In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids
- Autores
- Venegas, Constanza J.; Gutierrez, Fabiana Andrea; Reeves McLaren, Nik; Rivas, Gustavo Adolfo; Ruiz León, Domingo; Bollo, Soledad
- Año de publicación
- 2023
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Nowadays, there is no doubt about the high electrocatalytic efficiency that is obtained when using hybrid materials between carbonaceous nanomaterials and transition metal oxides. However, the method to prepare them may involve differences in the observed analytical responses, making it necessary to evaluate them for each new material. The goal of this work was to obtain for the first time Co2SnO4 (CSO)/RGO nanohybrids via in situ and ex situ methods and to evaluate their performance in the amperometric detection of hydrogen peroxide. The electroanalytical response was evaluated in NaOH pH 12 solution using detection potentials of −0.400 V or 0.300 V for the reduction or oxidation of H2O2. The results show that for CSO there were no differences between the nanohybrids either by oxidation or by reduction, unlike what we previously observed with cobalt titanate hybrids, in which the in situ nanohybrid clearly had the best performance. On the other hand, no influence in the study of interferents and more stable signals were obtained when the reduction mode was used. In conclusion, for detecting hydrogen peroxide, any of the nanohybrids studied, i.e., in situ or ex situ, are suitable to be used, and more efficiency is obtained using the reduction mode.
Fil: Venegas, Constanza J.. Universidad Tecnologica Metropolitana (utem);
Fil: Gutierrez, Fabiana Andrea. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas. Laboratorio de Desarrollo Analítico y Quimiometría; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
Fil: Reeves McLaren, Nik. University Of Sheffield (university Of Sheffield);
Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
Fil: Ruiz León, Domingo. Universidad de Santiago de Chile; Chile
Fil: Bollo, Soledad. Universidad de Chile.; Chile - Materia
-
CO2SNO4
ELECTROCHEMICAL DETECTION
NANOHYBRIDS
REDUCED GRAPHENE OXIDE - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/224976
Ver los metadatos del registro completo
id |
CONICETDig_ff82c2fc854285830e9ee86ac213b4aa |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/224976 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO NanohybridsVenegas, Constanza J.Gutierrez, Fabiana AndreaReeves McLaren, NikRivas, Gustavo AdolfoRuiz León, DomingoBollo, SoledadCO2SNO4ELECTROCHEMICAL DETECTIONNANOHYBRIDSREDUCED GRAPHENE OXIDEhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1Nowadays, there is no doubt about the high electrocatalytic efficiency that is obtained when using hybrid materials between carbonaceous nanomaterials and transition metal oxides. However, the method to prepare them may involve differences in the observed analytical responses, making it necessary to evaluate them for each new material. The goal of this work was to obtain for the first time Co2SnO4 (CSO)/RGO nanohybrids via in situ and ex situ methods and to evaluate their performance in the amperometric detection of hydrogen peroxide. The electroanalytical response was evaluated in NaOH pH 12 solution using detection potentials of −0.400 V or 0.300 V for the reduction or oxidation of H2O2. The results show that for CSO there were no differences between the nanohybrids either by oxidation or by reduction, unlike what we previously observed with cobalt titanate hybrids, in which the in situ nanohybrid clearly had the best performance. On the other hand, no influence in the study of interferents and more stable signals were obtained when the reduction mode was used. In conclusion, for detecting hydrogen peroxide, any of the nanohybrids studied, i.e., in situ or ex situ, are suitable to be used, and more efficiency is obtained using the reduction mode.Fil: Venegas, Constanza J.. Universidad Tecnologica Metropolitana (utem);Fil: Gutierrez, Fabiana Andrea. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas. Laboratorio de Desarrollo Analítico y Quimiometría; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; ArgentinaFil: Reeves McLaren, Nik. University Of Sheffield (university Of Sheffield);Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Ruiz León, Domingo. Universidad de Santiago de Chile; ChileFil: Bollo, Soledad. Universidad de Chile.; ChileMDPI2023-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/224976Venegas, Constanza J.; Gutierrez, Fabiana Andrea; Reeves McLaren, Nik; Rivas, Gustavo Adolfo; Ruiz León, Domingo; et al.; In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids; MDPI; Micromachines; 14; 5; 5-2023; 1-112072-666XCONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.mdpi.com/2072-666X/14/5/1059info:eu-repo/semantics/altIdentifier/doi/10.3390/mi14051059info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:23:27Zoai:ri.conicet.gov.ar:11336/224976instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:23:27.982CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids |
title |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids |
spellingShingle |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids Venegas, Constanza J. CO2SNO4 ELECTROCHEMICAL DETECTION NANOHYBRIDS REDUCED GRAPHENE OXIDE |
title_short |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids |
title_full |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids |
title_fullStr |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids |
title_full_unstemmed |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids |
title_sort |
In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids |
dc.creator.none.fl_str_mv |
Venegas, Constanza J. Gutierrez, Fabiana Andrea Reeves McLaren, Nik Rivas, Gustavo Adolfo Ruiz León, Domingo Bollo, Soledad |
author |
Venegas, Constanza J. |
author_facet |
Venegas, Constanza J. Gutierrez, Fabiana Andrea Reeves McLaren, Nik Rivas, Gustavo Adolfo Ruiz León, Domingo Bollo, Soledad |
author_role |
author |
author2 |
Gutierrez, Fabiana Andrea Reeves McLaren, Nik Rivas, Gustavo Adolfo Ruiz León, Domingo Bollo, Soledad |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
CO2SNO4 ELECTROCHEMICAL DETECTION NANOHYBRIDS REDUCED GRAPHENE OXIDE |
topic |
CO2SNO4 ELECTROCHEMICAL DETECTION NANOHYBRIDS REDUCED GRAPHENE OXIDE |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
Nowadays, there is no doubt about the high electrocatalytic efficiency that is obtained when using hybrid materials between carbonaceous nanomaterials and transition metal oxides. However, the method to prepare them may involve differences in the observed analytical responses, making it necessary to evaluate them for each new material. The goal of this work was to obtain for the first time Co2SnO4 (CSO)/RGO nanohybrids via in situ and ex situ methods and to evaluate their performance in the amperometric detection of hydrogen peroxide. The electroanalytical response was evaluated in NaOH pH 12 solution using detection potentials of −0.400 V or 0.300 V for the reduction or oxidation of H2O2. The results show that for CSO there were no differences between the nanohybrids either by oxidation or by reduction, unlike what we previously observed with cobalt titanate hybrids, in which the in situ nanohybrid clearly had the best performance. On the other hand, no influence in the study of interferents and more stable signals were obtained when the reduction mode was used. In conclusion, for detecting hydrogen peroxide, any of the nanohybrids studied, i.e., in situ or ex situ, are suitable to be used, and more efficiency is obtained using the reduction mode. Fil: Venegas, Constanza J.. Universidad Tecnologica Metropolitana (utem); Fil: Gutierrez, Fabiana Andrea. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas. Laboratorio de Desarrollo Analítico y Quimiometría; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina Fil: Reeves McLaren, Nik. University Of Sheffield (university Of Sheffield); Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina Fil: Ruiz León, Domingo. Universidad de Santiago de Chile; Chile Fil: Bollo, Soledad. Universidad de Chile.; Chile |
description |
Nowadays, there is no doubt about the high electrocatalytic efficiency that is obtained when using hybrid materials between carbonaceous nanomaterials and transition metal oxides. However, the method to prepare them may involve differences in the observed analytical responses, making it necessary to evaluate them for each new material. The goal of this work was to obtain for the first time Co2SnO4 (CSO)/RGO nanohybrids via in situ and ex situ methods and to evaluate their performance in the amperometric detection of hydrogen peroxide. The electroanalytical response was evaluated in NaOH pH 12 solution using detection potentials of −0.400 V or 0.300 V for the reduction or oxidation of H2O2. The results show that for CSO there were no differences between the nanohybrids either by oxidation or by reduction, unlike what we previously observed with cobalt titanate hybrids, in which the in situ nanohybrid clearly had the best performance. On the other hand, no influence in the study of interferents and more stable signals were obtained when the reduction mode was used. In conclusion, for detecting hydrogen peroxide, any of the nanohybrids studied, i.e., in situ or ex situ, are suitable to be used, and more efficiency is obtained using the reduction mode. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-05 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/224976 Venegas, Constanza J.; Gutierrez, Fabiana Andrea; Reeves McLaren, Nik; Rivas, Gustavo Adolfo; Ruiz León, Domingo; et al.; In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids; MDPI; Micromachines; 14; 5; 5-2023; 1-11 2072-666X CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/224976 |
identifier_str_mv |
Venegas, Constanza J.; Gutierrez, Fabiana Andrea; Reeves McLaren, Nik; Rivas, Gustavo Adolfo; Ruiz León, Domingo; et al.; In situ or Ex situ Synthesis for Electrochemical Detection of Hydrogen Peroxide—An Evaluation of Co2SnO4/RGO Nanohybrids; MDPI; Micromachines; 14; 5; 5-2023; 1-11 2072-666X CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.mdpi.com/2072-666X/14/5/1059 info:eu-repo/semantics/altIdentifier/doi/10.3390/mi14051059 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
MDPI |
publisher.none.fl_str_mv |
MDPI |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844614229529722880 |
score |
13.070432 |