Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation

Autores
Molina, Pablo Fernando; Sommer, M.; Kattner, F.; Henniger, J.
Año de publicación
2013
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
In this work the feasibility of using Y2O3:Eu as a fiberoptic dosimetry (FOD) probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the radioluminescence (RL) signal after repeated use and RL emission spectrum of a Y2O3:Eu-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage depth dose curve (PDD) in a water phantom under 60Co irradiation, and its performance has been compared to that of a standard ionization chamber.
Fil: Molina, Pablo Fernando. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil; Argentina
Fil: Sommer, M.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; Alemania
Fil: Kattner, F.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; Alemania
Fil: Henniger, J.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; Alemania
Materia
Radioluminescence
Yttrium-Oxide
Real-Time Dosimetry
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/6968

id CONICETDig_70ce640ab884b51fe3f724551bec43e9
oai_identifier_str oai:ri.conicet.gov.ar:11336/6968
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiationMolina, Pablo FernandoSommer, M.Kattner, F.Henniger, J.RadioluminescenceYttrium-OxideReal-Time Dosimetryhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1In this work the feasibility of using Y2O3:Eu as a fiberoptic dosimetry (FOD) probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the radioluminescence (RL) signal after repeated use and RL emission spectrum of a Y2O3:Eu-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage depth dose curve (PDD) in a water phantom under 60Co irradiation, and its performance has been compared to that of a standard ionization chamber.Fil: Molina, Pablo Fernando. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil; ArgentinaFil: Sommer, M.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; AlemaniaFil: Kattner, F.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; AlemaniaFil: Henniger, J.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; AlemaniaElsevier2013-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/6968Molina, Pablo Fernando; Sommer, M.; Kattner, F.; Henniger, J.; Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation; Elsevier; Radiation Measurements; 56; 1-2013; 338-3411350-4487enginfo:eu-repo/semantics/altIdentifier/doi/info:eu-repo/semantics/altIdentifier/doi/10.1016/j.radmeas.2013.01.031info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S1350448713000541info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:41:53Zoai:ri.conicet.gov.ar:11336/6968instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:41:53.768CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
title Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
spellingShingle Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
Molina, Pablo Fernando
Radioluminescence
Yttrium-Oxide
Real-Time Dosimetry
title_short Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
title_full Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
title_fullStr Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
title_full_unstemmed Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
title_sort Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation
dc.creator.none.fl_str_mv Molina, Pablo Fernando
Sommer, M.
Kattner, F.
Henniger, J.
author Molina, Pablo Fernando
author_facet Molina, Pablo Fernando
Sommer, M.
Kattner, F.
Henniger, J.
author_role author
author2 Sommer, M.
Kattner, F.
Henniger, J.
author2_role author
author
author
dc.subject.none.fl_str_mv Radioluminescence
Yttrium-Oxide
Real-Time Dosimetry
topic Radioluminescence
Yttrium-Oxide
Real-Time Dosimetry
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv In this work the feasibility of using Y2O3:Eu as a fiberoptic dosimetry (FOD) probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the radioluminescence (RL) signal after repeated use and RL emission spectrum of a Y2O3:Eu-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage depth dose curve (PDD) in a water phantom under 60Co irradiation, and its performance has been compared to that of a standard ionization chamber.
Fil: Molina, Pablo Fernando. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil; Argentina
Fil: Sommer, M.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; Alemania
Fil: Kattner, F.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; Alemania
Fil: Henniger, J.. Dresden University of Technology. Institute of Nuclear and Particle Physics. Radiation Physics Group; Alemania
description In this work the feasibility of using Y2O3:Eu as a fiberoptic dosimetry (FOD) probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the radioluminescence (RL) signal after repeated use and RL emission spectrum of a Y2O3:Eu-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage depth dose curve (PDD) in a water phantom under 60Co irradiation, and its performance has been compared to that of a standard ionization chamber.
publishDate 2013
dc.date.none.fl_str_mv 2013-01
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/6968
Molina, Pablo Fernando; Sommer, M.; Kattner, F.; Henniger, J.; Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation; Elsevier; Radiation Measurements; 56; 1-2013; 338-341
1350-4487
url http://hdl.handle.net/11336/6968
identifier_str_mv Molina, Pablo Fernando; Sommer, M.; Kattner, F.; Henniger, J.; Response characterization of an Y2O3:Eu-based radioluminescence probe under 60Co irradiation; Elsevier; Radiation Measurements; 56; 1-2013; 338-341
1350-4487
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.radmeas.2013.01.031
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S1350448713000541
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614450753044480
score 13.070432