is used to determine low levels of Hg(II) added to natural water samples. The analyte is complexed with dithizone. A solid reagent column (SRC) is used to prepare the reagent on-line by using 5% (v/v) Triton X-100 solution as solvent. The CPE/P is carried out by using the non-ionic surfactant Triton X-100. After obtaining the cloud-point on-line, the surfactant-rich phase containing the complex is collected in a mini column packed with cotton wool. Then, a hot water stream is passed through the column to elute the complex and the absorbance is measured at 500nm. All the flow and chemical variables are optimized and the enhancement factor for the system is estimated. The calibration is linear over the range 0.05-0.5μgml -1, the R.S.D. is 4.8%, the limit of detection (signal:noise = 3) is 0.014μgml-1 and the sample throughput is 30h-1. An open/closed system is used to eliminate the interference of iron(III). © 2003 Elsevier B.V. All rights reserved. Fil: Garrido, Mariano Enrique. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina Fil: Di Nezio, Maria Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina Fil: Lista, Adriana Guillermina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina Fil: Palomeque, Miriam Edid. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina Fil: Fernández Band, Beatriz Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina |
description |
A cloud-point extraction/preconcentration (CPE/P) step is incorporated on-line into a flow injection system which is used to determine low levels of Hg(II) added to natural water samples. The analyte is complexed with dithizone. A solid reagent column (SRC) is used to prepare the reagent on-line by using 5% (v/v) Triton X-100 solution as solvent. The CPE/P is carried out by using the non-ionic surfactant Triton X-100. After obtaining the cloud-point on-line, the surfactant-rich phase containing the complex is collected in a mini column packed with cotton wool. Then, a hot water stream is passed through the column to elute the complex and the absorbance is measured at 500nm. All the flow and chemical variables are optimized and the enhancement factor for the system is estimated. The calibration is linear over the range 0.05-0.5μgml -1, the R.S.D. is 4.8%, the limit of detection (signal:noise = 3) is 0.014μgml-1 and the sample throughput is 30h-1. An open/closed system is used to eliminate the interference of iron(III). © 2003 Elsevier B.V. All rights reserved. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/96904 Garrido, Mariano Enrique; Di Nezio, Maria Susana; Lista, Adriana Guillermina; Palomeque, Miriam Edid; Fernández Band, Beatriz Susana; Cloud-point extraction/preconcentration on-line flow injection method for mercury determination; Elsevier Science; Analytica Chimica Acta; 502; 2; 1-2004; 173-177 0003-2670 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/96904 |
identifier_str_mv |
Garrido, Mariano Enrique; Di Nezio, Maria Susana; Lista, Adriana Guillermina; Palomeque, Miriam Edid; Fernández Band, Beatriz Susana; Cloud-point extraction/preconcentration on-line flow injection method for mercury determination; Elsevier Science; Analytica Chimica Acta; 502; 2; 1-2004; 173-177 0003-2670 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003267003013114 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.aca.2003.09.070 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842268772512038912 |
score |
13.13397 |