Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns
- Autores
- Castells, R. C.; Romero, L. M.; Nardillo, A. M.
- Año de publicación
- 1996
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Retention voluntes of fifteen hydrocarbons were measured in columns containing several concentrations of a commercial poly(perfluoroalkyl ether), Fomblin Y HVAC 140/13, as the stationary phase. Two different type ofpacking were studied: one ofthem employed pre-silylated Chromosorb P AW DMCS as the solid support, and the other type wasprepared by coating the stationary phase on Chromosorb P AW and silylating on-column. On-column silylated columns showed unequivocal symptoms of partial deactivation; retention volumes changed regularly with the contení of stationary phase in pre-silylated columns. Analysis of retention in pre-silylated columns indicates that a mixed mechanism (partition and adsorption on the gas-liquid interface) is operative. Systems hydrocarbon + perfluorocompound show pronounced positive deviations from the ideal behaviour that can be attributed to repulsión between the hydrocarbon and the perfluorocompund segments.
- Materia
-
Ciencias Químicas
Gas chromatography
Poly(perfluoroalkyl ether)
hidrocarbons
adsorption on liquid surfaces
mixed retention - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by/4.0/
- Repositorio
- Institución
- Comisión de Investigaciones Científicas de la Provincia de Buenos Aires
- OAI Identificador
- oai:digital.cic.gba.gob.ar:11746/10373
Ver los metadatos del registro completo
id |
CICBA_35ef99012021103021c6eb011b9e7398 |
---|---|
oai_identifier_str |
oai:digital.cic.gba.gob.ar:11746/10373 |
network_acronym_str |
CICBA |
repository_id_str |
9441 |
network_name_str |
CIC Digital (CICBA) |
spelling |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columnsCastells, R. C.Romero, L. M.Nardillo, A. M.Ciencias QuímicasGas chromatographyPoly(perfluoroalkyl ether)hidrocarbonsadsorption on liquid surfacesmixed retentionRetention voluntes of fifteen hydrocarbons were measured in columns containing several concentrations of a commercial poly(perfluoroalkyl ether), Fomblin Y HVAC 140/13, as the stationary phase. Two different type ofpacking were studied: one ofthem employed pre-silylated Chromosorb P AW DMCS as the solid support, and the other type wasprepared by coating the stationary phase on Chromosorb P AW and silylating on-column. On-column silylated columns showed unequivocal symptoms of partial deactivation; retention volumes changed regularly with the contení of stationary phase in pre-silylated columns. Analysis of retention in pre-silylated columns indicates that a mixed mechanism (partition and adsorption on the gas-liquid interface) is operative. Systems hydrocarbon + perfluorocompound show pronounced positive deviations from the ideal behaviour that can be attributed to repulsión between the hydrocarbon and the perfluorocompund segments.1996info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfhttps://digital.cic.gba.gob.ar/handle/11746/10373enginfo:eu-repo/semantics/altIdentifier/issn/0325-4186info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/reponame:CIC Digital (CICBA)instname:Comisión de Investigaciones Científicas de la Provincia de Buenos Airesinstacron:CICBA2025-09-29T13:39:49Zoai:digital.cic.gba.gob.ar:11746/10373Institucionalhttp://digital.cic.gba.gob.arOrganismo científico-tecnológicoNo correspondehttp://digital.cic.gba.gob.ar/oai/snrdmarisa.degiusti@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:94412025-09-29 13:39:49.564CIC Digital (CICBA) - Comisión de Investigaciones Científicas de la Provincia de Buenos Airesfalse |
dc.title.none.fl_str_mv |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns |
title |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns |
spellingShingle |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns Castells, R. C. Ciencias Químicas Gas chromatography Poly(perfluoroalkyl ether) hidrocarbons adsorption on liquid surfaces mixed retention |
title_short |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns |
title_full |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns |
title_fullStr |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns |
title_full_unstemmed |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns |
title_sort |
Thermodynamic consideration of the retention mechanism in a poly(perfluoroalkyl ether) gas chromatographic stationary phase used in packed columns |
dc.creator.none.fl_str_mv |
Castells, R. C. Romero, L. M. Nardillo, A. M. |
author |
Castells, R. C. |
author_facet |
Castells, R. C. Romero, L. M. Nardillo, A. M. |
author_role |
author |
author2 |
Romero, L. M. Nardillo, A. M. |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Ciencias Químicas Gas chromatography Poly(perfluoroalkyl ether) hidrocarbons adsorption on liquid surfaces mixed retention |
topic |
Ciencias Químicas Gas chromatography Poly(perfluoroalkyl ether) hidrocarbons adsorption on liquid surfaces mixed retention |
dc.description.none.fl_txt_mv |
Retention voluntes of fifteen hydrocarbons were measured in columns containing several concentrations of a commercial poly(perfluoroalkyl ether), Fomblin Y HVAC 140/13, as the stationary phase. Two different type ofpacking were studied: one ofthem employed pre-silylated Chromosorb P AW DMCS as the solid support, and the other type wasprepared by coating the stationary phase on Chromosorb P AW and silylating on-column. On-column silylated columns showed unequivocal symptoms of partial deactivation; retention volumes changed regularly with the contení of stationary phase in pre-silylated columns. Analysis of retention in pre-silylated columns indicates that a mixed mechanism (partition and adsorption on the gas-liquid interface) is operative. Systems hydrocarbon + perfluorocompound show pronounced positive deviations from the ideal behaviour that can be attributed to repulsión between the hydrocarbon and the perfluorocompund segments. |
description |
Retention voluntes of fifteen hydrocarbons were measured in columns containing several concentrations of a commercial poly(perfluoroalkyl ether), Fomblin Y HVAC 140/13, as the stationary phase. Two different type ofpacking were studied: one ofthem employed pre-silylated Chromosorb P AW DMCS as the solid support, and the other type wasprepared by coating the stationary phase on Chromosorb P AW and silylating on-column. On-column silylated columns showed unequivocal symptoms of partial deactivation; retention volumes changed regularly with the contení of stationary phase in pre-silylated columns. Analysis of retention in pre-silylated columns indicates that a mixed mechanism (partition and adsorption on the gas-liquid interface) is operative. Systems hydrocarbon + perfluorocompound show pronounced positive deviations from the ideal behaviour that can be attributed to repulsión between the hydrocarbon and the perfluorocompund segments. |
publishDate |
1996 |
dc.date.none.fl_str_mv |
1996 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://digital.cic.gba.gob.ar/handle/11746/10373 |
url |
https://digital.cic.gba.gob.ar/handle/11746/10373 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/issn/0325-4186 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/4.0/ |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:CIC Digital (CICBA) instname:Comisión de Investigaciones Científicas de la Provincia de Buenos Aires instacron:CICBA |
reponame_str |
CIC Digital (CICBA) |
collection |
CIC Digital (CICBA) |
instname_str |
Comisión de Investigaciones Científicas de la Provincia de Buenos Aires |
instacron_str |
CICBA |
institution |
CICBA |
repository.name.fl_str_mv |
CIC Digital (CICBA) - Comisión de Investigaciones Científicas de la Provincia de Buenos Aires |
repository.mail.fl_str_mv |
marisa.degiusti@sedici.unlp.edu.ar |
_version_ |
1844618578747195392 |
score |