Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars
- Autores
- Sly, Edith Gabriela; Kaplan, Andrea Edith; Missana, Liliana Raquel
- Año de publicación
- 2010
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- The aim of this study was to evaluate the clinical behavior of two conventional glass ionomers used for pit and fissure sealing in terms of retention, marginal adaptation, caries recurrence and cracking. Eighty-three fully erupted first permanent molars were sealed, in a group of children aged 5 to 8 years. A doubleblind, single operator, paired design was used. Materials applied were Fuji IX and VII. Retention (R), presence of caries (PC), marginal discoloration (MD), marginal adaptation (MA) and cracking (C) were evaluated at 6 and 12 months using Ryge’s criteria. Data registered 6 months after treatment were: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. Results after one year were: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. Statistical analysis using Fisher test showed no significant difference (p>0.05) for R, and MA. For PC, MD and C, values are not reported because both materials showed the same results. The second control showed no significant difference (p>0.05) for R, MA, PC, MD and C. Results suggest no difference between Fuji IX and Fuji VII as sealants in fully erupted permanent molars.
El objetivo de este trabajo fue evaluar el comportamiento clinico de dos ionomeros vitreos convencionales aplicados como selladores de fosas y fisuras. Se evaluo la retencion, decoloracion y adaptacion marginal, incidencia de caries y agrietamiento. Se sellaron ochenta y tres primeros molares totalmente erupcionados en un grupo de ninos de 5 a 8 anos. Se llevo a cabo un diseno de doble ciego, unico operador y apareado. Los materiales aplicados fueron Fuji IX y VII. Luego de 6 y 12 meses se recitaron los ninos y se evaluo: Retencion (R), presencia de caries (PC), decoloracion marginal (MD) y agrietamiento (C). La evaluacion se realizo utilizando los criterios de Ryge. Los datos registrados al cabo de 6 meses fueron: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. A los 12 meses: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. La evaluacion estadistica por medio de la prueba de Fisher no mostro diferencias significativas entre los materiales (p>0.05) para R y MA. En PC, MD y C, el valor de p no se indica ya que los resultados fueron identicos. El segundo control no mostro diferencias significativas (p>0.05) para R, MA, PC, MD y C. Los resultados sugieren que no existiria diferencia en la aplicacion de Fuji IX y Fuji VII como selladores de fosas y fisuras en molares totalmente erupcionados.
Fil: Sly, Edith Gabriela. Universidad Nacional de Tucumán. Facultad de Odontología; Argentina
Fil: Kaplan, Andrea Edith. Universidad de Buenos Aires; Argentina
Fil: Missana, Liliana Raquel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Planta Piloto de Procesos Industriales Microbiológicos; Argentina. Universidad Nacional de Tucumán; Argentina - Materia
-
Ionomero Vitreo
Selladores De Fosas y Fisuras - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/38370
Ver los metadatos del registro completo
id |
CONICETDig_1c0fb2bd3b8e2e86f0e2cbad96fa18de |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/38370 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molarsEvaluación clínica de cementos de ionómero vítreo aplicados como selladores de fosas y fisurasSly, Edith GabrielaKaplan, Andrea EdithMissana, Liliana RaquelIonomero VitreoSelladores De Fosas y Fisurashttps://purl.org/becyt/ford/3.3https://purl.org/becyt/ford/3The aim of this study was to evaluate the clinical behavior of two conventional glass ionomers used for pit and fissure sealing in terms of retention, marginal adaptation, caries recurrence and cracking. Eighty-three fully erupted first permanent molars were sealed, in a group of children aged 5 to 8 years. A doubleblind, single operator, paired design was used. Materials applied were Fuji IX and VII. Retention (R), presence of caries (PC), marginal discoloration (MD), marginal adaptation (MA) and cracking (C) were evaluated at 6 and 12 months using Ryge’s criteria. Data registered 6 months after treatment were: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. Results after one year were: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. Statistical analysis using Fisher test showed no significant difference (p>0.05) for R, and MA. For PC, MD and C, values are not reported because both materials showed the same results. The second control showed no significant difference (p>0.05) for R, MA, PC, MD and C. Results suggest no difference between Fuji IX and Fuji VII as sealants in fully erupted permanent molars.El objetivo de este trabajo fue evaluar el comportamiento clinico de dos ionomeros vitreos convencionales aplicados como selladores de fosas y fisuras. Se evaluo la retencion, decoloracion y adaptacion marginal, incidencia de caries y agrietamiento. Se sellaron ochenta y tres primeros molares totalmente erupcionados en un grupo de ninos de 5 a 8 anos. Se llevo a cabo un diseno de doble ciego, unico operador y apareado. Los materiales aplicados fueron Fuji IX y VII. Luego de 6 y 12 meses se recitaron los ninos y se evaluo: Retencion (R), presencia de caries (PC), decoloracion marginal (MD) y agrietamiento (C). La evaluacion se realizo utilizando los criterios de Ryge. Los datos registrados al cabo de 6 meses fueron: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. A los 12 meses: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. La evaluacion estadistica por medio de la prueba de Fisher no mostro diferencias significativas entre los materiales (p>0.05) para R y MA. En PC, MD y C, el valor de p no se indica ya que los resultados fueron identicos. El segundo control no mostro diferencias significativas (p>0.05) para R, MA, PC, MD y C. Los resultados sugieren que no existiria diferencia en la aplicacion de Fuji IX y Fuji VII como selladores de fosas y fisuras en molares totalmente erupcionados.Fil: Sly, Edith Gabriela. Universidad Nacional de Tucumán. Facultad de Odontología; ArgentinaFil: Kaplan, Andrea Edith. Universidad de Buenos Aires; ArgentinaFil: Missana, Liliana Raquel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Planta Piloto de Procesos Industriales Microbiológicos; Argentina. Universidad Nacional de Tucumán; ArgentinaFacultad de Odontología Universidad de Buenos Aires2010-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/38370Sly, Edith Gabriela; Kaplan, Andrea Edith; Missana, Liliana Raquel; Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars; Facultad de Odontología Universidad de Buenos Aires; Acta Odontológica Latinoamericana; 23; 1; 12-2010; 3-70326-4815CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://ref.scielo.org/23cjyfinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T15:28:54Zoai:ri.conicet.gov.ar:11336/38370instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 15:28:55.108CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars Evaluación clínica de cementos de ionómero vítreo aplicados como selladores de fosas y fisuras |
title |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars |
spellingShingle |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars Sly, Edith Gabriela Ionomero Vitreo Selladores De Fosas y Fisuras |
title_short |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars |
title_full |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars |
title_fullStr |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars |
title_full_unstemmed |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars |
title_sort |
Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars |
dc.creator.none.fl_str_mv |
Sly, Edith Gabriela Kaplan, Andrea Edith Missana, Liliana Raquel |
author |
Sly, Edith Gabriela |
author_facet |
Sly, Edith Gabriela Kaplan, Andrea Edith Missana, Liliana Raquel |
author_role |
author |
author2 |
Kaplan, Andrea Edith Missana, Liliana Raquel |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Ionomero Vitreo Selladores De Fosas y Fisuras |
topic |
Ionomero Vitreo Selladores De Fosas y Fisuras |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/3.3 https://purl.org/becyt/ford/3 |
dc.description.none.fl_txt_mv |
The aim of this study was to evaluate the clinical behavior of two conventional glass ionomers used for pit and fissure sealing in terms of retention, marginal adaptation, caries recurrence and cracking. Eighty-three fully erupted first permanent molars were sealed, in a group of children aged 5 to 8 years. A doubleblind, single operator, paired design was used. Materials applied were Fuji IX and VII. Retention (R), presence of caries (PC), marginal discoloration (MD), marginal adaptation (MA) and cracking (C) were evaluated at 6 and 12 months using Ryge’s criteria. Data registered 6 months after treatment were: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. Results after one year were: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. Statistical analysis using Fisher test showed no significant difference (p>0.05) for R, and MA. For PC, MD and C, values are not reported because both materials showed the same results. The second control showed no significant difference (p>0.05) for R, MA, PC, MD and C. Results suggest no difference between Fuji IX and Fuji VII as sealants in fully erupted permanent molars. El objetivo de este trabajo fue evaluar el comportamiento clinico de dos ionomeros vitreos convencionales aplicados como selladores de fosas y fisuras. Se evaluo la retencion, decoloracion y adaptacion marginal, incidencia de caries y agrietamiento. Se sellaron ochenta y tres primeros molares totalmente erupcionados en un grupo de ninos de 5 a 8 anos. Se llevo a cabo un diseno de doble ciego, unico operador y apareado. Los materiales aplicados fueron Fuji IX y VII. Luego de 6 y 12 meses se recitaron los ninos y se evaluo: Retencion (R), presencia de caries (PC), decoloracion marginal (MD) y agrietamiento (C). La evaluacion se realizo utilizando los criterios de Ryge. Los datos registrados al cabo de 6 meses fueron: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. A los 12 meses: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. La evaluacion estadistica por medio de la prueba de Fisher no mostro diferencias significativas entre los materiales (p>0.05) para R y MA. En PC, MD y C, el valor de p no se indica ya que los resultados fueron identicos. El segundo control no mostro diferencias significativas (p>0.05) para R, MA, PC, MD y C. Los resultados sugieren que no existiria diferencia en la aplicacion de Fuji IX y Fuji VII como selladores de fosas y fisuras en molares totalmente erupcionados. Fil: Sly, Edith Gabriela. Universidad Nacional de Tucumán. Facultad de Odontología; Argentina Fil: Kaplan, Andrea Edith. Universidad de Buenos Aires; Argentina Fil: Missana, Liliana Raquel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Planta Piloto de Procesos Industriales Microbiológicos; Argentina. Universidad Nacional de Tucumán; Argentina |
description |
The aim of this study was to evaluate the clinical behavior of two conventional glass ionomers used for pit and fissure sealing in terms of retention, marginal adaptation, caries recurrence and cracking. Eighty-three fully erupted first permanent molars were sealed, in a group of children aged 5 to 8 years. A doubleblind, single operator, paired design was used. Materials applied were Fuji IX and VII. Retention (R), presence of caries (PC), marginal discoloration (MD), marginal adaptation (MA) and cracking (C) were evaluated at 6 and 12 months using Ryge’s criteria. Data registered 6 months after treatment were: Fuji IX: R: Alpha 37, Bravo 2, Charlie: 4; PC: Alpha 43, Bravo: 0; MA: Alpha 38, Bravo: 1; MD: Alpha 39, Bravo: 0, Charlie: 0; C: Alpha 39, Bravo: 0. Fuji VII: R: Alpha 29, Bravo 4, Charlie: 7; PC: Alpha 40, Bravo: 0; MA: Alpha: 34, Bravo: 0; MD: Alpha: 34, Bravo: 0; Charlie: 0; C: Alpha 33, Bravo: 0. Results after one year were: Fuji IX: R: Alpha 33, Bravo: 3, Charlie: 9; PC: Alpha 44, Bravo: 1; MA: Alpha 33, Bravo: 1; MD: Alpha: 34, Bravo: 0, Charlie: 0; C: Alpha: 34, Bravo: 0. Fuji VII: R: Alpha 22, Bravo 4, Charlie: 13, PC: Alpha 40, Bravo: 0; MA: Alpha 23, Bravo: 1; MD: Alpha 23, Bravo: 1, Charlie: 0; C: Alpha 23, Bravo: 1. Statistical analysis using Fisher test showed no significant difference (p>0.05) for R, and MA. For PC, MD and C, values are not reported because both materials showed the same results. The second control showed no significant difference (p>0.05) for R, MA, PC, MD and C. Results suggest no difference between Fuji IX and Fuji VII as sealants in fully erupted permanent molars. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/38370 Sly, Edith Gabriela; Kaplan, Andrea Edith; Missana, Liliana Raquel; Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars; Facultad de Odontología Universidad de Buenos Aires; Acta Odontológica Latinoamericana; 23; 1; 12-2010; 3-7 0326-4815 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/38370 |
identifier_str_mv |
Sly, Edith Gabriela; Kaplan, Andrea Edith; Missana, Liliana Raquel; Clinical evaluation of glass ionomer for pit and fissure sealing of fully erupted molars; Facultad de Odontología Universidad de Buenos Aires; Acta Odontológica Latinoamericana; 23; 1; 12-2010; 3-7 0326-4815 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://ref.scielo.org/23cjyf |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Facultad de Odontología Universidad de Buenos Aires |
publisher.none.fl_str_mv |
Facultad de Odontología Universidad de Buenos Aires |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1846083428921901056 |
score |