Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process

Autores
Ramos, Pamela Belen; Vitale, Paula; Barreto, Gastón Pablo; Aparicio, Francisca; Dublan, María de Los Ángeles; Eyler, Gladys Nora
Año de publicación
2020
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Textile industries present notable environmental problems related mainly to the use and management of water resources. The application of advanced oxidation technologies (AOT) to a real and complex system was analyzed. The degradation of a real textile effluent in the presence of commercial steel wool (CSW, zero-valent iron) and H2O2 as oxidant was studied. The effects of H2O2 concentration (0-0.08 mol L-1), mass of CSW (0-0.4 g L-1) and temperature (15-45 °C) on the reduction of the chemical oxygen demand (COD) of the textile effluent were evaluated. Kinetic studies were performed at laboratory and pilot scales at different temperatures under optimal conditions (0.037 mol L-1 of H2O2 and 0.247 g L-1 of CSW). Iron species (Fe2+, Fe3+, total Fe) were quantified in solution for different experiments as a function of time. COD reductions of 87.69% at lab scale and 89.55% at optimized pilot scale in 300 min (140.66 mgO2 L-1 of COD, final discharge) were obtained. A metallurgical residue was tested as iron source, obtaining high COD removal (65%). Operating costs were calculated. Phytotoxicity tests performed before and after treatment showed that the effluent treated under optimal conditions was non-toxic.
Fil: Ramos, Pamela Belen. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Vitale, Paula. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Investigaciones Arqueológicas y Paleontológicas del Cuaternario Pampeano. Universidad Nacional del Centro de la Provincia de Buenos Aires. Investigaciones Arqueológicas y Paleontológicas del Cuaternario Pampeano; Argentina
Fil: Barreto, Gastón Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Aparicio, Francisca. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Dublan, María de Los Ángeles. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Agronomía. Centro Regional de Estudios Sistémico de Cadenas Agroalimentarias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Eyler, Gladys Nora. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Materia
ADVANCED OXIDATION TECHNOLOGIES (AOT)
DEGRADATION
PHYTOTOXICITY TESTS
WASTEWATER
ZERO-VALENT IRON
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/137963

id CONICETDig_b4d18163bb2fe64f1fad2b6190cf46dd
oai_identifier_str oai:ri.conicet.gov.ar:11336/137963
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2processRamos, Pamela BelenVitale, PaulaBarreto, Gastón PabloAparicio, FranciscaDublan, María de Los ÁngelesEyler, Gladys NoraADVANCED OXIDATION TECHNOLOGIES (AOT)DEGRADATIONPHYTOTOXICITY TESTSWASTEWATERZERO-VALENT IRONhttps://purl.org/becyt/ford/2.4https://purl.org/becyt/ford/2https://purl.org/becyt/ford/2.7https://purl.org/becyt/ford/2Textile industries present notable environmental problems related mainly to the use and management of water resources. The application of advanced oxidation technologies (AOT) to a real and complex system was analyzed. The degradation of a real textile effluent in the presence of commercial steel wool (CSW, zero-valent iron) and H2O2 as oxidant was studied. The effects of H2O2 concentration (0-0.08 mol L-1), mass of CSW (0-0.4 g L-1) and temperature (15-45 °C) on the reduction of the chemical oxygen demand (COD) of the textile effluent were evaluated. Kinetic studies were performed at laboratory and pilot scales at different temperatures under optimal conditions (0.037 mol L-1 of H2O2 and 0.247 g L-1 of CSW). Iron species (Fe2+, Fe3+, total Fe) were quantified in solution for different experiments as a function of time. COD reductions of 87.69% at lab scale and 89.55% at optimized pilot scale in 300 min (140.66 mgO2 L-1 of COD, final discharge) were obtained. A metallurgical residue was tested as iron source, obtaining high COD removal (65%). Operating costs were calculated. Phytotoxicity tests performed before and after treatment showed that the effluent treated under optimal conditions was non-toxic.Fil: Ramos, Pamela Belen. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Vitale, Paula. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Investigaciones Arqueológicas y Paleontológicas del Cuaternario Pampeano. Universidad Nacional del Centro de la Provincia de Buenos Aires. Investigaciones Arqueológicas y Paleontológicas del Cuaternario Pampeano; ArgentinaFil: Barreto, Gastón Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Aparicio, Francisca. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; ArgentinaFil: Dublan, María de Los Ángeles. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Agronomía. Centro Regional de Estudios Sistémico de Cadenas Agroalimentarias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Eyler, Gladys Nora. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaElsevier2020-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/137963Ramos, Pamela Belen; Vitale, Paula; Barreto, Gastón Pablo; Aparicio, Francisca; Dublan, María de Los Ángeles; et al.; Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process; Elsevier; Journal of Environmental Chemical Engineering; 8; 4; 8-2020; 1-402213-3437CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S221334372030302Xinfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.jece.2020.103954info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-11-12T09:34:28Zoai:ri.conicet.gov.ar:11336/137963instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-11-12 09:34:28.661CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
title Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
spellingShingle Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
Ramos, Pamela Belen
ADVANCED OXIDATION TECHNOLOGIES (AOT)
DEGRADATION
PHYTOTOXICITY TESTS
WASTEWATER
ZERO-VALENT IRON
title_short Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
title_full Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
title_fullStr Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
title_full_unstemmed Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
title_sort Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process
dc.creator.none.fl_str_mv Ramos, Pamela Belen
Vitale, Paula
Barreto, Gastón Pablo
Aparicio, Francisca
Dublan, María de Los Ángeles
Eyler, Gladys Nora
author Ramos, Pamela Belen
author_facet Ramos, Pamela Belen
Vitale, Paula
Barreto, Gastón Pablo
Aparicio, Francisca
Dublan, María de Los Ángeles
Eyler, Gladys Nora
author_role author
author2 Vitale, Paula
Barreto, Gastón Pablo
Aparicio, Francisca
Dublan, María de Los Ángeles
Eyler, Gladys Nora
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv ADVANCED OXIDATION TECHNOLOGIES (AOT)
DEGRADATION
PHYTOTOXICITY TESTS
WASTEWATER
ZERO-VALENT IRON
topic ADVANCED OXIDATION TECHNOLOGIES (AOT)
DEGRADATION
PHYTOTOXICITY TESTS
WASTEWATER
ZERO-VALENT IRON
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.4
https://purl.org/becyt/ford/2
https://purl.org/becyt/ford/2.7
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv Textile industries present notable environmental problems related mainly to the use and management of water resources. The application of advanced oxidation technologies (AOT) to a real and complex system was analyzed. The degradation of a real textile effluent in the presence of commercial steel wool (CSW, zero-valent iron) and H2O2 as oxidant was studied. The effects of H2O2 concentration (0-0.08 mol L-1), mass of CSW (0-0.4 g L-1) and temperature (15-45 °C) on the reduction of the chemical oxygen demand (COD) of the textile effluent were evaluated. Kinetic studies were performed at laboratory and pilot scales at different temperatures under optimal conditions (0.037 mol L-1 of H2O2 and 0.247 g L-1 of CSW). Iron species (Fe2+, Fe3+, total Fe) were quantified in solution for different experiments as a function of time. COD reductions of 87.69% at lab scale and 89.55% at optimized pilot scale in 300 min (140.66 mgO2 L-1 of COD, final discharge) were obtained. A metallurgical residue was tested as iron source, obtaining high COD removal (65%). Operating costs were calculated. Phytotoxicity tests performed before and after treatment showed that the effluent treated under optimal conditions was non-toxic.
Fil: Ramos, Pamela Belen. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Vitale, Paula. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Investigaciones Arqueológicas y Paleontológicas del Cuaternario Pampeano. Universidad Nacional del Centro de la Provincia de Buenos Aires. Investigaciones Arqueológicas y Paleontológicas del Cuaternario Pampeano; Argentina
Fil: Barreto, Gastón Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Aparicio, Francisca. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Dublan, María de Los Ángeles. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Agronomía. Centro Regional de Estudios Sistémico de Cadenas Agroalimentarias; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Eyler, Gladys Nora. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires. - Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
description Textile industries present notable environmental problems related mainly to the use and management of water resources. The application of advanced oxidation technologies (AOT) to a real and complex system was analyzed. The degradation of a real textile effluent in the presence of commercial steel wool (CSW, zero-valent iron) and H2O2 as oxidant was studied. The effects of H2O2 concentration (0-0.08 mol L-1), mass of CSW (0-0.4 g L-1) and temperature (15-45 °C) on the reduction of the chemical oxygen demand (COD) of the textile effluent were evaluated. Kinetic studies were performed at laboratory and pilot scales at different temperatures under optimal conditions (0.037 mol L-1 of H2O2 and 0.247 g L-1 of CSW). Iron species (Fe2+, Fe3+, total Fe) were quantified in solution for different experiments as a function of time. COD reductions of 87.69% at lab scale and 89.55% at optimized pilot scale in 300 min (140.66 mgO2 L-1 of COD, final discharge) were obtained. A metallurgical residue was tested as iron source, obtaining high COD removal (65%). Operating costs were calculated. Phytotoxicity tests performed before and after treatment showed that the effluent treated under optimal conditions was non-toxic.
publishDate 2020
dc.date.none.fl_str_mv 2020-08
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/137963
Ramos, Pamela Belen; Vitale, Paula; Barreto, Gastón Pablo; Aparicio, Francisca; Dublan, María de Los Ángeles; et al.; Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process; Elsevier; Journal of Environmental Chemical Engineering; 8; 4; 8-2020; 1-40
2213-3437
CONICET Digital
CONICET
url http://hdl.handle.net/11336/137963
identifier_str_mv Ramos, Pamela Belen; Vitale, Paula; Barreto, Gastón Pablo; Aparicio, Francisca; Dublan, María de Los Ángeles; et al.; Treatment of real non-biodegradable wastewater: Feasibility analysis of a zero-valent iron/H2O2process; Elsevier; Journal of Environmental Chemical Engineering; 8; 4; 8-2020; 1-40
2213-3437
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S221334372030302X
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jece.2020.103954
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1848597126936788992
score 12.976206