Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds
- Autores
- Rius, Jordi; Vallcorba, Oriol; Crespi, Anna; Colombo, Fernando
- Año de publicación
- 2017
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Successful phasing of synchrotron through-the-substrate microdiffraction data by δ-recycling direct-methods largely depends on the number of missing intensities caused by the limited sample rotation range [J. Rius, Direct phasing from Patterson syntheses by δ recycling. Acta Cryst. A 2012, 68, 77–81]. Particularly, for the unfavorable triclinic system, dataset completeness resulting from a single series of consecutive ϕ-scans covering a total ϕ interval of ±35° is around 41%. This value is not enough for the routinary solution of a crystal structure by δ-recycling but can be increased by ~29% by applying the orthogonal χ strategy consisting of merging the information of two series of orthogonal ϕ-scans collected at the same microvolume of the polished thin section. Test calculations using simulated and experimental tts-data of the triclinic mineral axinite confirm that, with the help of the orthogonal χ strategy, crystal structures can be solved routinely. Since data in the ±35 ϕ-interval are normally accessible even for relatively thick glass-substrates (1–1.5 mm), a crystal structure can be determined from a single microvolume. For high-symmetry phases, due to the Laue symmetry redundancy, a single series of ϕ-scans normally suffices for the application of δ-recycling. However, when for experimental causes this series is incomplete, the orthogonal χ strategy also provides a simple way to increase the completeness which besides allowing solving the structure, is also beneficial for the subsequent refinement.
Fil: Rius, Jordi. Consejo Superior de Investigaciones Científicas. Instituto de Ciencia de los Materiales de Barcelona; España
Fil: Vallcorba, Oriol. ALBA Synchrotron Light Source; España
Fil: Crespi, Anna. Consejo Superior de Investigaciones Científicas. Instituto de Ciencia de los Materiales de Barcelona; España
Fil: Colombo, Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Centro de Investigaciones en Ciencias de la Tierra. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Centro de Investigaciones en Ciencias de la Tierra; Argentina - Materia
-
Recycling Phasing
Polished Thin Sections
Structure Solution
X-Ray Data Completeness - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/44906
Ver los metadatos del registro completo
id |
CONICETDig_27a59f5f5a09f26f51d60811f84093fe |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/44906 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compoundsRius, JordiVallcorba, OriolCrespi, AnnaColombo, FernandoRecycling PhasingPolished Thin SectionsStructure SolutionX-Ray Data Completenesshttps://purl.org/becyt/ford/1.5https://purl.org/becyt/ford/1Successful phasing of synchrotron through-the-substrate microdiffraction data by δ-recycling direct-methods largely depends on the number of missing intensities caused by the limited sample rotation range [J. Rius, Direct phasing from Patterson syntheses by δ recycling. Acta Cryst. A 2012, 68, 77–81]. Particularly, for the unfavorable triclinic system, dataset completeness resulting from a single series of consecutive ϕ-scans covering a total ϕ interval of ±35° is around 41%. This value is not enough for the routinary solution of a crystal structure by δ-recycling but can be increased by ~29% by applying the orthogonal χ strategy consisting of merging the information of two series of orthogonal ϕ-scans collected at the same microvolume of the polished thin section. Test calculations using simulated and experimental tts-data of the triclinic mineral axinite confirm that, with the help of the orthogonal χ strategy, crystal structures can be solved routinely. Since data in the ±35 ϕ-interval are normally accessible even for relatively thick glass-substrates (1–1.5 mm), a crystal structure can be determined from a single microvolume. For high-symmetry phases, due to the Laue symmetry redundancy, a single series of ϕ-scans normally suffices for the application of δ-recycling. However, when for experimental causes this series is incomplete, the orthogonal χ strategy also provides a simple way to increase the completeness which besides allowing solving the structure, is also beneficial for the subsequent refinement.Fil: Rius, Jordi. Consejo Superior de Investigaciones Científicas. Instituto de Ciencia de los Materiales de Barcelona; EspañaFil: Vallcorba, Oriol. ALBA Synchrotron Light Source; EspañaFil: Crespi, Anna. Consejo Superior de Investigaciones Científicas. Instituto de Ciencia de los Materiales de Barcelona; EspañaFil: Colombo, Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Centro de Investigaciones en Ciencias de la Tierra. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Centro de Investigaciones en Ciencias de la Tierra; ArgentinaDe Gruyter2017-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/44906Rius, Jordi; Vallcorba, Oriol; Crespi, Anna; Colombo, Fernando; Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds; De Gruyter; Zeitschrift für Kristallographie Crystalline Materials; 232; 12; 1-2017; 827–8342194-49462196-7105CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.degruyter.com/view/j/zkri.ahead-of-print/zkri-2017-2064/zkri-2017-2064.xmlinfo:eu-repo/semantics/altIdentifier/doi/10.1515/zkri-2017-2064info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:32:54Zoai:ri.conicet.gov.ar:11336/44906instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:32:55.214CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds |
title |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds |
spellingShingle |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds Rius, Jordi Recycling Phasing Polished Thin Sections Structure Solution X-Ray Data Completeness |
title_short |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds |
title_full |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds |
title_fullStr |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds |
title_full_unstemmed |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds |
title_sort |
Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds |
dc.creator.none.fl_str_mv |
Rius, Jordi Vallcorba, Oriol Crespi, Anna Colombo, Fernando |
author |
Rius, Jordi |
author_facet |
Rius, Jordi Vallcorba, Oriol Crespi, Anna Colombo, Fernando |
author_role |
author |
author2 |
Vallcorba, Oriol Crespi, Anna Colombo, Fernando |
author2_role |
author author author |
dc.subject.none.fl_str_mv |
Recycling Phasing Polished Thin Sections Structure Solution X-Ray Data Completeness |
topic |
Recycling Phasing Polished Thin Sections Structure Solution X-Ray Data Completeness |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.5 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
Successful phasing of synchrotron through-the-substrate microdiffraction data by δ-recycling direct-methods largely depends on the number of missing intensities caused by the limited sample rotation range [J. Rius, Direct phasing from Patterson syntheses by δ recycling. Acta Cryst. A 2012, 68, 77–81]. Particularly, for the unfavorable triclinic system, dataset completeness resulting from a single series of consecutive ϕ-scans covering a total ϕ interval of ±35° is around 41%. This value is not enough for the routinary solution of a crystal structure by δ-recycling but can be increased by ~29% by applying the orthogonal χ strategy consisting of merging the information of two series of orthogonal ϕ-scans collected at the same microvolume of the polished thin section. Test calculations using simulated and experimental tts-data of the triclinic mineral axinite confirm that, with the help of the orthogonal χ strategy, crystal structures can be solved routinely. Since data in the ±35 ϕ-interval are normally accessible even for relatively thick glass-substrates (1–1.5 mm), a crystal structure can be determined from a single microvolume. For high-symmetry phases, due to the Laue symmetry redundancy, a single series of ϕ-scans normally suffices for the application of δ-recycling. However, when for experimental causes this series is incomplete, the orthogonal χ strategy also provides a simple way to increase the completeness which besides allowing solving the structure, is also beneficial for the subsequent refinement. Fil: Rius, Jordi. Consejo Superior de Investigaciones Científicas. Instituto de Ciencia de los Materiales de Barcelona; España Fil: Vallcorba, Oriol. ALBA Synchrotron Light Source; España Fil: Crespi, Anna. Consejo Superior de Investigaciones Científicas. Instituto de Ciencia de los Materiales de Barcelona; España Fil: Colombo, Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Centro de Investigaciones en Ciencias de la Tierra. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Centro de Investigaciones en Ciencias de la Tierra; Argentina |
description |
Successful phasing of synchrotron through-the-substrate microdiffraction data by δ-recycling direct-methods largely depends on the number of missing intensities caused by the limited sample rotation range [J. Rius, Direct phasing from Patterson syntheses by δ recycling. Acta Cryst. A 2012, 68, 77–81]. Particularly, for the unfavorable triclinic system, dataset completeness resulting from a single series of consecutive ϕ-scans covering a total ϕ interval of ±35° is around 41%. This value is not enough for the routinary solution of a crystal structure by δ-recycling but can be increased by ~29% by applying the orthogonal χ strategy consisting of merging the information of two series of orthogonal ϕ-scans collected at the same microvolume of the polished thin section. Test calculations using simulated and experimental tts-data of the triclinic mineral axinite confirm that, with the help of the orthogonal χ strategy, crystal structures can be solved routinely. Since data in the ±35 ϕ-interval are normally accessible even for relatively thick glass-substrates (1–1.5 mm), a crystal structure can be determined from a single microvolume. For high-symmetry phases, due to the Laue symmetry redundancy, a single series of ϕ-scans normally suffices for the application of δ-recycling. However, when for experimental causes this series is incomplete, the orthogonal χ strategy also provides a simple way to increase the completeness which besides allowing solving the structure, is also beneficial for the subsequent refinement. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/44906 Rius, Jordi; Vallcorba, Oriol; Crespi, Anna; Colombo, Fernando; Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds; De Gruyter; Zeitschrift für Kristallographie Crystalline Materials; 232; 12; 1-2017; 827–834 2194-4946 2196-7105 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/44906 |
identifier_str_mv |
Rius, Jordi; Vallcorba, Oriol; Crespi, Anna; Colombo, Fernando; Increasing data completeness in synchrotron tts-microdiffraction experiments for δ-recycling phasing of low-symmetry compounds; De Gruyter; Zeitschrift für Kristallographie Crystalline Materials; 232; 12; 1-2017; 827–834 2194-4946 2196-7105 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.degruyter.com/view/j/zkri.ahead-of-print/zkri-2017-2064/zkri-2017-2064.xml info:eu-repo/semantics/altIdentifier/doi/10.1515/zkri-2017-2064 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
De Gruyter |
publisher.none.fl_str_mv |
De Gruyter |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613007518203904 |
score |
13.070432 |