Estimation of stray coupling capacitances in biopotential measurements
- Autores
- Haberman, Marcelo Alejandro; Cassino, Augusto Martín; Spinelli, Enrique Mario
- Año de publicación
- 2011
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Biopotential measurements are very sensitive to electromagnetic interference (EMI) from power-lines. Interference conditions are mainly imposed by electric-field coupling, whose effects can be described by coupling capacitances. The main of them are the patient-to-ground and the patient-to-power-line capacitances, usually denoted as CB and CP, respectively. A technique to estimate these elements and experimental data obtained in different environmental conditions are presented. It was found that CB ranges from hundreds of pF to nF, and CP from hundredths of pF to few pF. The presented technique also lets it know the small amplifier-to-ground and amplifier-to-power-line capacitances. The knowledge of all these capacitances allows estimating the EMI conditions that biopotential amplifiers can be subject to, thus, resulting useful data for specifying their design requirements and constraints in real working conditions.
Facultad de Ingeniería
Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales - Materia
-
Ingeniería
Informática
Power-line interference
Stray coupling capacitance
Electric-field interference
Biopotential amplifiers - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by/4.0/
- Repositorio
- Institución
- Universidad Nacional de La Plata
- OAI Identificador
- oai:sedici.unlp.edu.ar:10915/141429
Ver los metadatos del registro completo
id |
SEDICI_5da6a5c3232efd92cd1237d5d5092335 |
---|---|
oai_identifier_str |
oai:sedici.unlp.edu.ar:10915/141429 |
network_acronym_str |
SEDICI |
repository_id_str |
1329 |
network_name_str |
SEDICI (UNLP) |
spelling |
Estimation of stray coupling capacitances in biopotential measurementsHaberman, Marcelo AlejandroCassino, Augusto MartínSpinelli, Enrique MarioIngenieríaInformáticaPower-line interferenceStray coupling capacitanceElectric-field interferenceBiopotential amplifiersBiopotential measurements are very sensitive to electromagnetic interference (EMI) from power-lines. Interference conditions are mainly imposed by electric-field coupling, whose effects can be described by coupling capacitances. The main of them are the patient-to-ground and the patient-to-power-line capacitances, usually denoted as C<sub>B</sub> and C<sub>P</sub>, respectively. A technique to estimate these elements and experimental data obtained in different environmental conditions are presented. It was found that C<sub>B</sub> ranges from hundreds of pF to nF, and C<sub>P</sub> from hundredths of pF to few pF. The presented technique also lets it know the small amplifier-to-ground and amplifier-to-power-line capacitances. The knowledge of all these capacitances allows estimating the EMI conditions that biopotential amplifiers can be subject to, thus, resulting useful data for specifying their design requirements and constraints in real working conditions.Facultad de IngenieríaInstituto de Investigaciones en Electrónica, Control y Procesamiento de Señales2011-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArticulohttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdf1067-1071http://sedici.unlp.edu.ar/handle/10915/141429enginfo:eu-repo/semantics/altIdentifier/issn/1741-0444info:eu-repo/semantics/altIdentifier/issn/0140-0118info:eu-repo/semantics/altIdentifier/doi/10.1007/s11517-011-0811-6info:eu-repo/semantics/altIdentifier/pmid/21773804info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/Creative Commons Attribution 4.0 International (CC BY 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-09-03T11:04:33Zoai:sedici.unlp.edu.ar:10915/141429Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-09-03 11:04:33.356SEDICI (UNLP) - Universidad Nacional de La Platafalse |
dc.title.none.fl_str_mv |
Estimation of stray coupling capacitances in biopotential measurements |
title |
Estimation of stray coupling capacitances in biopotential measurements |
spellingShingle |
Estimation of stray coupling capacitances in biopotential measurements Haberman, Marcelo Alejandro Ingeniería Informática Power-line interference Stray coupling capacitance Electric-field interference Biopotential amplifiers |
title_short |
Estimation of stray coupling capacitances in biopotential measurements |
title_full |
Estimation of stray coupling capacitances in biopotential measurements |
title_fullStr |
Estimation of stray coupling capacitances in biopotential measurements |
title_full_unstemmed |
Estimation of stray coupling capacitances in biopotential measurements |
title_sort |
Estimation of stray coupling capacitances in biopotential measurements |
dc.creator.none.fl_str_mv |
Haberman, Marcelo Alejandro Cassino, Augusto Martín Spinelli, Enrique Mario |
author |
Haberman, Marcelo Alejandro |
author_facet |
Haberman, Marcelo Alejandro Cassino, Augusto Martín Spinelli, Enrique Mario |
author_role |
author |
author2 |
Cassino, Augusto Martín Spinelli, Enrique Mario |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Ingeniería Informática Power-line interference Stray coupling capacitance Electric-field interference Biopotential amplifiers |
topic |
Ingeniería Informática Power-line interference Stray coupling capacitance Electric-field interference Biopotential amplifiers |
dc.description.none.fl_txt_mv |
Biopotential measurements are very sensitive to electromagnetic interference (EMI) from power-lines. Interference conditions are mainly imposed by electric-field coupling, whose effects can be described by coupling capacitances. The main of them are the patient-to-ground and the patient-to-power-line capacitances, usually denoted as C<sub>B</sub> and C<sub>P</sub>, respectively. A technique to estimate these elements and experimental data obtained in different environmental conditions are presented. It was found that C<sub>B</sub> ranges from hundreds of pF to nF, and C<sub>P</sub> from hundredths of pF to few pF. The presented technique also lets it know the small amplifier-to-ground and amplifier-to-power-line capacitances. The knowledge of all these capacitances allows estimating the EMI conditions that biopotential amplifiers can be subject to, thus, resulting useful data for specifying their design requirements and constraints in real working conditions. Facultad de Ingeniería Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales |
description |
Biopotential measurements are very sensitive to electromagnetic interference (EMI) from power-lines. Interference conditions are mainly imposed by electric-field coupling, whose effects can be described by coupling capacitances. The main of them are the patient-to-ground and the patient-to-power-line capacitances, usually denoted as C<sub>B</sub> and C<sub>P</sub>, respectively. A technique to estimate these elements and experimental data obtained in different environmental conditions are presented. It was found that C<sub>B</sub> ranges from hundreds of pF to nF, and C<sub>P</sub> from hundredths of pF to few pF. The presented technique also lets it know the small amplifier-to-ground and amplifier-to-power-line capacitances. The knowledge of all these capacitances allows estimating the EMI conditions that biopotential amplifiers can be subject to, thus, resulting useful data for specifying their design requirements and constraints in real working conditions. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-09 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Articulo http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://sedici.unlp.edu.ar/handle/10915/141429 |
url |
http://sedici.unlp.edu.ar/handle/10915/141429 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/issn/1741-0444 info:eu-repo/semantics/altIdentifier/issn/0140-0118 info:eu-repo/semantics/altIdentifier/doi/10.1007/s11517-011-0811-6 info:eu-repo/semantics/altIdentifier/pmid/21773804 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/4.0/ Creative Commons Attribution 4.0 International (CC BY 4.0) |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/4.0/ Creative Commons Attribution 4.0 International (CC BY 4.0) |
dc.format.none.fl_str_mv |
application/pdf 1067-1071 |
dc.source.none.fl_str_mv |
reponame:SEDICI (UNLP) instname:Universidad Nacional de La Plata instacron:UNLP |
reponame_str |
SEDICI (UNLP) |
collection |
SEDICI (UNLP) |
instname_str |
Universidad Nacional de La Plata |
instacron_str |
UNLP |
institution |
UNLP |
repository.name.fl_str_mv |
SEDICI (UNLP) - Universidad Nacional de La Plata |
repository.mail.fl_str_mv |
alira@sedici.unlp.edu.ar |
_version_ |
1842260543952388096 |
score |
13.13397 |