Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin
- Autores
- Cian, Raúl Esteban; Drago, Silvina Rosa; De Greef, Dardo M.; Torres, Roberto L.; González, Rolando J.
- Año de publicación
- 2010
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Four hydrolysates were obtained from bovine hemoglobin concentrate (BHC) and used to fortify extruded maize products. Extrusion was carried out with a Brabender single-screw extruder. Physicochemical properties from extruded products were measured. The iron availability was estimated by the dializability method, which measures the mineral dialyzed after a double digestion simulating physiological processes. The physicochemical properties of the extruded products were not affected by fortification, with the exception of total soluble solids. The enzymic hydrolysis increased the iron dializability with respect to the substrate. The highest value of iron dializability corresponded to the more hydrolysated sample. Extruded products fortified with BHC hydrolysates showed higher iron dializability than those fortified with BHC. However, iron dializability corresponding to BHC is lower than that expected from heme iron. Therefore, heme-iron availability is low when it is determined in the absence of meat proteins, and hydrolysis could increase potential iron availability.
Fil: Cian, Raúl Esteban. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina
Fil: Drago, Silvina Rosa. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
Fil: De Greef, Dardo M.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina
Fil: Torres, Roberto L.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina
Fil: González, Rolando J.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina - Materia
-
AVAILABILITY
EXTRUSION
FORTIFICATION
HEMOGLOBIN
HYDROLYSIS - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/97458
Ver los metadatos del registro completo
id |
CONICETDig_51c9c2acc8caac5a27b3db9921016750 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/97458 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobinCian, Raúl EstebanDrago, Silvina RosaDe Greef, Dardo M.Torres, Roberto L.González, Rolando J.AVAILABILITYEXTRUSIONFORTIFICATIONHEMOGLOBINHYDROLYSIShttps://purl.org/becyt/ford/2.11https://purl.org/becyt/ford/2Four hydrolysates were obtained from bovine hemoglobin concentrate (BHC) and used to fortify extruded maize products. Extrusion was carried out with a Brabender single-screw extruder. Physicochemical properties from extruded products were measured. The iron availability was estimated by the dializability method, which measures the mineral dialyzed after a double digestion simulating physiological processes. The physicochemical properties of the extruded products were not affected by fortification, with the exception of total soluble solids. The enzymic hydrolysis increased the iron dializability with respect to the substrate. The highest value of iron dializability corresponded to the more hydrolysated sample. Extruded products fortified with BHC hydrolysates showed higher iron dializability than those fortified with BHC. However, iron dializability corresponding to BHC is lower than that expected from heme iron. Therefore, heme-iron availability is low when it is determined in the absence of meat proteins, and hydrolysis could increase potential iron availability.Fil: Cian, Raúl Esteban. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; ArgentinaFil: Drago, Silvina Rosa. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; ArgentinaFil: De Greef, Dardo M.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; ArgentinaFil: Torres, Roberto L.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; ArgentinaFil: González, Rolando J.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; ArgentinaInforma Healthcare2010-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/97458Cian, Raúl Esteban; Drago, Silvina Rosa; De Greef, Dardo M.; Torres, Roberto L.; González, Rolando J.; Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin; Informa Healthcare; International Journal of Food Sciences and Nutrition; 61; 6; 9-2010; 573-5820963-7486CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.tandfonline.com/doi/abs/10.3109/09637481003649075info:eu-repo/semantics/altIdentifier/doi/10.3109/09637481003649075info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-17T10:40:58Zoai:ri.conicet.gov.ar:11336/97458instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-17 10:40:58.346CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin |
title |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin |
spellingShingle |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin Cian, Raúl Esteban AVAILABILITY EXTRUSION FORTIFICATION HEMOGLOBIN HYDROLYSIS |
title_short |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin |
title_full |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin |
title_fullStr |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin |
title_full_unstemmed |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin |
title_sort |
Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin |
dc.creator.none.fl_str_mv |
Cian, Raúl Esteban Drago, Silvina Rosa De Greef, Dardo M. Torres, Roberto L. González, Rolando J. |
author |
Cian, Raúl Esteban |
author_facet |
Cian, Raúl Esteban Drago, Silvina Rosa De Greef, Dardo M. Torres, Roberto L. González, Rolando J. |
author_role |
author |
author2 |
Drago, Silvina Rosa De Greef, Dardo M. Torres, Roberto L. González, Rolando J. |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
AVAILABILITY EXTRUSION FORTIFICATION HEMOGLOBIN HYDROLYSIS |
topic |
AVAILABILITY EXTRUSION FORTIFICATION HEMOGLOBIN HYDROLYSIS |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.11 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
Four hydrolysates were obtained from bovine hemoglobin concentrate (BHC) and used to fortify extruded maize products. Extrusion was carried out with a Brabender single-screw extruder. Physicochemical properties from extruded products were measured. The iron availability was estimated by the dializability method, which measures the mineral dialyzed after a double digestion simulating physiological processes. The physicochemical properties of the extruded products were not affected by fortification, with the exception of total soluble solids. The enzymic hydrolysis increased the iron dializability with respect to the substrate. The highest value of iron dializability corresponded to the more hydrolysated sample. Extruded products fortified with BHC hydrolysates showed higher iron dializability than those fortified with BHC. However, iron dializability corresponding to BHC is lower than that expected from heme iron. Therefore, heme-iron availability is low when it is determined in the absence of meat proteins, and hydrolysis could increase potential iron availability. Fil: Cian, Raúl Esteban. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina Fil: Drago, Silvina Rosa. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina Fil: De Greef, Dardo M.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina Fil: Torres, Roberto L.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina Fil: González, Rolando J.. Universidad Nacional del Litoral. Facultad de Ingeniería Química. Instituto de Tecnología de los Alimentos; Argentina |
description |
Four hydrolysates were obtained from bovine hemoglobin concentrate (BHC) and used to fortify extruded maize products. Extrusion was carried out with a Brabender single-screw extruder. Physicochemical properties from extruded products were measured. The iron availability was estimated by the dializability method, which measures the mineral dialyzed after a double digestion simulating physiological processes. The physicochemical properties of the extruded products were not affected by fortification, with the exception of total soluble solids. The enzymic hydrolysis increased the iron dializability with respect to the substrate. The highest value of iron dializability corresponded to the more hydrolysated sample. Extruded products fortified with BHC hydrolysates showed higher iron dializability than those fortified with BHC. However, iron dializability corresponding to BHC is lower than that expected from heme iron. Therefore, heme-iron availability is low when it is determined in the absence of meat proteins, and hydrolysis could increase potential iron availability. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-09 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/97458 Cian, Raúl Esteban; Drago, Silvina Rosa; De Greef, Dardo M.; Torres, Roberto L.; González, Rolando J.; Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin; Informa Healthcare; International Journal of Food Sciences and Nutrition; 61; 6; 9-2010; 573-582 0963-7486 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/97458 |
identifier_str_mv |
Cian, Raúl Esteban; Drago, Silvina Rosa; De Greef, Dardo M.; Torres, Roberto L.; González, Rolando J.; Iron and zinc availability and some physical characteristics from extruded products with added concentrate and hydrolysates from bovine hemoglobin; Informa Healthcare; International Journal of Food Sciences and Nutrition; 61; 6; 9-2010; 573-582 0963-7486 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.tandfonline.com/doi/abs/10.3109/09637481003649075 info:eu-repo/semantics/altIdentifier/doi/10.3109/09637481003649075 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Informa Healthcare |
publisher.none.fl_str_mv |
Informa Healthcare |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1843605845539028992 |
score |
13.001348 |