Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications

Autores
Pereda, M. D.; Kang, Kyung Won; Bonetto, Rita Dominga; Llorente, Carlos Luis; Bilmes, Pablo David; Gervasi, Claudio
Año de publicación
2012
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
AISI 316 LVM stainless steel type considered in ASTM F138 and F139 standards for implant devices is widely used, in particular for orthopedic surgery, because it combines good biofunctionality and acceptable biocompatibility at low costs. Adequate interaction of these materials with the human body and its capability to reach the desired service level are determined by the surface preparation. The goal of the present work is to relate the surface roughness parameters with the localized corrosion resistance of AISI 316 LVM stainless steel grit blasted for different times and passivated with nitric acid. At intermediate blasting times the roughness parameters attain an extreme value and this surface condition corresponds with the maximum pitting corrosion resistance.
Fil: Pereda, M. D.. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Kang, Kyung Won. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Bonetto, Rita Dominga. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Ciencias Aplicadas "Dr. Jorge J. Ronco". Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Ciencias Aplicadas; Argentina
Fil: Llorente, Carlos Luis. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina
Fil: Bilmes, Pablo David. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Gervasi, Claudio. Universidad Nacional de La Plata. Facultad de Ingenierí­a. Departamento de Ingeniería Química; Argentina
Materia
316 Lvm Stainless Steel
Glass Beads Blasting
Roughness Parameters
Corrosion
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/77888

id CONICETDig_d6b918a2a8fd8521d9af1b8f595726bd
oai_identifier_str oai:ri.conicet.gov.ar:11336/77888
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applicationsPereda, M. D.Kang, Kyung WonBonetto, Rita DomingaLlorente, Carlos LuisBilmes, Pablo DavidGervasi, Claudio316 Lvm Stainless SteelGlass Beads BlastingRoughness ParametersCorrosionAISI 316 LVM stainless steel type considered in ASTM F138 and F139 standards for implant devices is widely used, in particular for orthopedic surgery, because it combines good biofunctionality and acceptable biocompatibility at low costs. Adequate interaction of these materials with the human body and its capability to reach the desired service level are determined by the surface preparation. The goal of the present work is to relate the surface roughness parameters with the localized corrosion resistance of AISI 316 LVM stainless steel grit blasted for different times and passivated with nitric acid. At intermediate blasting times the roughness parameters attain an extreme value and this surface condition corresponds with the maximum pitting corrosion resistance.Fil: Pereda, M. D.. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; ArgentinaFil: Kang, Kyung Won. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; ArgentinaFil: Bonetto, Rita Dominga. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Ciencias Aplicadas "Dr. Jorge J. Ronco". Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Ciencias Aplicadas; ArgentinaFil: Llorente, Carlos Luis. Universidad Nacional de La Plata. Facultad de Ingeniería; ArgentinaFil: Bilmes, Pablo David. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Gervasi, Claudio. Universidad Nacional de La Plata. Facultad de Ingenierí­a. Departamento de Ingeniería Química; ArgentinaElsevier2012-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/77888Pereda, M. D.; Kang, Kyung Won; Bonetto, Rita Dominga; Llorente, Carlos Luis; Bilmes, Pablo David; et al.; Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications; Elsevier; Procedia Materials Science; 1; 6-2012; 446-4532211-8128CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.mspro.2012.06.060info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S2211812812000612info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:29:18Zoai:ri.conicet.gov.ar:11336/77888instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:29:19.092CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
title Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
spellingShingle Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
Pereda, M. D.
316 Lvm Stainless Steel
Glass Beads Blasting
Roughness Parameters
Corrosion
title_short Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
title_full Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
title_fullStr Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
title_full_unstemmed Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
title_sort Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
dc.creator.none.fl_str_mv Pereda, M. D.
Kang, Kyung Won
Bonetto, Rita Dominga
Llorente, Carlos Luis
Bilmes, Pablo David
Gervasi, Claudio
author Pereda, M. D.
author_facet Pereda, M. D.
Kang, Kyung Won
Bonetto, Rita Dominga
Llorente, Carlos Luis
Bilmes, Pablo David
Gervasi, Claudio
author_role author
author2 Kang, Kyung Won
Bonetto, Rita Dominga
Llorente, Carlos Luis
Bilmes, Pablo David
Gervasi, Claudio
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv 316 Lvm Stainless Steel
Glass Beads Blasting
Roughness Parameters
Corrosion
topic 316 Lvm Stainless Steel
Glass Beads Blasting
Roughness Parameters
Corrosion
dc.description.none.fl_txt_mv AISI 316 LVM stainless steel type considered in ASTM F138 and F139 standards for implant devices is widely used, in particular for orthopedic surgery, because it combines good biofunctionality and acceptable biocompatibility at low costs. Adequate interaction of these materials with the human body and its capability to reach the desired service level are determined by the surface preparation. The goal of the present work is to relate the surface roughness parameters with the localized corrosion resistance of AISI 316 LVM stainless steel grit blasted for different times and passivated with nitric acid. At intermediate blasting times the roughness parameters attain an extreme value and this surface condition corresponds with the maximum pitting corrosion resistance.
Fil: Pereda, M. D.. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Kang, Kyung Won. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Bonetto, Rita Dominga. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Ciencias Aplicadas "Dr. Jorge J. Ronco". Universidad Nacional de la Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Ciencias Aplicadas; Argentina
Fil: Llorente, Carlos Luis. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina
Fil: Bilmes, Pablo David. Universidad Nacional de La Plata. Facultad de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Gervasi, Claudio. Universidad Nacional de La Plata. Facultad de Ingenierí­a. Departamento de Ingeniería Química; Argentina
description AISI 316 LVM stainless steel type considered in ASTM F138 and F139 standards for implant devices is widely used, in particular for orthopedic surgery, because it combines good biofunctionality and acceptable biocompatibility at low costs. Adequate interaction of these materials with the human body and its capability to reach the desired service level are determined by the surface preparation. The goal of the present work is to relate the surface roughness parameters with the localized corrosion resistance of AISI 316 LVM stainless steel grit blasted for different times and passivated with nitric acid. At intermediate blasting times the roughness parameters attain an extreme value and this surface condition corresponds with the maximum pitting corrosion resistance.
publishDate 2012
dc.date.none.fl_str_mv 2012-06
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/77888
Pereda, M. D.; Kang, Kyung Won; Bonetto, Rita Dominga; Llorente, Carlos Luis; Bilmes, Pablo David; et al.; Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications; Elsevier; Procedia Materials Science; 1; 6-2012; 446-453
2211-8128
CONICET Digital
CONICET
url http://hdl.handle.net/11336/77888
identifier_str_mv Pereda, M. D.; Kang, Kyung Won; Bonetto, Rita Dominga; Llorente, Carlos Luis; Bilmes, Pablo David; et al.; Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications; Elsevier; Procedia Materials Science; 1; 6-2012; 446-453
2211-8128
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1016/j.mspro.2012.06.060
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S2211812812000612
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614298775584768
score 13.070432