Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles

Autores
Alustiza, Diego Horacio; Mineo, Marcos; Arce, Valeria Beatriz; Villa Perez, Cristian; Russo, Nelida Araceli
Año de publicación
2023
Idioma
español castellano
Tipo de recurso
artículo
Estado
versión publicada
Descripción
This paper presents the results obtained in the execution of the first steps of the functional evaluation process of a fiber optic relative humidity sensor. The sensor device was a long period fiber grating (LPG) whose manufacturing process is described. Information is provided on how a humidity sensitivity level was reached that allows relative humidity (RH) measurements to be made. Packaging design implemented is described. Experimental arrangements used for thermal characterization and for humidity response are described. The results are discussed highlighting the details of the experimental setup to be improved in the future. Finally, the conclusions that qualify the feasibility of the implementation of an embedded humidity sensor in concrete structures by using this type of technology are provided.
En este trabajo se presentan los resultados obtenidos en la ejecución de los primeros pasos del proceso de evaluación funcional de un sensor de humedad relativa implementado en fibra óptica. El dispositivo sensor fue una red de período largo (LPG) cuyo proceso de fabricación es descripto. Se brinda información de cómo se alcanzó un nivel de sensibilidad a la humedad que permita realizar mediciones de humedad relativa (HR). Se describe el diseño del encapsulado implementado. Se finaliza describiendo los arreglos experimentales usados para la caracterización térmica y la determinación del comportamiento del sensor ante un barrido en humedad. Se discuten los resultados resaltando los detalles del arreglo experimental a ser mejorados. Finalmente se brindan las conclusiones que califican la factibilidad de la implementación de un sensor de humedad potencialmente embebible dentro de estructuras de hormigón utilizando este tipo de tecnología.
Fil: Alustiza, Diego Horacio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina. Universidad Tecnológica Nacional; Argentina
Fil: Mineo, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
Fil: Arce, Valeria Beatriz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
Fil: Villa Perez, Cristian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
Fil: Russo, Nelida Araceli. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
Materia
LONG PERIOD FIBER GRATING
OPTICAL FIBER SENSOR
RELATIVE HUMIDITY SENSOR
STRUCTURAL HEALTH MONITORING
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/227226

id CONICETDig_96d8be6ae84ffb5359c8dc4c80fa1a3e
oai_identifier_str oai:ri.conicet.gov.ar:11336/227226
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civilesExperimental fiber optic humidity sensor with applicability to civil structures health monitoringAlustiza, Diego HoracioMineo, MarcosArce, Valeria BeatrizVilla Perez, CristianRusso, Nelida AraceliLONG PERIOD FIBER GRATINGOPTICAL FIBER SENSORRELATIVE HUMIDITY SENSORSTRUCTURAL HEALTH MONITORINGhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1This paper presents the results obtained in the execution of the first steps of the functional evaluation process of a fiber optic relative humidity sensor. The sensor device was a long period fiber grating (LPG) whose manufacturing process is described. Information is provided on how a humidity sensitivity level was reached that allows relative humidity (RH) measurements to be made. Packaging design implemented is described. Experimental arrangements used for thermal characterization and for humidity response are described. The results are discussed highlighting the details of the experimental setup to be improved in the future. Finally, the conclusions that qualify the feasibility of the implementation of an embedded humidity sensor in concrete structures by using this type of technology are provided.En este trabajo se presentan los resultados obtenidos en la ejecución de los primeros pasos del proceso de evaluación funcional de un sensor de humedad relativa implementado en fibra óptica. El dispositivo sensor fue una red de período largo (LPG) cuyo proceso de fabricación es descripto. Se brinda información de cómo se alcanzó un nivel de sensibilidad a la humedad que permita realizar mediciones de humedad relativa (HR). Se describe el diseño del encapsulado implementado. Se finaliza describiendo los arreglos experimentales usados para la caracterización térmica y la determinación del comportamiento del sensor ante un barrido en humedad. Se discuten los resultados resaltando los detalles del arreglo experimental a ser mejorados. Finalmente se brindan las conclusiones que califican la factibilidad de la implementación de un sensor de humedad potencialmente embebible dentro de estructuras de hormigón utilizando este tipo de tecnología.Fil: Alustiza, Diego Horacio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina. Universidad Tecnológica Nacional; ArgentinaFil: Mineo, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; ArgentinaFil: Arce, Valeria Beatriz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; ArgentinaFil: Villa Perez, Cristian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; ArgentinaFil: Russo, Nelida Araceli. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; ArgentinaSociedad Española de Óptica2023-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/227226Alustiza, Diego Horacio; Mineo, Marcos; Arce, Valeria Beatriz; Villa Perez, Cristian; Russo, Nelida Araceli; Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles; Sociedad Española de Óptica; Optica Pura y Aplicada; 56; 2; 6-2023; 1-170030-39172171-8814CONICET DigitalCONICETspainfo:eu-repo/semantics/altIdentifier/url/http://opa.sedoptica.es/es/articulo/1991info:eu-repo/semantics/altIdentifier/doi/10.7149/OPA.56.2.51138info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:10:35Zoai:ri.conicet.gov.ar:11336/227226instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:10:35.887CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
Experimental fiber optic humidity sensor with applicability to civil structures health monitoring
title Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
spellingShingle Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
Alustiza, Diego Horacio
LONG PERIOD FIBER GRATING
OPTICAL FIBER SENSOR
RELATIVE HUMIDITY SENSOR
STRUCTURAL HEALTH MONITORING
title_short Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
title_full Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
title_fullStr Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
title_full_unstemmed Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
title_sort Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles
dc.creator.none.fl_str_mv Alustiza, Diego Horacio
Mineo, Marcos
Arce, Valeria Beatriz
Villa Perez, Cristian
Russo, Nelida Araceli
author Alustiza, Diego Horacio
author_facet Alustiza, Diego Horacio
Mineo, Marcos
Arce, Valeria Beatriz
Villa Perez, Cristian
Russo, Nelida Araceli
author_role author
author2 Mineo, Marcos
Arce, Valeria Beatriz
Villa Perez, Cristian
Russo, Nelida Araceli
author2_role author
author
author
author
dc.subject.none.fl_str_mv LONG PERIOD FIBER GRATING
OPTICAL FIBER SENSOR
RELATIVE HUMIDITY SENSOR
STRUCTURAL HEALTH MONITORING
topic LONG PERIOD FIBER GRATING
OPTICAL FIBER SENSOR
RELATIVE HUMIDITY SENSOR
STRUCTURAL HEALTH MONITORING
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv This paper presents the results obtained in the execution of the first steps of the functional evaluation process of a fiber optic relative humidity sensor. The sensor device was a long period fiber grating (LPG) whose manufacturing process is described. Information is provided on how a humidity sensitivity level was reached that allows relative humidity (RH) measurements to be made. Packaging design implemented is described. Experimental arrangements used for thermal characterization and for humidity response are described. The results are discussed highlighting the details of the experimental setup to be improved in the future. Finally, the conclusions that qualify the feasibility of the implementation of an embedded humidity sensor in concrete structures by using this type of technology are provided.
En este trabajo se presentan los resultados obtenidos en la ejecución de los primeros pasos del proceso de evaluación funcional de un sensor de humedad relativa implementado en fibra óptica. El dispositivo sensor fue una red de período largo (LPG) cuyo proceso de fabricación es descripto. Se brinda información de cómo se alcanzó un nivel de sensibilidad a la humedad que permita realizar mediciones de humedad relativa (HR). Se describe el diseño del encapsulado implementado. Se finaliza describiendo los arreglos experimentales usados para la caracterización térmica y la determinación del comportamiento del sensor ante un barrido en humedad. Se discuten los resultados resaltando los detalles del arreglo experimental a ser mejorados. Finalmente se brindan las conclusiones que califican la factibilidad de la implementación de un sensor de humedad potencialmente embebible dentro de estructuras de hormigón utilizando este tipo de tecnología.
Fil: Alustiza, Diego Horacio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina. Universidad Tecnológica Nacional; Argentina
Fil: Mineo, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
Fil: Arce, Valeria Beatriz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
Fil: Villa Perez, Cristian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
Fil: Russo, Nelida Araceli. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigaciones Ópticas. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigaciones Ópticas. Universidad Nacional de La Plata. Centro de Investigaciones Ópticas; Argentina
description This paper presents the results obtained in the execution of the first steps of the functional evaluation process of a fiber optic relative humidity sensor. The sensor device was a long period fiber grating (LPG) whose manufacturing process is described. Information is provided on how a humidity sensitivity level was reached that allows relative humidity (RH) measurements to be made. Packaging design implemented is described. Experimental arrangements used for thermal characterization and for humidity response are described. The results are discussed highlighting the details of the experimental setup to be improved in the future. Finally, the conclusions that qualify the feasibility of the implementation of an embedded humidity sensor in concrete structures by using this type of technology are provided.
publishDate 2023
dc.date.none.fl_str_mv 2023-06
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/227226
Alustiza, Diego Horacio; Mineo, Marcos; Arce, Valeria Beatriz; Villa Perez, Cristian; Russo, Nelida Araceli; Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles; Sociedad Española de Óptica; Optica Pura y Aplicada; 56; 2; 6-2023; 1-17
0030-3917
2171-8814
CONICET Digital
CONICET
url http://hdl.handle.net/11336/227226
identifier_str_mv Alustiza, Diego Horacio; Mineo, Marcos; Arce, Valeria Beatriz; Villa Perez, Cristian; Russo, Nelida Araceli; Sensor experimental de fibra óptica con aplicabilidad al monitoreo de salud de estructuras civiles; Sociedad Española de Óptica; Optica Pura y Aplicada; 56; 2; 6-2023; 1-17
0030-3917
2171-8814
CONICET Digital
CONICET
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://opa.sedoptica.es/es/articulo/1991
info:eu-repo/semantics/altIdentifier/doi/10.7149/OPA.56.2.51138
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Sociedad Española de Óptica
publisher.none.fl_str_mv Sociedad Española de Óptica
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844613996858048512
score 13.070432