Nonlinear Dynamic Average Model of a DC-DC Converter
- Autores
- Busada, Claudio; Solsona, Jorge Alberto
- Año de publicación
- 2014
- Idioma
- español castellano
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A nonlinear dynamical average model of a dc-dc converter is presented. The converter under study has a particular feature. In this converter, classical average analysis cannot be applied because the ripple cannot be neglected in all state variables. For this reason, classical average analysis is not appropriated for obtaining an average model of the studied converter. In order to validate the introduced model, responses obtained by using the proposed average model and the commutated model are compared. The comparison is realized via simulation results.
Fil: Busada, Claudio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Bahía Blanca. Instituto de Investigación En Ingeniería Eléctrica; Argentina. Universidad Nacional del Sur. Departamento de Ingenieria Electrica y de Computadoras; Argentina
Fil: Solsona, Jorge Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Bahía Blanca. Instituto de Investigación En Ingeniería Eléctrica; Argentina. Universidad Nacional del Sur. Departamento de Ingenieria Electrica y de Computadoras; Argentina - Materia
-
Dc-Dc Converters
Average Model
Nonlinear Model
Power Conversion - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/11741
Ver los metadatos del registro completo
id |
CONICETDig_e0b7dad7943922eab10d1220438cdb3d |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/11741 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Nonlinear Dynamic Average Model of a DC-DC ConverterBusada, ClaudioSolsona, Jorge AlbertoDc-Dc ConvertersAverage ModelNonlinear ModelPower Conversionhttps://purl.org/becyt/ford/2.2https://purl.org/becyt/ford/2A nonlinear dynamical average model of a dc-dc converter is presented. The converter under study has a particular feature. In this converter, classical average analysis cannot be applied because the ripple cannot be neglected in all state variables. For this reason, classical average analysis is not appropriated for obtaining an average model of the studied converter. In order to validate the introduced model, responses obtained by using the proposed average model and the commutated model are compared. The comparison is realized via simulation results.Fil: Busada, Claudio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Bahía Blanca. Instituto de Investigación En Ingeniería Eléctrica; Argentina. Universidad Nacional del Sur. Departamento de Ingenieria Electrica y de Computadoras; ArgentinaFil: Solsona, Jorge Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Bahía Blanca. Instituto de Investigación En Ingeniería Eléctrica; Argentina. Universidad Nacional del Sur. Departamento de Ingenieria Electrica y de Computadoras; ArgentinaInstitute Of Electrical And Electronics Engineers2014-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/11741Busada, Claudio; Solsona, Jorge Alberto; Nonlinear Dynamic Average Model of a DC-DC Converter; Institute Of Electrical And Electronics Engineers; IEEE Latin America Transactions; 12; 5; 8-2014; 904-9091548-0992spainfo:eu-repo/semantics/altIdentifier/url/http://ieeexplore.ieee.org/document/6872904/info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:41:47Zoai:ri.conicet.gov.ar:11336/11741instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:41:47.99CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Nonlinear Dynamic Average Model of a DC-DC Converter |
title |
Nonlinear Dynamic Average Model of a DC-DC Converter |
spellingShingle |
Nonlinear Dynamic Average Model of a DC-DC Converter Busada, Claudio Dc-Dc Converters Average Model Nonlinear Model Power Conversion |
title_short |
Nonlinear Dynamic Average Model of a DC-DC Converter |
title_full |
Nonlinear Dynamic Average Model of a DC-DC Converter |
title_fullStr |
Nonlinear Dynamic Average Model of a DC-DC Converter |
title_full_unstemmed |
Nonlinear Dynamic Average Model of a DC-DC Converter |
title_sort |
Nonlinear Dynamic Average Model of a DC-DC Converter |
dc.creator.none.fl_str_mv |
Busada, Claudio Solsona, Jorge Alberto |
author |
Busada, Claudio |
author_facet |
Busada, Claudio Solsona, Jorge Alberto |
author_role |
author |
author2 |
Solsona, Jorge Alberto |
author2_role |
author |
dc.subject.none.fl_str_mv |
Dc-Dc Converters Average Model Nonlinear Model Power Conversion |
topic |
Dc-Dc Converters Average Model Nonlinear Model Power Conversion |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.2 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
A nonlinear dynamical average model of a dc-dc converter is presented. The converter under study has a particular feature. In this converter, classical average analysis cannot be applied because the ripple cannot be neglected in all state variables. For this reason, classical average analysis is not appropriated for obtaining an average model of the studied converter. In order to validate the introduced model, responses obtained by using the proposed average model and the commutated model are compared. The comparison is realized via simulation results. Fil: Busada, Claudio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Bahía Blanca. Instituto de Investigación En Ingeniería Eléctrica; Argentina. Universidad Nacional del Sur. Departamento de Ingenieria Electrica y de Computadoras; Argentina Fil: Solsona, Jorge Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Bahía Blanca. Instituto de Investigación En Ingeniería Eléctrica; Argentina. Universidad Nacional del Sur. Departamento de Ingenieria Electrica y de Computadoras; Argentina |
description |
A nonlinear dynamical average model of a dc-dc converter is presented. The converter under study has a particular feature. In this converter, classical average analysis cannot be applied because the ripple cannot be neglected in all state variables. For this reason, classical average analysis is not appropriated for obtaining an average model of the studied converter. In order to validate the introduced model, responses obtained by using the proposed average model and the commutated model are compared. The comparison is realized via simulation results. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-08 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/11741 Busada, Claudio; Solsona, Jorge Alberto; Nonlinear Dynamic Average Model of a DC-DC Converter; Institute Of Electrical And Electronics Engineers; IEEE Latin America Transactions; 12; 5; 8-2014; 904-909 1548-0992 |
url |
http://hdl.handle.net/11336/11741 |
identifier_str_mv |
Busada, Claudio; Solsona, Jorge Alberto; Nonlinear Dynamic Average Model of a DC-DC Converter; Institute Of Electrical And Electronics Engineers; IEEE Latin America Transactions; 12; 5; 8-2014; 904-909 1548-0992 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://ieeexplore.ieee.org/document/6872904/ |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Institute Of Electrical And Electronics Engineers |
publisher.none.fl_str_mv |
Institute Of Electrical And Electronics Engineers |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613318383239168 |
score |