Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy

Autores
Brambilla, Emilio Cesar; Cseh, Susana Beatriz; Fernandez, Eduardo Luján; San Martino, Silvina
Año de publicación
2021
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Selenium (Se) is a trace element used by multiple enzymes. In ruminants, Se present in food is released to ruminal fluid allowing its absorption in the small intestine. Se release may be analysed by hydride generation atomic absorption spectroscopy (HG-AAS). According to the Association Official of Analytical Chemists (AOAC), analysing the methodological performances is important to support the results of a methodology. The aim of this study was to develop and verify the analytical methodology of Se determination in ruminal fluid by HG-AAS. According to the AOAC guide, the parameters to be analyzed, and their respective acceptance criteria (AC) are: applicable range (AC: 0.220 - 9.68 µg/l), bias (AC: 70-125%), precision by repeatability (RSDr%) (AC: < 21%), intermediate precision (RSDip%) (AC: < 21%), recovery (AC: 80-110%), limit of detection (LOD) (AC: < 0.22 µg/l), and relative uncertainty (AC: <15%). The technique used is based on a wet digestion of ruminal fluid with HClO4 , H2 SO4 and HNO3 concentrated at temperatures ranging from 120°C to 180°C. Then the digest was pre-reduced in HCl at 50 % and was quantified in the HG-AAS. The results obtained were: LOD 0.196 µg/l, bias 96.8% (1.25 µg/l); 98.3% (2.50 µg/l); 94.8% (5.00 µg/l), precision by repeatability 8.61% (3.28 µg/l); 8.90 % (3.52 µg/l); 9.80% (1.85 µg/l), intermediate precision RDSip 10.2%, recovery 109.2% (10 µg/l); 96.7% (25 µg/l); 96.8% (50 µg/l) and applicable range 0.196-62.5 µg/l. The values obtained are within the requirements stated by the AC.
El selenio (Se) es un elemento traza utilizado por múltiples enzimas. En rumiantes, el Se de los alimentos es liberado hacia el licor ruminal y esto permite su absorción en el intestino delgado. El Se liberado puede ser analizado por espectrofotometría de absorción atómica con plataforma de hidruros (HG-AAS) De acuerdo con la asociación oficial de química analítica (AOAC) analizar la performance metodológica es importante para respaldar los resultados de una metodología. El objetivo de este estudio fue el desarrollo y verificación de la metodología analítica de la determinación de Se en fluido ruminal mediante un HG-AAS. De acuerdo con la guía de la AOAC, los parámetros para analizar para esto, y sus respectivos criterios de aceptación (CA), son: rango aplicable (CA: 0,22-9,68 µg/l), bias (CA: 70-125%), precisión por repetibilidad (CA: RSDr <21%), precisión intermedia (CA: RSDR <21%), recuperación (CA: 80-110%) y límite de detección (LOD) (CA: <0,22 µg/l), incertidumbre relativa expandida (CA: <15%). La técnica que se utilizó se basó en una digestión húmeda del fluido ruminal con HClO4 (c), H2 SO4 (c) y HNO3 (c) a temperaturas que van de los 120 o C a 180 o C. Luego se realiza una prerreducción del equis con HCl al 50% y se cuantificó en el HG-AAS. Los resultados obtenidos fueron los siguientes: LOD 0,196 µg/l, Bias 96,8% (1,25 µg/l); 98,3% (2,50 µg/l); 94,8% (5,00 µg/l), equisite por repetibilidad 8,61% (3,28 µg/l); 8,90% (3,52 µg/l); 9,80% (1,85 µg/l), equisite intermedia RDSR 10,2%, recuperación 109, 2% (10 µg/l); 96,7% (25 µg/l); 96,8% (50 µg/l) y rango equisites 0.196-62,5 µg/l. Los valores obtenidos están dentro de los equisites mínimos indicados por los CA.
EEA Balcarce
Fil: Brambilla, Emilio Cesar. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; Argentina
Fil: Cseh, Susana Beatriz. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; Argentina
Fil: Fernandez, Eduardo Luján. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; Argentina
Fil: San Martino, Silvina. Universidad Nacional de Mar del Plata. Facultad de Ciencias Agrarias. Departamento de Introducción a las Ciencias Agrarias. Estadística y Diseño Experimental; Argentina
Fuente
RIA 47 (1) : 104-109 (Abril 2021)
Materia
Ganado Bovino
Selenio
Oligoelementos
Espectrometría
Cattle
Selenium
Trace Elements
Spectrometry
Nivel de accesibilidad
acceso abierto
Condiciones de uso
http://creativecommons.org/licenses/by-nc-sa/4.0/
Repositorio
INTA Digital (INTA)
Institución
Instituto Nacional de Tecnología Agropecuaria
OAI Identificador
oai:localhost:20.500.12123/9227

id INTADig_0ebe597ca36cf2cb9c64574e68ba18c5
oai_identifier_str oai:localhost:20.500.12123/9227
network_acronym_str INTADig
repository_id_str l
network_name_str INTA Digital (INTA)
spelling Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopyBrambilla, Emilio CesarCseh, Susana BeatrizFernandez, Eduardo LujánSan Martino, SilvinaGanado BovinoSelenioOligoelementosEspectrometríaCattleSeleniumTrace ElementsSpectrometrySelenium (Se) is a trace element used by multiple enzymes. In ruminants, Se present in food is released to ruminal fluid allowing its absorption in the small intestine. Se release may be analysed by hydride generation atomic absorption spectroscopy (HG-AAS). According to the Association Official of Analytical Chemists (AOAC), analysing the methodological performances is important to support the results of a methodology. The aim of this study was to develop and verify the analytical methodology of Se determination in ruminal fluid by HG-AAS. According to the AOAC guide, the parameters to be analyzed, and their respective acceptance criteria (AC) are: applicable range (AC: 0.220 - 9.68 µg/l), bias (AC: 70-125%), precision by repeatability (RSDr%) (AC: < 21%), intermediate precision (RSDip%) (AC: < 21%), recovery (AC: 80-110%), limit of detection (LOD) (AC: < 0.22 µg/l), and relative uncertainty (AC: <15%). The technique used is based on a wet digestion of ruminal fluid with HClO4 , H2 SO4 and HNO3 concentrated at temperatures ranging from 120°C to 180°C. Then the digest was pre-reduced in HCl at 50 % and was quantified in the HG-AAS. The results obtained were: LOD 0.196 µg/l, bias 96.8% (1.25 µg/l); 98.3% (2.50 µg/l); 94.8% (5.00 µg/l), precision by repeatability 8.61% (3.28 µg/l); 8.90 % (3.52 µg/l); 9.80% (1.85 µg/l), intermediate precision RDSip 10.2%, recovery 109.2% (10 µg/l); 96.7% (25 µg/l); 96.8% (50 µg/l) and applicable range 0.196-62.5 µg/l. The values obtained are within the requirements stated by the AC.El selenio (Se) es un elemento traza utilizado por múltiples enzimas. En rumiantes, el Se de los alimentos es liberado hacia el licor ruminal y esto permite su absorción en el intestino delgado. El Se liberado puede ser analizado por espectrofotometría de absorción atómica con plataforma de hidruros (HG-AAS) De acuerdo con la asociación oficial de química analítica (AOAC) analizar la performance metodológica es importante para respaldar los resultados de una metodología. El objetivo de este estudio fue el desarrollo y verificación de la metodología analítica de la determinación de Se en fluido ruminal mediante un HG-AAS. De acuerdo con la guía de la AOAC, los parámetros para analizar para esto, y sus respectivos criterios de aceptación (CA), son: rango aplicable (CA: 0,22-9,68 µg/l), bias (CA: 70-125%), precisión por repetibilidad (CA: RSDr <21%), precisión intermedia (CA: RSDR <21%), recuperación (CA: 80-110%) y límite de detección (LOD) (CA: <0,22 µg/l), incertidumbre relativa expandida (CA: <15%). La técnica que se utilizó se basó en una digestión húmeda del fluido ruminal con HClO4 (c), H2 SO4 (c) y HNO3 (c) a temperaturas que van de los 120 o C a 180 o C. Luego se realiza una prerreducción del equis con HCl al 50% y se cuantificó en el HG-AAS. Los resultados obtenidos fueron los siguientes: LOD 0,196 µg/l, Bias 96,8% (1,25 µg/l); 98,3% (2,50 µg/l); 94,8% (5,00 µg/l), equisite por repetibilidad 8,61% (3,28 µg/l); 8,90% (3,52 µg/l); 9,80% (1,85 µg/l), equisite intermedia RDSR 10,2%, recuperación 109, 2% (10 µg/l); 96,7% (25 µg/l); 96,8% (50 µg/l) y rango equisites 0.196-62,5 µg/l. Los valores obtenidos están dentro de los equisites mínimos indicados por los CA.EEA BalcarceFil: Brambilla, Emilio Cesar. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; ArgentinaFil: Cseh, Susana Beatriz. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; ArgentinaFil: Fernandez, Eduardo Luján. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; ArgentinaFil: San Martino, Silvina. Universidad Nacional de Mar del Plata. Facultad de Ciencias Agrarias. Departamento de Introducción a las Ciencias Agrarias. Estadística y Diseño Experimental; ArgentinaEdiciones INTA2021-04-29T17:31:31Z2021-04-29T17:31:31Z2021-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfhttp://hdl.handle.net/20.500.12123/92270325-87181669-2314RIA 47 (1) : 104-109 (Abril 2021)reponame:INTA Digital (INTA)instname:Instituto Nacional de Tecnología Agropecuariaenginfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-sa/4.0/Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)2025-10-16T09:30:04Zoai:localhost:20.500.12123/9227instacron:INTAInstitucionalhttp://repositorio.inta.gob.ar/Organismo científico-tecnológicoNo correspondehttp://repositorio.inta.gob.ar/oai/requesttripaldi.nicolas@inta.gob.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:l2025-10-16 09:30:05.169INTA Digital (INTA) - Instituto Nacional de Tecnología Agropecuariafalse
dc.title.none.fl_str_mv Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
title Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
spellingShingle Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
Brambilla, Emilio Cesar
Ganado Bovino
Selenio
Oligoelementos
Espectrometría
Cattle
Selenium
Trace Elements
Spectrometry
title_short Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
title_full Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
title_fullStr Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
title_full_unstemmed Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
title_sort Methodological performance of selenium determination in ruminal fluid by hydride generation atomic absorption spectroscopy
dc.creator.none.fl_str_mv Brambilla, Emilio Cesar
Cseh, Susana Beatriz
Fernandez, Eduardo Luján
San Martino, Silvina
author Brambilla, Emilio Cesar
author_facet Brambilla, Emilio Cesar
Cseh, Susana Beatriz
Fernandez, Eduardo Luján
San Martino, Silvina
author_role author
author2 Cseh, Susana Beatriz
Fernandez, Eduardo Luján
San Martino, Silvina
author2_role author
author
author
dc.subject.none.fl_str_mv Ganado Bovino
Selenio
Oligoelementos
Espectrometría
Cattle
Selenium
Trace Elements
Spectrometry
topic Ganado Bovino
Selenio
Oligoelementos
Espectrometría
Cattle
Selenium
Trace Elements
Spectrometry
dc.description.none.fl_txt_mv Selenium (Se) is a trace element used by multiple enzymes. In ruminants, Se present in food is released to ruminal fluid allowing its absorption in the small intestine. Se release may be analysed by hydride generation atomic absorption spectroscopy (HG-AAS). According to the Association Official of Analytical Chemists (AOAC), analysing the methodological performances is important to support the results of a methodology. The aim of this study was to develop and verify the analytical methodology of Se determination in ruminal fluid by HG-AAS. According to the AOAC guide, the parameters to be analyzed, and their respective acceptance criteria (AC) are: applicable range (AC: 0.220 - 9.68 µg/l), bias (AC: 70-125%), precision by repeatability (RSDr%) (AC: < 21%), intermediate precision (RSDip%) (AC: < 21%), recovery (AC: 80-110%), limit of detection (LOD) (AC: < 0.22 µg/l), and relative uncertainty (AC: <15%). The technique used is based on a wet digestion of ruminal fluid with HClO4 , H2 SO4 and HNO3 concentrated at temperatures ranging from 120°C to 180°C. Then the digest was pre-reduced in HCl at 50 % and was quantified in the HG-AAS. The results obtained were: LOD 0.196 µg/l, bias 96.8% (1.25 µg/l); 98.3% (2.50 µg/l); 94.8% (5.00 µg/l), precision by repeatability 8.61% (3.28 µg/l); 8.90 % (3.52 µg/l); 9.80% (1.85 µg/l), intermediate precision RDSip 10.2%, recovery 109.2% (10 µg/l); 96.7% (25 µg/l); 96.8% (50 µg/l) and applicable range 0.196-62.5 µg/l. The values obtained are within the requirements stated by the AC.
El selenio (Se) es un elemento traza utilizado por múltiples enzimas. En rumiantes, el Se de los alimentos es liberado hacia el licor ruminal y esto permite su absorción en el intestino delgado. El Se liberado puede ser analizado por espectrofotometría de absorción atómica con plataforma de hidruros (HG-AAS) De acuerdo con la asociación oficial de química analítica (AOAC) analizar la performance metodológica es importante para respaldar los resultados de una metodología. El objetivo de este estudio fue el desarrollo y verificación de la metodología analítica de la determinación de Se en fluido ruminal mediante un HG-AAS. De acuerdo con la guía de la AOAC, los parámetros para analizar para esto, y sus respectivos criterios de aceptación (CA), son: rango aplicable (CA: 0,22-9,68 µg/l), bias (CA: 70-125%), precisión por repetibilidad (CA: RSDr <21%), precisión intermedia (CA: RSDR <21%), recuperación (CA: 80-110%) y límite de detección (LOD) (CA: <0,22 µg/l), incertidumbre relativa expandida (CA: <15%). La técnica que se utilizó se basó en una digestión húmeda del fluido ruminal con HClO4 (c), H2 SO4 (c) y HNO3 (c) a temperaturas que van de los 120 o C a 180 o C. Luego se realiza una prerreducción del equis con HCl al 50% y se cuantificó en el HG-AAS. Los resultados obtenidos fueron los siguientes: LOD 0,196 µg/l, Bias 96,8% (1,25 µg/l); 98,3% (2,50 µg/l); 94,8% (5,00 µg/l), equisite por repetibilidad 8,61% (3,28 µg/l); 8,90% (3,52 µg/l); 9,80% (1,85 µg/l), equisite intermedia RDSR 10,2%, recuperación 109, 2% (10 µg/l); 96,7% (25 µg/l); 96,8% (50 µg/l) y rango equisites 0.196-62,5 µg/l. Los valores obtenidos están dentro de los equisites mínimos indicados por los CA.
EEA Balcarce
Fil: Brambilla, Emilio Cesar. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; Argentina
Fil: Cseh, Susana Beatriz. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; Argentina
Fil: Fernandez, Eduardo Luján. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Balcarce; Argentina
Fil: San Martino, Silvina. Universidad Nacional de Mar del Plata. Facultad de Ciencias Agrarias. Departamento de Introducción a las Ciencias Agrarias. Estadística y Diseño Experimental; Argentina
description Selenium (Se) is a trace element used by multiple enzymes. In ruminants, Se present in food is released to ruminal fluid allowing its absorption in the small intestine. Se release may be analysed by hydride generation atomic absorption spectroscopy (HG-AAS). According to the Association Official of Analytical Chemists (AOAC), analysing the methodological performances is important to support the results of a methodology. The aim of this study was to develop and verify the analytical methodology of Se determination in ruminal fluid by HG-AAS. According to the AOAC guide, the parameters to be analyzed, and their respective acceptance criteria (AC) are: applicable range (AC: 0.220 - 9.68 µg/l), bias (AC: 70-125%), precision by repeatability (RSDr%) (AC: < 21%), intermediate precision (RSDip%) (AC: < 21%), recovery (AC: 80-110%), limit of detection (LOD) (AC: < 0.22 µg/l), and relative uncertainty (AC: <15%). The technique used is based on a wet digestion of ruminal fluid with HClO4 , H2 SO4 and HNO3 concentrated at temperatures ranging from 120°C to 180°C. Then the digest was pre-reduced in HCl at 50 % and was quantified in the HG-AAS. The results obtained were: LOD 0.196 µg/l, bias 96.8% (1.25 µg/l); 98.3% (2.50 µg/l); 94.8% (5.00 µg/l), precision by repeatability 8.61% (3.28 µg/l); 8.90 % (3.52 µg/l); 9.80% (1.85 µg/l), intermediate precision RDSip 10.2%, recovery 109.2% (10 µg/l); 96.7% (25 µg/l); 96.8% (50 µg/l) and applicable range 0.196-62.5 µg/l. The values obtained are within the requirements stated by the AC.
publishDate 2021
dc.date.none.fl_str_mv 2021-04-29T17:31:31Z
2021-04-29T17:31:31Z
2021-04
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/20.500.12123/9227
0325-8718
1669-2314
url http://hdl.handle.net/20.500.12123/9227
identifier_str_mv 0325-8718
1669-2314
dc.language.none.fl_str_mv eng
language eng
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
http://creativecommons.org/licenses/by-nc-sa/4.0/
Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-sa/4.0/
Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Ediciones INTA
publisher.none.fl_str_mv Ediciones INTA
dc.source.none.fl_str_mv RIA 47 (1) : 104-109 (Abril 2021)
reponame:INTA Digital (INTA)
instname:Instituto Nacional de Tecnología Agropecuaria
reponame_str INTA Digital (INTA)
collection INTA Digital (INTA)
instname_str Instituto Nacional de Tecnología Agropecuaria
repository.name.fl_str_mv INTA Digital (INTA) - Instituto Nacional de Tecnología Agropecuaria
repository.mail.fl_str_mv tripaldi.nicolas@inta.gob.ar
_version_ 1846143534361477120
score 12.712165