High-resolution TDPAC measurement in K₂ZrF₆

Autores
Martínez, Jorge Alberto; Rodríguez, Agustín Mario; Caracoche, María Cristina; Mercader, Roberto Carlos; López García, Alberto Raúl
Año de publicación
1981
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
A time resolution of 2τ=0.75 ns, achieved with a conventional TDPAC setup with FCs detectors, allowed a determination of the very high electric field gradient at Hf impurity sites in K2ZrF6. Simple theoretical calculations seem to indicate that nearest neighbours are responsible for the interaction observed.
Departamento de Física
Materia
Química
TDPAC setup
FCs detectors
Nivel de accesibilidad
acceso abierto
Condiciones de uso
http://creativecommons.org/licenses/by/4.0/
Repositorio
SEDICI (UNLP)
Institución
Universidad Nacional de La Plata
OAI Identificador
oai:sedici.unlp.edu.ar:10915/132965

id SEDICI_88a6553f2121f4478724d5210a2cc099
oai_identifier_str oai:sedici.unlp.edu.ar:10915/132965
network_acronym_str SEDICI
repository_id_str 1329
network_name_str SEDICI (UNLP)
spelling High-resolution TDPAC measurement in K₂ZrF₆Martínez, Jorge AlbertoRodríguez, Agustín MarioCaracoche, María CristinaMercader, Roberto CarlosLópez García, Alberto RaúlQuímicaTDPAC setupFCs detectorsA time resolution of 2τ=0.75 ns, achieved with a conventional TDPAC setup with FCs detectors, allowed a determination of the very high electric field gradient at Hf impurity sites in K<sub>2</sub>ZrF<sub>6</sub>. Simple theoretical calculations seem to indicate that nearest neighbours are responsible for the interaction observed.Departamento de Física1981info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArticulohttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdf261-264http://sedici.unlp.edu.ar/handle/10915/132965enginfo:eu-repo/semantics/altIdentifier/issn/0304-3843info:eu-repo/semantics/altIdentifier/issn/1572-9540info:eu-repo/semantics/altIdentifier/doi/10.1007/bf01026485info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/Creative Commons Attribution 4.0 International (CC BY 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-10-15T11:23:33Zoai:sedici.unlp.edu.ar:10915/132965Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-10-15 11:23:34.246SEDICI (UNLP) - Universidad Nacional de La Platafalse
dc.title.none.fl_str_mv High-resolution TDPAC measurement in K₂ZrF₆
title High-resolution TDPAC measurement in K₂ZrF₆
spellingShingle High-resolution TDPAC measurement in K₂ZrF₆
Martínez, Jorge Alberto
Química
TDPAC setup
FCs detectors
title_short High-resolution TDPAC measurement in K₂ZrF₆
title_full High-resolution TDPAC measurement in K₂ZrF₆
title_fullStr High-resolution TDPAC measurement in K₂ZrF₆
title_full_unstemmed High-resolution TDPAC measurement in K₂ZrF₆
title_sort High-resolution TDPAC measurement in K₂ZrF₆
dc.creator.none.fl_str_mv Martínez, Jorge Alberto
Rodríguez, Agustín Mario
Caracoche, María Cristina
Mercader, Roberto Carlos
López García, Alberto Raúl
author Martínez, Jorge Alberto
author_facet Martínez, Jorge Alberto
Rodríguez, Agustín Mario
Caracoche, María Cristina
Mercader, Roberto Carlos
López García, Alberto Raúl
author_role author
author2 Rodríguez, Agustín Mario
Caracoche, María Cristina
Mercader, Roberto Carlos
López García, Alberto Raúl
author2_role author
author
author
author
dc.subject.none.fl_str_mv Química
TDPAC setup
FCs detectors
topic Química
TDPAC setup
FCs detectors
dc.description.none.fl_txt_mv A time resolution of 2τ=0.75 ns, achieved with a conventional TDPAC setup with FCs detectors, allowed a determination of the very high electric field gradient at Hf impurity sites in K<sub>2</sub>ZrF<sub>6</sub>. Simple theoretical calculations seem to indicate that nearest neighbours are responsible for the interaction observed.
Departamento de Física
description A time resolution of 2τ=0.75 ns, achieved with a conventional TDPAC setup with FCs detectors, allowed a determination of the very high electric field gradient at Hf impurity sites in K<sub>2</sub>ZrF<sub>6</sub>. Simple theoretical calculations seem to indicate that nearest neighbours are responsible for the interaction observed.
publishDate 1981
dc.date.none.fl_str_mv 1981
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Articulo
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://sedici.unlp.edu.ar/handle/10915/132965
url http://sedici.unlp.edu.ar/handle/10915/132965
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/issn/0304-3843
info:eu-repo/semantics/altIdentifier/issn/1572-9540
info:eu-repo/semantics/altIdentifier/doi/10.1007/bf01026485
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
http://creativecommons.org/licenses/by/4.0/
Creative Commons Attribution 4.0 International (CC BY 4.0)
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by/4.0/
Creative Commons Attribution 4.0 International (CC BY 4.0)
dc.format.none.fl_str_mv application/pdf
261-264
dc.source.none.fl_str_mv reponame:SEDICI (UNLP)
instname:Universidad Nacional de La Plata
instacron:UNLP
reponame_str SEDICI (UNLP)
collection SEDICI (UNLP)
instname_str Universidad Nacional de La Plata
instacron_str UNLP
institution UNLP
repository.name.fl_str_mv SEDICI (UNLP) - Universidad Nacional de La Plata
repository.mail.fl_str_mv alira@sedici.unlp.edu.ar
_version_ 1846064290810822656
score 13.22299