A pulsed hard X-ray source with shot to shot reproducible spectrum, based on a 4.7 kJ small-chamber Mather-type plasma focus device, is presented. The hard X-ray output spectrum was measured in a single shot basis by differential absorption on metallic plates. The measured spectra have a single dominant peak around 75 keV and a spectral bandwidth covering the 40-150 keV range. A hard X-ray dose of (53±3) μGy per shot was measured on axis at 53 cm from the source, and found to be uniform within a half aperture angle of 6°. © 2010 Elsevier B.V.
Fil: Raspa, Veronica Diana. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
Fil: Knoblauch, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
Fil: Di Lorenzo, Francisco Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
Fil: Moreno, Cesar Hugo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
Materia
Flash Hard X-Ray Source
Flash Radiography
Plasma Focus Hard X-Rays
Single Shot Hxr Spectral Analysis
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/61472

id CONICETDig_69cf139a031f218a392af569833d6647
oai_identifier_str oai:ri.conicet.gov.ar:11336/61472
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrumRaspa, Veronica DianaKnoblauch, PabloDi Lorenzo, Francisco JavierMoreno, Cesar HugoFlash Hard X-Ray SourceFlash RadiographyPlasma Focus Hard X-RaysSingle Shot Hxr Spectral Analysishttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1A pulsed hard X-ray source with shot to shot reproducible spectrum, based on a 4.7 kJ small-chamber Mather-type plasma focus device, is presented. The hard X-ray output spectrum was measured in a single shot basis by differential absorption on metallic plates. The measured spectra have a single dominant peak around 75 keV and a spectral bandwidth covering the 40-150 keV range. A hard X-ray dose of (53±3) μGy per shot was measured on axis at 53 cm from the source, and found to be uniform within a half aperture angle of 6°. © 2010 Elsevier B.V.Fil: Raspa, Veronica Diana. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; ArgentinaFil: Knoblauch, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; ArgentinaFil: Di Lorenzo, Francisco Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; ArgentinaFil: Moreno, Cesar Hugo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; ArgentinaElsevier Science2010-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/61472Raspa, Veronica Diana; Knoblauch, Pablo; Di Lorenzo, Francisco Javier; Moreno, Cesar Hugo; Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum; Elsevier Science; Physics Letters A; 374; 46; 10-2010; 4675-46770375-9601CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0375960110012041info:eu-repo/semantics/altIdentifier/doi/10.1016/j.physleta.2010.09.023info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:35:45Zoai:ri.conicet.gov.ar:11336/61472instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:35:45.923CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
title Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
spellingShingle Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
Raspa, Veronica Diana
Flash Hard X-Ray Source
Flash Radiography
Plasma Focus Hard X-Rays
Single Shot Hxr Spectral Analysis
title_short Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
title_full Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
title_fullStr Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
title_full_unstemmed Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
title_sort Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum
dc.creator.none.fl_str_mv Raspa, Veronica Diana
Knoblauch, Pablo
Di Lorenzo, Francisco Javier
Moreno, Cesar Hugo
author Raspa, Veronica Diana
author_facet Raspa, Veronica Diana
Knoblauch, Pablo
Di Lorenzo, Francisco Javier
Moreno, Cesar Hugo
author_role author
author2 Knoblauch, Pablo
Di Lorenzo, Francisco Javier
Moreno, Cesar Hugo
author2_role author
author
author
dc.subject.none.fl_str_mv Flash Hard X-Ray Source
Flash Radiography
Plasma Focus Hard X-Rays
Single Shot Hxr Spectral Analysis
topic Flash Hard X-Ray Source
Flash Radiography
Plasma Focus Hard X-Rays
Single Shot Hxr Spectral Analysis
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv A pulsed hard X-ray source with shot to shot reproducible spectrum, based on a 4.7 kJ small-chamber Mather-type plasma focus device, is presented. The hard X-ray output spectrum was measured in a single shot basis by differential absorption on metallic plates. The measured spectra have a single dominant peak around 75 keV and a spectral bandwidth covering the 40-150 keV range. A hard X-ray dose of (53±3) μGy per shot was measured on axis at 53 cm from the source, and found to be uniform within a half aperture angle of 6°. © 2010 Elsevier B.V.
Fil: Raspa, Veronica Diana. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
Fil: Knoblauch, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
Fil: Di Lorenzo, Francisco Javier. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
Fil: Moreno, Cesar Hugo. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Física del Plasma. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Física del Plasma; Argentina
description A pulsed hard X-ray source with shot to shot reproducible spectrum, based on a 4.7 kJ small-chamber Mather-type plasma focus device, is presented. The hard X-ray output spectrum was measured in a single shot basis by differential absorption on metallic plates. The measured spectra have a single dominant peak around 75 keV and a spectral bandwidth covering the 40-150 keV range. A hard X-ray dose of (53±3) μGy per shot was measured on axis at 53 cm from the source, and found to be uniform within a half aperture angle of 6°. © 2010 Elsevier B.V.
publishDate 2010
dc.date.none.fl_str_mv 2010-10
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/61472
Raspa, Veronica Diana; Knoblauch, Pablo; Di Lorenzo, Francisco Javier; Moreno, Cesar Hugo; Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum; Elsevier Science; Physics Letters A; 374; 46; 10-2010; 4675-4677
0375-9601
CONICET Digital
CONICET
url http://hdl.handle.net/11336/61472
identifier_str_mv Raspa, Veronica Diana; Knoblauch, Pablo; Di Lorenzo, Francisco Javier; Moreno, Cesar Hugo; Plasma focus based flash hard X-ray source in the 100 keV region with reproducible spectrum; Elsevier Science; Physics Letters A; 374; 46; 10-2010; 4675-4677
0375-9601
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0375960110012041
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.physleta.2010.09.023
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier Science
publisher.none.fl_str_mv Elsevier Science
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844613116422258688
score 13.070432