Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography

Autores
González, Martín Germán; Acosta, Eduardo Omar; Santiago, Guillermo
Año de publicación
2018
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
In this paper we present a method to determine the spatial resolution and sensitivity of systems for optoacoustic tomography (OAT). The method consists of obtaining the image of a sample based on a transparent film embedded in agarose. The film has a certain pattern made with a laser printer that allows to obtain the system spatial resolution. Moreover, since the damage threshold of the ink pattern is similar to that of living tissue, it is also possible to determine if the system is sensitive enough to be applied on biological samples. The method is straightforward, fast and repeatable, and was tested in a OAT system for obtaining two-dimensional images developed in our laboratory.
En este trabajo se presenta un método para determinar la resolución espacial y la sensibilidad de sistemas para tomografía optoacústica (TOA). Éste consiste en la obtención de la imagen de una muestra basada en una lámina transparente embebida en agarosa. La lámina posee un determinado patrón realizado con una impresora láser que permite determinar la resolución espacial del sistema. Por otro lado, como su umbral de daño es similar a del tejido vivo, también es posible establecer si el sistema posee la suficiente sensibilidad para ser usado en muestras biológicas. El método es directo, rápido y repetible, y fue probado en un sistema TOA para obtención de imágenes bidimensionales desarrollado en nuestro laboratorio.
Fil: González, Martín Germán. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad de Buenos Aires. Facultad de Ingeniería; Argentina
Fil: Acosta, Eduardo Omar. Universidad de Buenos Aires. Facultad de Ingeniería; Argentina
Fil: Santiago, Guillermo. Universidad de Buenos Aires. Facultad de Ingeniería; Argentina
Materia
OPTOACOUSTIC TOMOGRAPHY
SPATIAL RESOLUTION
TWO-DIMENSIONAL IMAGES
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/178236

id CONICETDig_5a3cf11b3e4b0cc3baa0d959bed5a059
oai_identifier_str oai:ri.conicet.gov.ar:11336/178236
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Simple method to determine the resolution and sensitivity of systems for optoacoustic tomographyMétodo sencillo para determinar la resolución y sensibilidad de sistemas para tomografía optoacústicaGonzález, Martín GermánAcosta, Eduardo OmarSantiago, GuillermoOPTOACOUSTIC TOMOGRAPHYSPATIAL RESOLUTIONTWO-DIMENSIONAL IMAGEShttps://purl.org/becyt/ford/2.2https://purl.org/becyt/ford/2In this paper we present a method to determine the spatial resolution and sensitivity of systems for optoacoustic tomography (OAT). The method consists of obtaining the image of a sample based on a transparent film embedded in agarose. The film has a certain pattern made with a laser printer that allows to obtain the system spatial resolution. Moreover, since the damage threshold of the ink pattern is similar to that of living tissue, it is also possible to determine if the system is sensitive enough to be applied on biological samples. The method is straightforward, fast and repeatable, and was tested in a OAT system for obtaining two-dimensional images developed in our laboratory.En este trabajo se presenta un método para determinar la resolución espacial y la sensibilidad de sistemas para tomografía optoacústica (TOA). Éste consiste en la obtención de la imagen de una muestra basada en una lámina transparente embebida en agarosa. La lámina posee un determinado patrón realizado con una impresora láser que permite determinar la resolución espacial del sistema. Por otro lado, como su umbral de daño es similar a del tejido vivo, también es posible establecer si el sistema posee la suficiente sensibilidad para ser usado en muestras biológicas. El método es directo, rápido y repetible, y fue probado en un sistema TOA para obtención de imágenes bidimensionales desarrollado en nuestro laboratorio.Fil: González, Martín Germán. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad de Buenos Aires. Facultad de Ingeniería; ArgentinaFil: Acosta, Eduardo Omar. Universidad de Buenos Aires. Facultad de Ingeniería; ArgentinaFil: Santiago, Guillermo. Universidad de Buenos Aires. Facultad de Ingeniería; ArgentinaUniversidad de Buenos Aires. Facultad de Ingeniería2018-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/178236González, Martín Germán; Acosta, Eduardo Omar; Santiago, Guillermo; Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography; Universidad de Buenos Aires. Facultad de Ingeniería; Elektron; 2; 2; 12-2018; 63-662525-0159CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://elektron.fi.uba.ar/index.php/elektron/article/view/47info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:55:58Zoai:ri.conicet.gov.ar:11336/178236instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:55:58.849CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
Método sencillo para determinar la resolución y sensibilidad de sistemas para tomografía optoacústica
title Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
spellingShingle Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
González, Martín Germán
OPTOACOUSTIC TOMOGRAPHY
SPATIAL RESOLUTION
TWO-DIMENSIONAL IMAGES
title_short Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
title_full Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
title_fullStr Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
title_full_unstemmed Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
title_sort Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography
dc.creator.none.fl_str_mv González, Martín Germán
Acosta, Eduardo Omar
Santiago, Guillermo
author González, Martín Germán
author_facet González, Martín Germán
Acosta, Eduardo Omar
Santiago, Guillermo
author_role author
author2 Acosta, Eduardo Omar
Santiago, Guillermo
author2_role author
author
dc.subject.none.fl_str_mv OPTOACOUSTIC TOMOGRAPHY
SPATIAL RESOLUTION
TWO-DIMENSIONAL IMAGES
topic OPTOACOUSTIC TOMOGRAPHY
SPATIAL RESOLUTION
TWO-DIMENSIONAL IMAGES
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.2
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv In this paper we present a method to determine the spatial resolution and sensitivity of systems for optoacoustic tomography (OAT). The method consists of obtaining the image of a sample based on a transparent film embedded in agarose. The film has a certain pattern made with a laser printer that allows to obtain the system spatial resolution. Moreover, since the damage threshold of the ink pattern is similar to that of living tissue, it is also possible to determine if the system is sensitive enough to be applied on biological samples. The method is straightforward, fast and repeatable, and was tested in a OAT system for obtaining two-dimensional images developed in our laboratory.
En este trabajo se presenta un método para determinar la resolución espacial y la sensibilidad de sistemas para tomografía optoacústica (TOA). Éste consiste en la obtención de la imagen de una muestra basada en una lámina transparente embebida en agarosa. La lámina posee un determinado patrón realizado con una impresora láser que permite determinar la resolución espacial del sistema. Por otro lado, como su umbral de daño es similar a del tejido vivo, también es posible establecer si el sistema posee la suficiente sensibilidad para ser usado en muestras biológicas. El método es directo, rápido y repetible, y fue probado en un sistema TOA para obtención de imágenes bidimensionales desarrollado en nuestro laboratorio.
Fil: González, Martín Germán. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad de Buenos Aires. Facultad de Ingeniería; Argentina
Fil: Acosta, Eduardo Omar. Universidad de Buenos Aires. Facultad de Ingeniería; Argentina
Fil: Santiago, Guillermo. Universidad de Buenos Aires. Facultad de Ingeniería; Argentina
description In this paper we present a method to determine the spatial resolution and sensitivity of systems for optoacoustic tomography (OAT). The method consists of obtaining the image of a sample based on a transparent film embedded in agarose. The film has a certain pattern made with a laser printer that allows to obtain the system spatial resolution. Moreover, since the damage threshold of the ink pattern is similar to that of living tissue, it is also possible to determine if the system is sensitive enough to be applied on biological samples. The method is straightforward, fast and repeatable, and was tested in a OAT system for obtaining two-dimensional images developed in our laboratory.
publishDate 2018
dc.date.none.fl_str_mv 2018-12
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/178236
González, Martín Germán; Acosta, Eduardo Omar; Santiago, Guillermo; Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography; Universidad de Buenos Aires. Facultad de Ingeniería; Elektron; 2; 2; 12-2018; 63-66
2525-0159
CONICET Digital
CONICET
url http://hdl.handle.net/11336/178236
identifier_str_mv González, Martín Germán; Acosta, Eduardo Omar; Santiago, Guillermo; Simple method to determine the resolution and sensitivity of systems for optoacoustic tomography; Universidad de Buenos Aires. Facultad de Ingeniería; Elektron; 2; 2; 12-2018; 63-66
2525-0159
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://elektron.fi.uba.ar/index.php/elektron/article/view/47
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Universidad de Buenos Aires. Facultad de Ingeniería
publisher.none.fl_str_mv Universidad de Buenos Aires. Facultad de Ingeniería
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842269374879105024
score 13.13397