The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd2 O2 S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed. © 2007 American Institute of Physics.
Fil:Raspa, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.
Fil:Moreno, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.
Fil:Sigaut, L. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.
Fuente
J Appl Phys 2007;102(12)
Materia
Estimation
Image intensifiers (electron tube)
Metal detectors
Optimization
Phosphors
X ray radiography
Flash radiography
Mather-type tabletop plasma
Metallic objects
Phosphor intensifiers
Plasma devices
Nivel de accesibilidad
acceso abierto
Condiciones de uso
http://creativecommons.org/licenses/by/2.5/ar
Repositorio
Biblioteca Digital (UBA-FCEN)
Institución
Universidad Nacional de Buenos Aires. Facultad de Ciencias Exactas y Naturales
OAI Identificador
paperaa:paper_00218979_v102_n12_p_Raspa

id BDUBAFCEN_f58ce65051e5247a1bf74289a8a78706
oai_identifier_str paperaa:paper_00218979_v102_n12_p_Raspa
network_acronym_str BDUBAFCEN
repository_id_str 1896
network_name_str Biblioteca Digital (UBA-FCEN)
spelling Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objectsRaspa, V.Moreno, C.Sigaut, L.Clausse, A.EstimationImage intensifiers (electron tube)Metal detectorsOptimizationPhosphorsX ray radiographyFlash radiographyMather-type tabletop plasmaMetallic objectsPhosphor intensifiersPlasma devicesThe effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd2 O2 S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed. © 2007 American Institute of Physics.Fil:Raspa, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.Fil:Moreno, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.Fil:Sigaut, L. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.2007info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfhttp://hdl.handle.net/20.500.12110/paper_00218979_v102_n12_p_RaspaJ Appl Phys 2007;102(12)reponame:Biblioteca Digital (UBA-FCEN)instname:Universidad Nacional de Buenos Aires. Facultad de Ciencias Exactas y Naturalesinstacron:UBA-FCENenginfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/2.5/ar2025-09-29T13:43:09Zpaperaa:paper_00218979_v102_n12_p_RaspaInstitucionalhttps://digital.bl.fcen.uba.ar/Universidad públicaNo correspondehttps://digital.bl.fcen.uba.ar/cgi-bin/oaiserver.cgiana@bl.fcen.uba.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:18962025-09-29 13:43:10.809Biblioteca Digital (UBA-FCEN) - Universidad Nacional de Buenos Aires. Facultad de Ciencias Exactas y Naturalesfalse
dc.title.none.fl_str_mv Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
spellingShingle Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
Raspa, V.
Estimation
Image intensifiers (electron tube)
Metal detectors
Optimization
Phosphors
X ray radiography
Flash radiography
Mather-type tabletop plasma
Metallic objects
Phosphor intensifiers
Plasma devices
title_short Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_full Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_fullStr Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_full_unstemmed Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
title_sort Effective hard x-ray spectrum of a tabletop Mather-type plasma focus optimized for flash radiography of metallic objects
dc.creator.none.fl_str_mv Raspa, V.
Moreno, C.
Sigaut, L.
Clausse, A.
author Raspa, V.
author_facet Raspa, V.
Moreno, C.
Sigaut, L.
Clausse, A.
author_role author
author2 Moreno, C.
Sigaut, L.
Clausse, A.
author2_role author
author
author
dc.subject.none.fl_str_mv Estimation
Image intensifiers (electron tube)
Metal detectors
Optimization
Phosphors
X ray radiography
Flash radiography
Mather-type tabletop plasma
Metallic objects
Phosphor intensifiers
Plasma devices
topic Estimation
Image intensifiers (electron tube)
Metal detectors
Optimization
Phosphors
X ray radiography
Flash radiography
Mather-type tabletop plasma
Metallic objects
Phosphor intensifiers
Plasma devices
dc.description.none.fl_txt_mv The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd2 O2 S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed. © 2007 American Institute of Physics.
Fil:Raspa, V. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.
Fil:Moreno, C. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.
Fil:Sigaut, L. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales; Argentina.
description The effective spectrum of the hard x-ray output of a Mather-type tabletop plasma focus device was determined from attenuation data on metallic samples using commercial radiographic film coupled to a Gd2 O2 S:Tb phosphor intensifier screen. It was found that the radiation has relevant spectral components in the 40-150 keV range, with a single maximum around 60-80 keV. The radiation output allows for 50 ns resolution, good contrast, and introspective imaging of metallic objects even through metallic walls. A numerical estimation of the induced voltage on the focus during the compressional stage is briefly discussed. © 2007 American Institute of Physics.
publishDate 2007
dc.date.none.fl_str_mv 2007
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/20.500.12110/paper_00218979_v102_n12_p_Raspa
url http://hdl.handle.net/20.500.12110/paper_00218979_v102_n12_p_Raspa
dc.language.none.fl_str_mv eng
language eng
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
http://creativecommons.org/licenses/by/2.5/ar
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by/2.5/ar
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv J Appl Phys 2007;102(12)
reponame:Biblioteca Digital (UBA-FCEN)
instname:Universidad Nacional de Buenos Aires. Facultad de Ciencias Exactas y Naturales
instacron:UBA-FCEN
reponame_str Biblioteca Digital (UBA-FCEN)
collection Biblioteca Digital (UBA-FCEN)
instname_str Universidad Nacional de Buenos Aires. Facultad de Ciencias Exactas y Naturales
instacron_str UBA-FCEN
institution UBA-FCEN
repository.name.fl_str_mv Biblioteca Digital (UBA-FCEN) - Universidad Nacional de Buenos Aires. Facultad de Ciencias Exactas y Naturales
repository.mail.fl_str_mv ana@bl.fcen.uba.ar
_version_ 1844618740820344832
score 13.070432