We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring.
Fil: Janeiro Tudanca, Ana Maria. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina
Fil: Caraballo, Rolando Manuel. Universidad Nacional de Luján. Instituto de Ecología y Desarrollo Sustentable. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Ecología y Desarrollo Sustentable; Argentina
Fil: Herrera, Facundo Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energia Atomica. Gerencia de Area de Investigaciones y Aplicaciones No Nucleares (cac). Departamento Administracion del Proyecto Laboratorio Haces de Neutrones Ra-10 (cac).; Argentina
Fil: Giudici, Paula. Comisión Nacional de Energía Atómica. Gerencia del Área Investigaciones y Aplicaciones no Nucleares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Hamer, Mariana. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Materia
glyphosate
porphyrins
sensors
agrochemichals
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/270698

id CONICETDig_f0fda15281c78305e1ee13b3095aabec
oai_identifier_str oai:ri.conicet.gov.ar:11336/270698
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samplesJaneiro Tudanca, Ana MariaCaraballo, Rolando ManuelHerrera, Facundo CarlosGiudici, PaulaHamer, Marianaglyphosateporphyrinssensorsagrochemichalshttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring.Fil: Janeiro Tudanca, Ana Maria. Universidad Nacional de General Sarmiento. Instituto de Ciencias; ArgentinaFil: Caraballo, Rolando Manuel. Universidad Nacional de Luján. Instituto de Ecología y Desarrollo Sustentable. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Ecología y Desarrollo Sustentable; ArgentinaFil: Herrera, Facundo Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energia Atomica. Gerencia de Area de Investigaciones y Aplicaciones No Nucleares (cac). Departamento Administracion del Proyecto Laboratorio Haces de Neutrones Ra-10 (cac).; ArgentinaFil: Giudici, Paula. Comisión Nacional de Energía Atómica. Gerencia del Área Investigaciones y Aplicaciones no Nucleares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Hamer, Mariana. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaRoyal Society of Chemistry2025-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/270698Janeiro Tudanca, Ana Maria; Caraballo, Rolando Manuel; Herrera, Facundo Carlos; Giudici, Paula; Hamer, Mariana; Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples; Royal Society of Chemistry; RSC Advances; 15; 37; 8-2025; 30482-304892046-2069CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://xlink.rsc.org/?DOI=D5RA05306Dinfo:eu-repo/semantics/altIdentifier/doi/10.1039/d5ra05306dinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:41:48Zoai:ri.conicet.gov.ar:11336/270698instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:41:49.168CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
title Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
spellingShingle Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
Janeiro Tudanca, Ana Maria
glyphosate
porphyrins
sensors
agrochemichals
title_short Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
title_full Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
title_fullStr Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
title_full_unstemmed Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
title_sort Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples
dc.creator.none.fl_str_mv Janeiro Tudanca, Ana Maria
Caraballo, Rolando Manuel
Herrera, Facundo Carlos
Giudici, Paula
Hamer, Mariana
author Janeiro Tudanca, Ana Maria
author_facet Janeiro Tudanca, Ana Maria
Caraballo, Rolando Manuel
Herrera, Facundo Carlos
Giudici, Paula
Hamer, Mariana
author_role author
author2 Caraballo, Rolando Manuel
Herrera, Facundo Carlos
Giudici, Paula
Hamer, Mariana
author2_role author
author
author
author
dc.subject.none.fl_str_mv glyphosate
porphyrins
sensors
agrochemichals
topic glyphosate
porphyrins
sensors
agrochemichals
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring.
Fil: Janeiro Tudanca, Ana Maria. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina
Fil: Caraballo, Rolando Manuel. Universidad Nacional de Luján. Instituto de Ecología y Desarrollo Sustentable. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Ecología y Desarrollo Sustentable; Argentina
Fil: Herrera, Facundo Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comision Nacional de Energia Atomica. Gerencia de Area de Investigaciones y Aplicaciones No Nucleares (cac). Departamento Administracion del Proyecto Laboratorio Haces de Neutrones Ra-10 (cac).; Argentina
Fil: Giudici, Paula. Comisión Nacional de Energía Atómica. Gerencia del Área Investigaciones y Aplicaciones no Nucleares; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Hamer, Mariana. Universidad Nacional de General Sarmiento. Instituto de Ciencias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
description We present a biomimetic electrochemical sensor for glyphosate (GLY) detection, utilizing graphite electrodes modified with electropolymerized copper(II) meso-tetra(4-sulfonatophenyl)porphyrin (CuP). The Cu(II) centers provide dual functionality: catalytic oxygen reduction and selective GLY coordination, which leads to a proportional suppression of redox currents. Characterization (SEM-EDS/Raman/UV-Vis) confirmed CuP polymerization and specific GLY binding. The sensor achieved a 1 μmol L−1 detection limit (S/N = 3) with linear response (2–120 μmol L−1; RSD = 0.7%) and >98% recovery in spiked rainwater. Stability tests showed 99% signal retention after 30 days, outperforming enzyme-based sensors. This platform combines three key advantages: (1) sustainable fabrication ($0.12/electrode), (2) rapid analysis (<5 min per sample), and (3) field-deployability without instrumentation. The nanostructured CuP film improves sensitivity and contributes to selective GLY detection by excluding common interferents (nitrate/humic acid). Compared to chromatographic methods, this approach offers an eco-friendly alternative for environmental GLY monitoring.
publishDate 2025
dc.date.none.fl_str_mv 2025-08
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/270698
Janeiro Tudanca, Ana Maria; Caraballo, Rolando Manuel; Herrera, Facundo Carlos; Giudici, Paula; Hamer, Mariana; Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples; Royal Society of Chemistry; RSC Advances; 15; 37; 8-2025; 30482-30489
2046-2069
CONICET Digital
CONICET
url http://hdl.handle.net/11336/270698
identifier_str_mv Janeiro Tudanca, Ana Maria; Caraballo, Rolando Manuel; Herrera, Facundo Carlos; Giudici, Paula; Hamer, Mariana; Low-cost biomimetic sensor based on copper porphyrin-modified graphite electrodes for electrochemical detection of glyphosate in aqueous samples; Royal Society of Chemistry; RSC Advances; 15; 37; 8-2025; 30482-30489
2046-2069
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://xlink.rsc.org/?DOI=D5RA05306D
info:eu-repo/semantics/altIdentifier/doi/10.1039/d5ra05306d
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Royal Society of Chemistry
publisher.none.fl_str_mv Royal Society of Chemistry
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844613319232585728
score 13.070432