Unifying dose specification between clinical BNCT centers in the Americas
- Autores
- Riley, K. J.; Binns, P. J.; Harling, O. K.; Kiger, W. S.; González, Sara Josefina; Casal, M. R.; Longhino, J.; Calzetta Larrieu, O. A.; Blaumann, Herman Roberto
- Año de publicación
- 2008
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A dosimetry intercomparison between the boron neutron capture therapy groups of the Massachusetts Institute of Technology MIT and the Comisión Nacional de Energía Atómica CNEA, Argentina was performed to enable combined analyses of NCT patient data between the different centers. In-air and dose versus depth measurements in a rectangular water phantom were performed at the hyperthermal neutron beam facility of the RA-6 reactor, Bariloche. Calculated dose profiles from the CNEA treatment planning system NCTPlan that were calibrated against in-house measurements required normalizations of 1.0 thermal neutrons, 1.13 photons, and 0.74 fast neutrons to match the dosimetry of MIT.
Fil: Riley, K. J.. Massachusetts Institute of Technology; Estados Unidos
Fil: Binns, P. J.. Massachusetts Institute of Technology; Estados Unidos
Fil: Harling, O. K.. Massachusetts Institute of Technology; Estados Unidos
Fil: Kiger, W. S.. Harvard Medical School; Estados Unidos
Fil: González, Sara Josefina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica; Argentina
Fil: Casal, M. R.. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Oncología "Ángel H. Roffo"; Argentina
Fil: Longhino, J.. Comisión Nacional de Energía Atómica; Argentina
Fil: Calzetta Larrieu, O. A.. Comisión Nacional de Energía Atómica; Argentina
Fil: Blaumann, Herman Roberto. Comisión Nacional de Energía Atómica; Argentina - Materia
-
BNCT
Dosimetry
Boron - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/282486
Ver los metadatos del registro completo
| id |
CONICETDig_33798f572ad4a501f4d26b400809e889 |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/282486 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
Unifying dose specification between clinical BNCT centers in the AmericasRiley, K. J.Binns, P. J.Harling, O. K.Kiger, W. S.González, Sara JosefinaCasal, M. R.Longhino, J.Calzetta Larrieu, O. A.Blaumann, Herman RobertoBNCTDosimetryBoronhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1A dosimetry intercomparison between the boron neutron capture therapy groups of the Massachusetts Institute of Technology MIT and the Comisión Nacional de Energía Atómica CNEA, Argentina was performed to enable combined analyses of NCT patient data between the different centers. In-air and dose versus depth measurements in a rectangular water phantom were performed at the hyperthermal neutron beam facility of the RA-6 reactor, Bariloche. Calculated dose profiles from the CNEA treatment planning system NCTPlan that were calibrated against in-house measurements required normalizations of 1.0 thermal neutrons, 1.13 photons, and 0.74 fast neutrons to match the dosimetry of MIT.Fil: Riley, K. J.. Massachusetts Institute of Technology; Estados UnidosFil: Binns, P. J.. Massachusetts Institute of Technology; Estados UnidosFil: Harling, O. K.. Massachusetts Institute of Technology; Estados UnidosFil: Kiger, W. S.. Harvard Medical School; Estados UnidosFil: González, Sara Josefina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica; ArgentinaFil: Casal, M. R.. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Oncología "Ángel H. Roffo"; ArgentinaFil: Longhino, J.. Comisión Nacional de Energía Atómica; ArgentinaFil: Calzetta Larrieu, O. A.. Comisión Nacional de Energía Atómica; ArgentinaFil: Blaumann, Herman Roberto. Comisión Nacional de Energía Atómica; ArgentinaAmerican Association of Physicists in Medicine2008-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/282486Riley, K. J.; Binns, P. J.; Harling, O. K.; Kiger, W. S.; González, Sara Josefina; et al.; Unifying dose specification between clinical BNCT centers in the Americas; American Association of Physicists in Medicine; Medical Physics; 35; 4; 4-2008; 1295-12980094-2405CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://aapm.onlinelibrary.wiley.com/doi/10.1118/1.2884856info:eu-repo/semantics/altIdentifier/doi/10.1118/1.2884856info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2026-03-11T13:25:25Zoai:ri.conicet.gov.ar:11336/282486instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982026-03-11 13:25:25.909CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
Unifying dose specification between clinical BNCT centers in the Americas |
| title |
Unifying dose specification between clinical BNCT centers in the Americas |
| spellingShingle |
Unifying dose specification between clinical BNCT centers in the Americas Riley, K. J. BNCT Dosimetry Boron |
| title_short |
Unifying dose specification between clinical BNCT centers in the Americas |
| title_full |
Unifying dose specification between clinical BNCT centers in the Americas |
| title_fullStr |
Unifying dose specification between clinical BNCT centers in the Americas |
| title_full_unstemmed |
Unifying dose specification between clinical BNCT centers in the Americas |
| title_sort |
Unifying dose specification between clinical BNCT centers in the Americas |
| dc.creator.none.fl_str_mv |
Riley, K. J. Binns, P. J. Harling, O. K. Kiger, W. S. González, Sara Josefina Casal, M. R. Longhino, J. Calzetta Larrieu, O. A. Blaumann, Herman Roberto |
| author |
Riley, K. J. |
| author_facet |
Riley, K. J. Binns, P. J. Harling, O. K. Kiger, W. S. González, Sara Josefina Casal, M. R. Longhino, J. Calzetta Larrieu, O. A. Blaumann, Herman Roberto |
| author_role |
author |
| author2 |
Binns, P. J. Harling, O. K. Kiger, W. S. González, Sara Josefina Casal, M. R. Longhino, J. Calzetta Larrieu, O. A. Blaumann, Herman Roberto |
| author2_role |
author author author author author author author author |
| dc.subject.none.fl_str_mv |
BNCT Dosimetry Boron |
| topic |
BNCT Dosimetry Boron |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
| dc.description.none.fl_txt_mv |
A dosimetry intercomparison between the boron neutron capture therapy groups of the Massachusetts Institute of Technology MIT and the Comisión Nacional de Energía Atómica CNEA, Argentina was performed to enable combined analyses of NCT patient data between the different centers. In-air and dose versus depth measurements in a rectangular water phantom were performed at the hyperthermal neutron beam facility of the RA-6 reactor, Bariloche. Calculated dose profiles from the CNEA treatment planning system NCTPlan that were calibrated against in-house measurements required normalizations of 1.0 thermal neutrons, 1.13 photons, and 0.74 fast neutrons to match the dosimetry of MIT. Fil: Riley, K. J.. Massachusetts Institute of Technology; Estados Unidos Fil: Binns, P. J.. Massachusetts Institute of Technology; Estados Unidos Fil: Harling, O. K.. Massachusetts Institute of Technology; Estados Unidos Fil: Kiger, W. S.. Harvard Medical School; Estados Unidos Fil: González, Sara Josefina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica; Argentina Fil: Casal, M. R.. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Oncología "Ángel H. Roffo"; Argentina Fil: Longhino, J.. Comisión Nacional de Energía Atómica; Argentina Fil: Calzetta Larrieu, O. A.. Comisión Nacional de Energía Atómica; Argentina Fil: Blaumann, Herman Roberto. Comisión Nacional de Energía Atómica; Argentina |
| description |
A dosimetry intercomparison between the boron neutron capture therapy groups of the Massachusetts Institute of Technology MIT and the Comisión Nacional de Energía Atómica CNEA, Argentina was performed to enable combined analyses of NCT patient data between the different centers. In-air and dose versus depth measurements in a rectangular water phantom were performed at the hyperthermal neutron beam facility of the RA-6 reactor, Bariloche. Calculated dose profiles from the CNEA treatment planning system NCTPlan that were calibrated against in-house measurements required normalizations of 1.0 thermal neutrons, 1.13 photons, and 0.74 fast neutrons to match the dosimetry of MIT. |
| publishDate |
2008 |
| dc.date.none.fl_str_mv |
2008-04 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/282486 Riley, K. J.; Binns, P. J.; Harling, O. K.; Kiger, W. S.; González, Sara Josefina; et al.; Unifying dose specification between clinical BNCT centers in the Americas; American Association of Physicists in Medicine; Medical Physics; 35; 4; 4-2008; 1295-1298 0094-2405 CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/282486 |
| identifier_str_mv |
Riley, K. J.; Binns, P. J.; Harling, O. K.; Kiger, W. S.; González, Sara Josefina; et al.; Unifying dose specification between clinical BNCT centers in the Americas; American Association of Physicists in Medicine; Medical Physics; 35; 4; 4-2008; 1295-1298 0094-2405 CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://aapm.onlinelibrary.wiley.com/doi/10.1118/1.2884856 info:eu-repo/semantics/altIdentifier/doi/10.1118/1.2884856 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
American Association of Physicists in Medicine |
| publisher.none.fl_str_mv |
American Association of Physicists in Medicine |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1859461097017311232 |
| score |
12.977003 |