Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems
- Autores
- Pellegrini Malpiedi, Luciana; Nerli, Bibiana Beatriz; Taqueda, Maria, E. S.; Abdalla, Dulcineia S. P.; Pessoa Jr., Adalberto
- Año de publicación
- 2015
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- In this work, the purification of a single-chain variable fragment (scFv) of an antibody by using liquid–liquid extraction in aqueous micellar two-phase systems was optimized by means of central composite design. Protein partitioning assays were performed by using the selected system composition in previous works: Triton X-114 at 4% wt/wt, yeast fermentation supernatant at 60% wt/wt, McIlvaine buffer pH 7.00. The other system component concentrations, Cibacron Blue F3GA (CB), Fabsorbent™ F1P HF (HF) and NaCl, were selected as independent variables. ScFv recovery percentage (%R) and purification factor (PF) were selected as the responses. According to the optimization process both, scFv recovery percentage and purification factor were favored with the addition of HF and NaCl in a range of concentrations around the central point of the second central composite design (HF 0.0120% w/w, CB 0.0200% w/w, NaCl 0.200% w/w). These experimental conditions allowed the concentration and pre-purification of scFv in the micelle-rich bottom phase of the systems with a recovery percentage superior to 88% and a purification factor of approximately 3.5. These results improved the previously presented works and demonstrated the convenience of using aqueous micellar two-phase systems as a first step in the purification of scFv molecules.
Fil: Pellegrini Malpiedi, Luciana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; Argentina
Fil: Nerli, Bibiana Beatriz. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; Argentina
Fil: Taqueda, Maria, E. S.. Universidade de Sao Paulo; Brasil
Fil: Abdalla, Dulcineia S. P.. Universidade de Sao Paulo; Brasil
Fil: Pessoa Jr., Adalberto. Universidade de Sao Paulo; Brasil - Materia
-
Antibody Fragments
Aqueous Micellar Two-Phase Systems
Central Composite Design
Surface Response - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/13402
Ver los metadatos del registro completo
id |
CONICETDig_32444340698d7a41921d58503513d84f |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/13402 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systemsPellegrini Malpiedi, LucianaNerli, Bibiana BeatrizTaqueda, Maria, E. S.Abdalla, Dulcineia S. P.Pessoa Jr., AdalbertoAntibody FragmentsAqueous Micellar Two-Phase SystemsCentral Composite DesignSurface Responsehttps://purl.org/becyt/ford/2.11https://purl.org/becyt/ford/2In this work, the purification of a single-chain variable fragment (scFv) of an antibody by using liquid–liquid extraction in aqueous micellar two-phase systems was optimized by means of central composite design. Protein partitioning assays were performed by using the selected system composition in previous works: Triton X-114 at 4% wt/wt, yeast fermentation supernatant at 60% wt/wt, McIlvaine buffer pH 7.00. The other system component concentrations, Cibacron Blue F3GA (CB), Fabsorbent™ F1P HF (HF) and NaCl, were selected as independent variables. ScFv recovery percentage (%R) and purification factor (PF) were selected as the responses. According to the optimization process both, scFv recovery percentage and purification factor were favored with the addition of HF and NaCl in a range of concentrations around the central point of the second central composite design (HF 0.0120% w/w, CB 0.0200% w/w, NaCl 0.200% w/w). These experimental conditions allowed the concentration and pre-purification of scFv in the micelle-rich bottom phase of the systems with a recovery percentage superior to 88% and a purification factor of approximately 3.5. These results improved the previously presented works and demonstrated the convenience of using aqueous micellar two-phase systems as a first step in the purification of scFv molecules.Fil: Pellegrini Malpiedi, Luciana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; ArgentinaFil: Nerli, Bibiana Beatriz. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; ArgentinaFil: Taqueda, Maria, E. S.. Universidade de Sao Paulo; BrasilFil: Abdalla, Dulcineia S. P.. Universidade de Sao Paulo; BrasilFil: Pessoa Jr., Adalberto. Universidade de Sao Paulo; BrasilElsevier Inc2015-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/13402Pellegrini Malpiedi, Luciana; Nerli, Bibiana Beatriz; Taqueda, Maria, E. S.; Abdalla, Dulcineia S. P.; Pessoa Jr., Adalberto; Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems; Elsevier Inc; Protein Expression And Purification; 111; 7-2015; 53-601046-5928enginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.pep.2015.03.014info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S1046592815000716info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T14:22:19Zoai:ri.conicet.gov.ar:11336/13402instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 14:22:20.178CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems |
title |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems |
spellingShingle |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems Pellegrini Malpiedi, Luciana Antibody Fragments Aqueous Micellar Two-Phase Systems Central Composite Design Surface Response |
title_short |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems |
title_full |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems |
title_fullStr |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems |
title_full_unstemmed |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems |
title_sort |
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems |
dc.creator.none.fl_str_mv |
Pellegrini Malpiedi, Luciana Nerli, Bibiana Beatriz Taqueda, Maria, E. S. Abdalla, Dulcineia S. P. Pessoa Jr., Adalberto |
author |
Pellegrini Malpiedi, Luciana |
author_facet |
Pellegrini Malpiedi, Luciana Nerli, Bibiana Beatriz Taqueda, Maria, E. S. Abdalla, Dulcineia S. P. Pessoa Jr., Adalberto |
author_role |
author |
author2 |
Nerli, Bibiana Beatriz Taqueda, Maria, E. S. Abdalla, Dulcineia S. P. Pessoa Jr., Adalberto |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
Antibody Fragments Aqueous Micellar Two-Phase Systems Central Composite Design Surface Response |
topic |
Antibody Fragments Aqueous Micellar Two-Phase Systems Central Composite Design Surface Response |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.11 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
In this work, the purification of a single-chain variable fragment (scFv) of an antibody by using liquid–liquid extraction in aqueous micellar two-phase systems was optimized by means of central composite design. Protein partitioning assays were performed by using the selected system composition in previous works: Triton X-114 at 4% wt/wt, yeast fermentation supernatant at 60% wt/wt, McIlvaine buffer pH 7.00. The other system component concentrations, Cibacron Blue F3GA (CB), Fabsorbent™ F1P HF (HF) and NaCl, were selected as independent variables. ScFv recovery percentage (%R) and purification factor (PF) were selected as the responses. According to the optimization process both, scFv recovery percentage and purification factor were favored with the addition of HF and NaCl in a range of concentrations around the central point of the second central composite design (HF 0.0120% w/w, CB 0.0200% w/w, NaCl 0.200% w/w). These experimental conditions allowed the concentration and pre-purification of scFv in the micelle-rich bottom phase of the systems with a recovery percentage superior to 88% and a purification factor of approximately 3.5. These results improved the previously presented works and demonstrated the convenience of using aqueous micellar two-phase systems as a first step in the purification of scFv molecules. Fil: Pellegrini Malpiedi, Luciana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; Argentina Fil: Nerli, Bibiana Beatriz. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; Argentina Fil: Taqueda, Maria, E. S.. Universidade de Sao Paulo; Brasil Fil: Abdalla, Dulcineia S. P.. Universidade de Sao Paulo; Brasil Fil: Pessoa Jr., Adalberto. Universidade de Sao Paulo; Brasil |
description |
In this work, the purification of a single-chain variable fragment (scFv) of an antibody by using liquid–liquid extraction in aqueous micellar two-phase systems was optimized by means of central composite design. Protein partitioning assays were performed by using the selected system composition in previous works: Triton X-114 at 4% wt/wt, yeast fermentation supernatant at 60% wt/wt, McIlvaine buffer pH 7.00. The other system component concentrations, Cibacron Blue F3GA (CB), Fabsorbent™ F1P HF (HF) and NaCl, were selected as independent variables. ScFv recovery percentage (%R) and purification factor (PF) were selected as the responses. According to the optimization process both, scFv recovery percentage and purification factor were favored with the addition of HF and NaCl in a range of concentrations around the central point of the second central composite design (HF 0.0120% w/w, CB 0.0200% w/w, NaCl 0.200% w/w). These experimental conditions allowed the concentration and pre-purification of scFv in the micelle-rich bottom phase of the systems with a recovery percentage superior to 88% and a purification factor of approximately 3.5. These results improved the previously presented works and demonstrated the convenience of using aqueous micellar two-phase systems as a first step in the purification of scFv molecules. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-07 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/13402 Pellegrini Malpiedi, Luciana; Nerli, Bibiana Beatriz; Taqueda, Maria, E. S.; Abdalla, Dulcineia S. P.; Pessoa Jr., Adalberto; Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems; Elsevier Inc; Protein Expression And Purification; 111; 7-2015; 53-60 1046-5928 |
url |
http://hdl.handle.net/11336/13402 |
identifier_str_mv |
Pellegrini Malpiedi, Luciana; Nerli, Bibiana Beatriz; Taqueda, Maria, E. S.; Abdalla, Dulcineia S. P.; Pessoa Jr., Adalberto; Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems; Elsevier Inc; Protein Expression And Purification; 111; 7-2015; 53-60 1046-5928 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.pep.2015.03.014 info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S1046592815000716 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Inc |
publisher.none.fl_str_mv |
Elsevier Inc |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1846082622215684096 |
score |
13.22299 |