Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation
- Autores
- Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; Messina, Germán Alejandro
- Año de publicación
- 2019
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication.
Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Pereira, Sirley Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Fernández Baldo, Martín Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina - Materia
-
POLY-VINYL ALCOHOL
POLY-VINYLPYRROLIDONE
ELECTROCHEMICAL IMMUNOSENSORS
TOXOPLASMOSIS
NANOCOMPOSITE
GRAPHENE OXIDE - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/111020
Ver los metadatos del registro completo
id |
CONICETDig_42a8e20c3e26d1f76ac07fd0a1a10870 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/111020 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitationTakara, Eduardo AndresPereira, Sirley VanesaScala Benuzzi, María LuzFernández Baldo, Martín AlejandroRaba, JulioMessina, Germán AlejandroPOLY-VINYL ALCOHOLPOLY-VINYLPYRROLIDONEELECTROCHEMICAL IMMUNOSENSORSTOXOPLASMOSISNANOCOMPOSITEGRAPHENE OXIDEhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication.Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Pereira, Sirley Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Fernández Baldo, Martín Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaElsevier Science2019info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/111020Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; et al.; Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation; Elsevier Science; Talanta; 195; 2019; 699-7050039-9140CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/ww.sciencedirect.com/science/article/abs/pii/S0039914018312220info:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2018.11.070info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:22:20Zoai:ri.conicet.gov.ar:11336/111020instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:22:20.566CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation |
title |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation |
spellingShingle |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation Takara, Eduardo Andres POLY-VINYL ALCOHOL POLY-VINYLPYRROLIDONE ELECTROCHEMICAL IMMUNOSENSORS TOXOPLASMOSIS NANOCOMPOSITE GRAPHENE OXIDE |
title_short |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation |
title_full |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation |
title_fullStr |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation |
title_full_unstemmed |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation |
title_sort |
Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation |
dc.creator.none.fl_str_mv |
Takara, Eduardo Andres Pereira, Sirley Vanesa Scala Benuzzi, María Luz Fernández Baldo, Martín Alejandro Raba, Julio Messina, Germán Alejandro |
author |
Takara, Eduardo Andres |
author_facet |
Takara, Eduardo Andres Pereira, Sirley Vanesa Scala Benuzzi, María Luz Fernández Baldo, Martín Alejandro Raba, Julio Messina, Germán Alejandro |
author_role |
author |
author2 |
Pereira, Sirley Vanesa Scala Benuzzi, María Luz Fernández Baldo, Martín Alejandro Raba, Julio Messina, Germán Alejandro |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
POLY-VINYL ALCOHOL POLY-VINYLPYRROLIDONE ELECTROCHEMICAL IMMUNOSENSORS TOXOPLASMOSIS NANOCOMPOSITE GRAPHENE OXIDE |
topic |
POLY-VINYL ALCOHOL POLY-VINYLPYRROLIDONE ELECTROCHEMICAL IMMUNOSENSORS TOXOPLASMOSIS NANOCOMPOSITE GRAPHENE OXIDE |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication. Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Pereira, Sirley Vanesa. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Fernández Baldo, Martín Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina |
description |
This article describes the development of a new electrochemical platform composed by a polymer mixture and graphene oxide (GO). The working electrode of a screen-printed carbon electrode (SPCE) was modified with nanocomposite constituted by poly-vinyl alcohol (PVA), poly-vinylpyrrolidone (PVP) and GO, which was electrochemically reduced to obtain PVA/PVP/RGO/SPCE. The interactions and morphology of the PVA/PVP/GO nanocomposite were investigated by SEM, FTIR and UV-Vis. SEM images indicated an excellent dispersion of the GO sheets in the polymer matrix. Besides, FTIR and visible UV studies revealed strong interactions between polymer mixture and GO sheets. According to electrochemical studies, the new platform increased the electroactive surface area by a factor of 20.46 compared to the unmodified SPCE. Also, the PVA/PVP/RGO/SPCE had a fast electron kinetics transfer process with a value of ks = 9.6 s-1.The modified electrode was applied to the determination of IgG anti-T. gondii antibodies for the serological diagnosis of toxoplasmosis. The IgG anti-T. gondii antibodies quantification showed a detection limit of 0.012 U mL-1, and the coefficients of variation intra-day and inter-day assays were lower than 4.5% and 6.2%, respectively. The electrochemical platform proved to be a sensitive and easily applicable tool applied to the serological diagnosis of toxoplasmosis. Therefore, the developed nanocomposite represents an excellent alternative for the electrochemical biosensor fabrication. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/111020 Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; et al.; Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation; Elsevier Science; Talanta; 195; 2019; 699-705 0039-9140 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/111020 |
identifier_str_mv |
Takara, Eduardo Andres; Pereira, Sirley Vanesa; Scala Benuzzi, María Luz; Fernández Baldo, Martín Alejandro; Raba, Julio; et al.; Novel electrochemical sensing platform based on a nanocomposite of PVA / PVP / RGO applied to IgG anti- Toxoplasma gondii antibodies quantitation; Elsevier Science; Talanta; 195; 2019; 699-705 0039-9140 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/ww.sciencedirect.com/science/article/abs/pii/S0039914018312220 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2018.11.070 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844614214386188288 |
score |
13.070432 |