Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation

Autores
Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; Messina, Germán Alejandro
Año de publicación
2019
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication.
Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Pereira, Sirley Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Fernández Baldo, Martín Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Materia
POLY-VINYL ALCOHOL
POLY-VINYLPYRROLIDONE
ELECTROCHEMICAL IMMUNOSENSORS
TOXOPLASMOSIS
NANOCOMPOSITE
GRAPHENE OXIDE
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/111020

id CONICETDig_42a8e20c3e26d1f76ac07fd0a1a10870
oai_identifier_str oai:ri.conicet.gov.ar:11336/111020
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitationTakara, Eduardo AndresPereira, Sirley VanesaScala Benuzzi, María LuzFernández Baldo, Martín AlejandroRaba, JulioMessina, Germán AlejandroPOLY-VINYL ALCOHOLPOLY-VINYLPYRROLIDONEELECTROCHEMICAL IMMUNOSENSORSTOXOPLASMOSISNANOCOMPOSITEGRAPHENE OXIDEhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication.Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Pereira, Sirley Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Fernández Baldo, Martín Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaElsevier Science2019info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/111020Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; et al.; Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation; Elsevier Science; Talanta; 195; 2019; 699-7050039-9140CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/ww.sciencedirect.com/science/article/abs/pii/S0039914018312220info:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2018.11.070info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:22:20Zoai:ri.conicet.gov.ar:11336/111020instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:22:20.566CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
title Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
spellingShingle Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
Takara, Eduardo Andres
POLY-VINYL ALCOHOL
POLY-VINYLPYRROLIDONE
ELECTROCHEMICAL IMMUNOSENSORS
TOXOPLASMOSIS
NANOCOMPOSITE
GRAPHENE OXIDE
title_short Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
title_full Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
title_fullStr Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
title_full_unstemmed Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
title_sort Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
dc.creator.none.fl_str_mv Takara, Eduardo Andres
Pereira, Sirley Vanesa
Scala Benuzzi, María Luz
Fernández Baldo, Martín Alejandro
Raba, Julio
Messina, Germán Alejandro
author Takara, Eduardo Andres
author_facet Takara, Eduardo Andres
Pereira, Sirley Vanesa
Scala Benuzzi, María Luz
Fernández Baldo, Martín Alejandro
Raba, Julio
Messina, Germán Alejandro
author_role author
author2 Pereira, Sirley Vanesa
Scala Benuzzi, María Luz
Fernández Baldo, Martín Alejandro
Raba, Julio
Messina, Germán Alejandro
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv POLY-VINYL ALCOHOL
POLY-VINYLPYRROLIDONE
ELECTROCHEMICAL IMMUNOSENSORS
TOXOPLASMOSIS
NANOCOMPOSITE
GRAPHENE OXIDE
topic POLY-VINYL ALCOHOL
POLY-VINYLPYRROLIDONE
ELECTROCHEMICAL IMMUNOSENSORS
TOXOPLASMOSIS
NANOCOMPOSITE
GRAPHENE OXIDE
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication.
Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Pereira, Sirley Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Fernández Baldo, Martín Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
description This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication.
publishDate 2019
dc.date.none.fl_str_mv 2019
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/111020
Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; et al.; Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation; Elsevier Science; Talanta; 195; 2019; 699-705
0039-9140
CONICET Digital
CONICET
url http://hdl.handle.net/11336/111020
identifier_str_mv Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; et al.; Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation; Elsevier Science; Talanta; 195; 2019; 699-705
0039-9140
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/ww.sciencedirect.com/science/article/abs/pii/S0039914018312220
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2018.11.070
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
application/pdf
application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier Science
publisher.none.fl_str_mv Elsevier Science
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614214386188288
score 13.070432