Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
- Autores
- Janeiro Tudanca, Ana Maria; Caraballo, Rolando Manuel; Herrera, Facundo Carlos; Giudici, Paula; Hamer, Mariana
- Año de publicación
- 2025
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring.
Fil: Janeiro Tudanca, Ana Maria. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina
Fil: Caraballo, Rolando Manuel. Universidad Nacional de Luján. Instituto de Ecología y Desarrollo Sustentable. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Ecología y Desarrollo Sustentable; Argentina
Fil: Herrera, Facundo Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energia Atomica. Gerencia de Area de Investigaciones y Aplicaciones No Nucleares (cac). Departamento Administracion del Proyecto Laboratorio Haces de Neutrones Ra-10 (cac).; Argentina
Fil: Giudici, Paula. Comisión Nacional de Energía Atómica. Gerencia del Área Investigaciones y Aplicaciones no Nucleares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Hamer, Mariana. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina - Materia
-
glyphosate
porphyrins
sensors
agrochemichals - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/270698
Ver los metadatos del registro completo
id |
CONICETDig_f0fda15281c78305e1ee13b3095aabec |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/270698 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samplesJaneiro Tudanca, Ana MariaCaraballo, Rolando ManuelHerrera, Facundo CarlosGiudici, PaulaHamer, Marianaglyphosateporphyrinssensorsagrochemichalshttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring.Fil: Janeiro Tudanca, Ana Maria. Universidad Nacional de General Sarmiento. Instituto de Ciencias; ArgentinaFil: Caraballo, Rolando Manuel. Universidad Nacional de Luján. Instituto de Ecología y Desarrollo Sustentable. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Ecología y Desarrollo Sustentable; ArgentinaFil: Herrera, Facundo Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energia Atomica. Gerencia de Area de Investigaciones y Aplicaciones No Nucleares (cac). Departamento Administracion del Proyecto Laboratorio Haces de Neutrones Ra-10 (cac).; ArgentinaFil: Giudici, Paula. Comisión Nacional de Energía Atómica. Gerencia del Área Investigaciones y Aplicaciones no Nucleares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Hamer, Mariana. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaRoyal Society of Chemistry2025-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/270698Janeiro Tudanca, Ana Maria; Caraballo, Rolando Manuel; Herrera, Facundo Carlos; Giudici, Paula; Hamer, Mariana; Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples; Royal Society of Chemistry; RSC Advances; 15; 37; 8-2025; 30482-304892046-2069CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://xlink.rsc.org/?DOI=D5RA05306Dinfo:eu-repo/semantics/altIdentifier/doi/10.1039/d5ra05306dinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:41:48Zoai:ri.conicet.gov.ar:11336/270698instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:41:49.168CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples |
title |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples |
spellingShingle |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples Janeiro Tudanca, Ana Maria glyphosate porphyrins sensors agrochemichals |
title_short |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples |
title_full |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples |
title_fullStr |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples |
title_full_unstemmed |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples |
title_sort |
Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples |
dc.creator.none.fl_str_mv |
Janeiro Tudanca, Ana Maria Caraballo, Rolando Manuel Herrera, Facundo Carlos Giudici, Paula Hamer, Mariana |
author |
Janeiro Tudanca, Ana Maria |
author_facet |
Janeiro Tudanca, Ana Maria Caraballo, Rolando Manuel Herrera, Facundo Carlos Giudici, Paula Hamer, Mariana |
author_role |
author |
author2 |
Caraballo, Rolando Manuel Herrera, Facundo Carlos Giudici, Paula Hamer, Mariana |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
glyphosate porphyrins sensors agrochemichals |
topic |
glyphosate porphyrins sensors agrochemichals |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring. Fil: Janeiro Tudanca, Ana Maria. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina Fil: Caraballo, Rolando Manuel. Universidad Nacional de Luján. Instituto de Ecología y Desarrollo Sustentable. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Ecología y Desarrollo Sustentable; Argentina Fil: Herrera, Facundo Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energia Atomica. Gerencia de Area de Investigaciones y Aplicaciones No Nucleares (cac). Departamento Administracion del Proyecto Laboratorio Haces de Neutrones Ra-10 (cac).; Argentina Fil: Giudici, Paula. Comisión Nacional de Energía Atómica. Gerencia del Área Investigaciones y Aplicaciones no Nucleares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Hamer, Mariana. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina |
description |
We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring. |
publishDate |
2025 |
dc.date.none.fl_str_mv |
2025-08 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/270698 Janeiro Tudanca, Ana Maria; Caraballo, Rolando Manuel; Herrera, Facundo Carlos; Giudici, Paula; Hamer, Mariana; Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples; Royal Society of Chemistry; RSC Advances; 15; 37; 8-2025; 30482-30489 2046-2069 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/270698 |
identifier_str_mv |
Janeiro Tudanca, Ana Maria; Caraballo, Rolando Manuel; Herrera, Facundo Carlos; Giudici, Paula; Hamer, Mariana; Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples; Royal Society of Chemistry; RSC Advances; 15; 37; 8-2025; 30482-30489 2046-2069 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://xlink.rsc.org/?DOI=D5RA05306D info:eu-repo/semantics/altIdentifier/doi/10.1039/d5ra05306d |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Royal Society of Chemistry |
publisher.none.fl_str_mv |
Royal Society of Chemistry |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613319232585728 |
score |
13.070432 |