Wind loads on buildings with vaulted roofs and side walls : a review
- Autores
- Natalini, Mario Bruno
- Año de publicación
- 2017
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Fil: Natalini, Bruno. Universidad Nacional del Nordeste. Facultad de Ingeniería; Argentina.
Fil: Natalini, Bruno. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Nordeste; Argentina.
Fil: Natalini, Mario Bruno. Universidad Nacional del Nordeste. Facultad de Ingeniería; Argentina.
The recommendations of the Argentinean code of practice CIRSOC 102 concerning wind loads on enclosed buildings with curved roofs are identical to those of ASCE 7, which are based on results published in 1914. Significant differences can thus be expected if this treatment is compared with an updated bibliography. This paper reviews the information available in the open literature, including a number of significant studies written in Portuguese that are not readily accessible, with the CIRSOC 102 treatment then compared with state-of-the- art results. The need to update the code is shown, possible criteria and values are suggested, and research needs are listed. - Fuente
- Journal of Wind Engineering and Industrial Aerodynamics, 2017, vol. 161, p. 9-16.
- Materia
-
Wind loads
Curved roofs
Enclosed buildings
Codification - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Universidad Nacional del Nordeste
- OAI Identificador
- oai:repositorio.unne.edu.ar:123456789/30787
Ver los metadatos del registro completo
id |
RIUNNE_8caa320c837a4689d33f0e9eccafc172 |
---|---|
oai_identifier_str |
oai:repositorio.unne.edu.ar:123456789/30787 |
network_acronym_str |
RIUNNE |
repository_id_str |
4871 |
network_name_str |
Repositorio Institucional de la Universidad Nacional del Nordeste (UNNE) |
spelling |
Wind loads on buildings with vaulted roofs and side walls : a reviewNatalini, Mario BrunoWind loadsCurved roofsEnclosed buildingsCodificationFil: Natalini, Bruno. Universidad Nacional del Nordeste. Facultad de Ingeniería; Argentina.Fil: Natalini, Bruno. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Nordeste; Argentina.Fil: Natalini, Mario Bruno. Universidad Nacional del Nordeste. Facultad de Ingeniería; Argentina.The recommendations of the Argentinean code of practice CIRSOC 102 concerning wind loads on enclosed buildings with curved roofs are identical to those of ASCE 7, which are based on results published in 1914. Significant differences can thus be expected if this treatment is compared with an updated bibliography. This paper reviews the information available in the open literature, including a number of significant studies written in Portuguese that are not readily accessible, with the CIRSOC 102 treatment then compared with state-of-the- art results. The need to update the code is shown, possible criteria and values are suggested, and research needs are listed.Elsevier2017-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfNatalini, Mario Bruno, 2017. Wind loads on buildings with vaulted roofs and side walls: a review. Journal of Wind Engineering and Industrial Aerodynamics. Ámsterdam: Elsevier, vol. 161, p. 9-16. ISSN 0167-6105.0167-6105http://repositorio.unne.edu.ar/handle/123456789/30787Journal of Wind Engineering and Industrial Aerodynamics, 2017, vol. 161, p. 9-16.reponame:Repositorio Institucional de la Universidad Nacional del Nordeste (UNNE)instname:Universidad Nacional del Nordesteenghttp://dx.doi.org/10.1016/j.jweia.2016.12.004info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/ar/Atribución-NoComercial-SinDerivadas 2.5 Argentina2025-09-04T11:14:09Zoai:repositorio.unne.edu.ar:123456789/30787instacron:UNNEInstitucionalhttp://repositorio.unne.edu.ar/Universidad públicaNo correspondehttp://repositorio.unne.edu.ar/oaiososa@bib.unne.edu.ar;sergio.alegria@unne.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:48712025-09-04 11:14:10.091Repositorio Institucional de la Universidad Nacional del Nordeste (UNNE) - Universidad Nacional del Nordestefalse |
dc.title.none.fl_str_mv |
Wind loads on buildings with vaulted roofs and side walls : a review |
title |
Wind loads on buildings with vaulted roofs and side walls : a review |
spellingShingle |
Wind loads on buildings with vaulted roofs and side walls : a review Natalini, Mario Bruno Wind loads Curved roofs Enclosed buildings Codification |
title_short |
Wind loads on buildings with vaulted roofs and side walls : a review |
title_full |
Wind loads on buildings with vaulted roofs and side walls : a review |
title_fullStr |
Wind loads on buildings with vaulted roofs and side walls : a review |
title_full_unstemmed |
Wind loads on buildings with vaulted roofs and side walls : a review |
title_sort |
Wind loads on buildings with vaulted roofs and side walls : a review |
dc.creator.none.fl_str_mv |
Natalini, Mario Bruno |
author |
Natalini, Mario Bruno |
author_facet |
Natalini, Mario Bruno |
author_role |
author |
dc.subject.none.fl_str_mv |
Wind loads Curved roofs Enclosed buildings Codification |
topic |
Wind loads Curved roofs Enclosed buildings Codification |
dc.description.none.fl_txt_mv |
Fil: Natalini, Bruno. Universidad Nacional del Nordeste. Facultad de Ingeniería; Argentina. Fil: Natalini, Bruno. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Nordeste; Argentina. Fil: Natalini, Mario Bruno. Universidad Nacional del Nordeste. Facultad de Ingeniería; Argentina. The recommendations of the Argentinean code of practice CIRSOC 102 concerning wind loads on enclosed buildings with curved roofs are identical to those of ASCE 7, which are based on results published in 1914. Significant differences can thus be expected if this treatment is compared with an updated bibliography. This paper reviews the information available in the open literature, including a number of significant studies written in Portuguese that are not readily accessible, with the CIRSOC 102 treatment then compared with state-of-the- art results. The need to update the code is shown, possible criteria and values are suggested, and research needs are listed. |
description |
Fil: Natalini, Bruno. Universidad Nacional del Nordeste. Facultad de Ingeniería; Argentina. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-02 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
Natalini, Mario Bruno, 2017. Wind loads on buildings with vaulted roofs and side walls: a review. Journal of Wind Engineering and Industrial Aerodynamics. Ámsterdam: Elsevier, vol. 161, p. 9-16. ISSN 0167-6105. 0167-6105 http://repositorio.unne.edu.ar/handle/123456789/30787 |
identifier_str_mv |
Natalini, Mario Bruno, 2017. Wind loads on buildings with vaulted roofs and side walls: a review. Journal of Wind Engineering and Industrial Aerodynamics. Ámsterdam: Elsevier, vol. 161, p. 9-16. ISSN 0167-6105. 0167-6105 |
url |
http://repositorio.unne.edu.ar/handle/123456789/30787 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://dx.doi.org/10.1016/j.jweia.2016.12.004 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-nd/2.5/ar/ Atribución-NoComercial-SinDerivadas 2.5 Argentina |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/ar/ Atribución-NoComercial-SinDerivadas 2.5 Argentina |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
Journal of Wind Engineering and Industrial Aerodynamics, 2017, vol. 161, p. 9-16. reponame:Repositorio Institucional de la Universidad Nacional del Nordeste (UNNE) instname:Universidad Nacional del Nordeste |
reponame_str |
Repositorio Institucional de la Universidad Nacional del Nordeste (UNNE) |
collection |
Repositorio Institucional de la Universidad Nacional del Nordeste (UNNE) |
instname_str |
Universidad Nacional del Nordeste |
repository.name.fl_str_mv |
Repositorio Institucional de la Universidad Nacional del Nordeste (UNNE) - Universidad Nacional del Nordeste |
repository.mail.fl_str_mv |
ososa@bib.unne.edu.ar;sergio.alegria@unne.edu.ar |
_version_ |
1842344215053336576 |
score |
12.623145 |