Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb

Autores
Molina, Pablo Fernando; Prokic, M.; Marcazzo, Salvador Julian; Santiago, Martin Alejo
Año de publicación
2010
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
In this work the feasibility of using Mg2SiO4:Tb as a fiberoptic radioluminescent (RL) dosimetry probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the RL signal after repeated use, the spectrum of the RL emission and the dose-rate response curve of a Mg2SiO4:Tb-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage dose depth curve in a water phantom and its performance has been compared to that of a standard ion chamber. Besides, its absolute RL yield has been compared to that of an RL probe based on the commercial Al2O3:C phosphor.
Fil: Molina, Pablo Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina
Fil: Prokic, M.. Institute of Nuclear Sciences; Serbia
Fil: Marcazzo, Salvador Julian. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Santiago, Martin Alejo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina
Materia
DOSIMETRY
MAGNESIUM ORTHOSILICATE
RADIOLUMINESCENCE
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/96033

id CONICETDig_0bd183b0f76e386fe6f001b3348ae2f2
oai_identifier_str oai:ri.conicet.gov.ar:11336/96033
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:TbMolina, Pablo FernandoProkic, M.Marcazzo, Salvador JulianSantiago, Martin AlejoDOSIMETRYMAGNESIUM ORTHOSILICATERADIOLUMINESCENCEhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1In this work the feasibility of using Mg2SiO4:Tb as a fiberoptic radioluminescent (RL) dosimetry probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the RL signal after repeated use, the spectrum of the RL emission and the dose-rate response curve of a Mg2SiO4:Tb-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage dose depth curve in a water phantom and its performance has been compared to that of a standard ion chamber. Besides, its absolute RL yield has been compared to that of an RL probe based on the commercial Al2O3:C phosphor.Fil: Molina, Pablo Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; ArgentinaFil: Prokic, M.. Institute of Nuclear Sciences; SerbiaFil: Marcazzo, Salvador Julian. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Santiago, Martin Alejo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; ArgentinaPergamon-Elsevier Science Ltd2010-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/96033Molina, Pablo Fernando; Prokic, M.; Marcazzo, Salvador Julian; Santiago, Martin Alejo; Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb; Pergamon-Elsevier Science Ltd; Radiation Measurements; 45; 1; 1-2010; 78-821350-4487CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.radmeas.2009.11.040info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S1350448709003588info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:09:47Zoai:ri.conicet.gov.ar:11336/96033instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:09:48.197CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
title Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
spellingShingle Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
Molina, Pablo Fernando
DOSIMETRY
MAGNESIUM ORTHOSILICATE
RADIOLUMINESCENCE
title_short Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
title_full Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
title_fullStr Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
title_full_unstemmed Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
title_sort Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb
dc.creator.none.fl_str_mv Molina, Pablo Fernando
Prokic, M.
Marcazzo, Salvador Julian
Santiago, Martin Alejo
author Molina, Pablo Fernando
author_facet Molina, Pablo Fernando
Prokic, M.
Marcazzo, Salvador Julian
Santiago, Martin Alejo
author_role author
author2 Prokic, M.
Marcazzo, Salvador Julian
Santiago, Martin Alejo
author2_role author
author
author
dc.subject.none.fl_str_mv DOSIMETRY
MAGNESIUM ORTHOSILICATE
RADIOLUMINESCENCE
topic DOSIMETRY
MAGNESIUM ORTHOSILICATE
RADIOLUMINESCENCE
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv In this work the feasibility of using Mg2SiO4:Tb as a fiberoptic radioluminescent (RL) dosimetry probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the RL signal after repeated use, the spectrum of the RL emission and the dose-rate response curve of a Mg2SiO4:Tb-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage dose depth curve in a water phantom and its performance has been compared to that of a standard ion chamber. Besides, its absolute RL yield has been compared to that of an RL probe based on the commercial Al2O3:C phosphor.
Fil: Molina, Pablo Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina
Fil: Prokic, M.. Institute of Nuclear Sciences; Serbia
Fil: Marcazzo, Salvador Julian. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Santiago, Martin Alejo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina
description In this work the feasibility of using Mg2SiO4:Tb as a fiberoptic radioluminescent (RL) dosimetry probe for real-time dosimetry has been investigated for the first time. In particular, the stability of the RL signal after repeated use, the spectrum of the RL emission and the dose-rate response curve of a Mg2SiO4:Tb-based fiberoptic probe have been determined. The probe has been also used to obtain a percentage dose depth curve in a water phantom and its performance has been compared to that of a standard ion chamber. Besides, its absolute RL yield has been compared to that of an RL probe based on the commercial Al2O3:C phosphor.
publishDate 2010
dc.date.none.fl_str_mv 2010-01
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/96033
Molina, Pablo Fernando; Prokic, M.; Marcazzo, Salvador Julian; Santiago, Martin Alejo; Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb; Pergamon-Elsevier Science Ltd; Radiation Measurements; 45; 1; 1-2010; 78-82
1350-4487
CONICET Digital
CONICET
url http://hdl.handle.net/11336/96033
identifier_str_mv Molina, Pablo Fernando; Prokic, M.; Marcazzo, Salvador Julian; Santiago, Martin Alejo; Characterization of a fiberoptic radiotherapy dosimetry probe based on Mg2SiO4:Tb; Pergamon-Elsevier Science Ltd; Radiation Measurements; 45; 1; 1-2010; 78-82
1350-4487
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1016/j.radmeas.2009.11.040
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S1350448709003588
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Pergamon-Elsevier Science Ltd
publisher.none.fl_str_mv Pergamon-Elsevier Science Ltd
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844613980070346752
score 13.070432