Exploring tear viscosity with quartz crystal microbalance technology

Autores
Muñoz, Gabriel Guillermo; Millicovsky, Martín Javier; Cerrudo, J.; Peñalva, A.; Machtey, M.; Reta, J.; Torres, R.; Campana, Diego Martin; Zalazar, Martin
Año de publicación
2024
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Tear viscosity is a critical property affecting tear distribution and ocular surface stability. While not widely established as a primary diagnostic marker, deviations from normal viscosity can impact ocular health, potentiallycontributing to conditions like dry eye syndrome. Despite its importance, traditional viscometers require sample volumes that are not feasible to use with tear volume. This research introduces a novel Quartz Crystal Microbalance(QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimalsample volumes. Human tear samples, solutions used in artificial eye drops, and various commercial eyedrop brands were evaluated. Results show that the QCM method aligns with established viscosity ranges, withhealthy human tears averaging 1.73 ± 0.61 cP, within the typical range of 1 to 10 cP. Variability in eye dropviscosities is attributed to chemical composition differences. QCM measurements of one eye drop brand closelymatch those from a commercial viscometer. The QCM method offers benefits such as reduced sampleconsumption and rapid results, enhancing understanding of tear dynamics for ocular health. Further research withlarger sample sizes is needed to establish normative viscosity values in healthy individuals and those with dry eyesyndrome, crucial for validating the device´s clinical efficacy.
Fil: Muñoz, Gabriel Guillermo. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Millicovsky, Martín Javier. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina
Fil: Cerrudo, J.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Peñalva, A.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Machtey, M.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Reta, J.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Torres, R.. R.O.M.A.T Creator Center; Argentina
Fil: Campana, Diego Martin. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Zalazar, Martin. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Materia
QCM
Quartz Crystal Microbalance
Tear viscosity
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/254059

id CONICETDig_68ebd2804558cda1f2fdc8a15d4d764b
oai_identifier_str oai:ri.conicet.gov.ar:11336/254059
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Exploring tear viscosity with quartz crystal microbalance technologyMuñoz, Gabriel GuillermoMillicovsky, Martín JavierCerrudo, J.Peñalva, A.Machtey, M.Reta, J.Torres, R.Campana, Diego MartinZalazar, MartinQCMQuartz Crystal MicrobalanceTear viscosityhttps://purl.org/becyt/ford/2.6https://purl.org/becyt/ford/2Tear viscosity is a critical property affecting tear distribution and ocular surface stability. While not widely established as a primary diagnostic marker, deviations from normal viscosity can impact ocular health, potentiallycontributing to conditions like dry eye syndrome. Despite its importance, traditional viscometers require sample volumes that are not feasible to use with tear volume. This research introduces a novel Quartz Crystal Microbalance(QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimalsample volumes. Human tear samples, solutions used in artificial eye drops, and various commercial eyedrop brands were evaluated. Results show that the QCM method aligns with established viscosity ranges, withhealthy human tears averaging 1.73 ± 0.61 cP, within the typical range of 1 to 10 cP. Variability in eye dropviscosities is attributed to chemical composition differences. QCM measurements of one eye drop brand closelymatch those from a commercial viscometer. The QCM method offers benefits such as reduced sampleconsumption and rapid results, enhancing understanding of tear dynamics for ocular health. Further research withlarger sample sizes is needed to establish normative viscosity values in healthy individuals and those with dry eyesyndrome, crucial for validating the device´s clinical efficacy.Fil: Muñoz, Gabriel Guillermo. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaFil: Millicovsky, Martín Javier. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; ArgentinaFil: Cerrudo, J.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaFil: Peñalva, A.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaFil: Machtey, M.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaFil: Reta, J.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaFil: Torres, R.. R.O.M.A.T Creator Center; ArgentinaFil: Campana, Diego Martin. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaFil: Zalazar, Martin. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaAmerican Institute of Physics2024-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/254059Muñoz, Gabriel Guillermo; Millicovsky, Martín Javier; Cerrudo, J.; Peñalva, A.; Machtey, M.; et al.; Exploring tear viscosity with quartz crystal microbalance technology; American Institute of Physics; Review of Scientific Instruments; 95; 7; 7-2024; 1-100034-6748CONICET DigitalCONICETenghttps://ri.conicet.gov.ar/handle/11336/254057info:eu-repo/semantics/altIdentifier/url/https://pubs.aip.org/rsi/article/95/7/075107/3303654/Exploring-tear-viscosity-with-quartz-crystalinfo:eu-repo/semantics/altIdentifier/doi/10.1063/5.0207182info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:32:53Zoai:ri.conicet.gov.ar:11336/254059instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:32:53.972CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Exploring tear viscosity with quartz crystal microbalance technology
title Exploring tear viscosity with quartz crystal microbalance technology
spellingShingle Exploring tear viscosity with quartz crystal microbalance technology
Muñoz, Gabriel Guillermo
QCM
Quartz Crystal Microbalance
Tear viscosity
title_short Exploring tear viscosity with quartz crystal microbalance technology
title_full Exploring tear viscosity with quartz crystal microbalance technology
title_fullStr Exploring tear viscosity with quartz crystal microbalance technology
title_full_unstemmed Exploring tear viscosity with quartz crystal microbalance technology
title_sort Exploring tear viscosity with quartz crystal microbalance technology
dc.creator.none.fl_str_mv Muñoz, Gabriel Guillermo
Millicovsky, Martín Javier
Cerrudo, J.
Peñalva, A.
Machtey, M.
Reta, J.
Torres, R.
Campana, Diego Martin
Zalazar, Martin
author Muñoz, Gabriel Guillermo
author_facet Muñoz, Gabriel Guillermo
Millicovsky, Martín Javier
Cerrudo, J.
Peñalva, A.
Machtey, M.
Reta, J.
Torres, R.
Campana, Diego Martin
Zalazar, Martin
author_role author
author2 Millicovsky, Martín Javier
Cerrudo, J.
Peñalva, A.
Machtey, M.
Reta, J.
Torres, R.
Campana, Diego Martin
Zalazar, Martin
author2_role author
author
author
author
author
author
author
author
dc.subject.none.fl_str_mv QCM
Quartz Crystal Microbalance
Tear viscosity
topic QCM
Quartz Crystal Microbalance
Tear viscosity
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.6
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv Tear viscosity is a critical property affecting tear distribution and ocular surface stability. While not widely established as a primary diagnostic marker, deviations from normal viscosity can impact ocular health, potentiallycontributing to conditions like dry eye syndrome. Despite its importance, traditional viscometers require sample volumes that are not feasible to use with tear volume. This research introduces a novel Quartz Crystal Microbalance(QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimalsample volumes. Human tear samples, solutions used in artificial eye drops, and various commercial eyedrop brands were evaluated. Results show that the QCM method aligns with established viscosity ranges, withhealthy human tears averaging 1.73 ± 0.61 cP, within the typical range of 1 to 10 cP. Variability in eye dropviscosities is attributed to chemical composition differences. QCM measurements of one eye drop brand closelymatch those from a commercial viscometer. The QCM method offers benefits such as reduced sampleconsumption and rapid results, enhancing understanding of tear dynamics for ocular health. Further research withlarger sample sizes is needed to establish normative viscosity values in healthy individuals and those with dry eyesyndrome, crucial for validating the device´s clinical efficacy.
Fil: Muñoz, Gabriel Guillermo. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Millicovsky, Martín Javier. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina
Fil: Cerrudo, J.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Peñalva, A.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Machtey, M.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Reta, J.. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Torres, R.. R.O.M.A.T Creator Center; Argentina
Fil: Campana, Diego Martin. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Zalazar, Martin. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
description Tear viscosity is a critical property affecting tear distribution and ocular surface stability. While not widely established as a primary diagnostic marker, deviations from normal viscosity can impact ocular health, potentiallycontributing to conditions like dry eye syndrome. Despite its importance, traditional viscometers require sample volumes that are not feasible to use with tear volume. This research introduces a novel Quartz Crystal Microbalance(QCM)-based method for tear viscosity measurement, offering a viscometer prototype that operates with minimalsample volumes. Human tear samples, solutions used in artificial eye drops, and various commercial eyedrop brands were evaluated. Results show that the QCM method aligns with established viscosity ranges, withhealthy human tears averaging 1.73 ± 0.61 cP, within the typical range of 1 to 10 cP. Variability in eye dropviscosities is attributed to chemical composition differences. QCM measurements of one eye drop brand closelymatch those from a commercial viscometer. The QCM method offers benefits such as reduced sampleconsumption and rapid results, enhancing understanding of tear dynamics for ocular health. Further research withlarger sample sizes is needed to establish normative viscosity values in healthy individuals and those with dry eyesyndrome, crucial for validating the device´s clinical efficacy.
publishDate 2024
dc.date.none.fl_str_mv 2024-07
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/254059
Muñoz, Gabriel Guillermo; Millicovsky, Martín Javier; Cerrudo, J.; Peñalva, A.; Machtey, M.; et al.; Exploring tear viscosity with quartz crystal microbalance technology; American Institute of Physics; Review of Scientific Instruments; 95; 7; 7-2024; 1-10
0034-6748
CONICET Digital
CONICET
url http://hdl.handle.net/11336/254059
identifier_str_mv Muñoz, Gabriel Guillermo; Millicovsky, Martín Javier; Cerrudo, J.; Peñalva, A.; Machtey, M.; et al.; Exploring tear viscosity with quartz crystal microbalance technology; American Institute of Physics; Review of Scientific Instruments; 95; 7; 7-2024; 1-10
0034-6748
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ri.conicet.gov.ar/handle/11336/254057
info:eu-repo/semantics/altIdentifier/url/https://pubs.aip.org/rsi/article/95/7/075107/3303654/Exploring-tear-viscosity-with-quartz-crystal
info:eu-repo/semantics/altIdentifier/doi/10.1063/5.0207182
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv American Institute of Physics
publisher.none.fl_str_mv American Institute of Physics
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844613006575534080
score 13.070432