Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device
- Autores
- Skladnik-Sadowska, E.; Baranowski, J.; Milanese, Maria Magdalena; Moroso, Roberto Luis; Pouzo, Jorge Osvaldo; Sadowski, M.; Zebrowski, J.
- Año de publicación
- 2001
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- The paper reports the application of Solid-State Nuclear Track Detectors to study the pulsed plasma-ion streams emitted from plasma-focus (PF) type discharges, which were performed within a low-energy PACO device constructed at Instituto de Fisica Arroyo Seco. The PACO device was operated under static initial gas conditions or with dynamic gas puffing. Studies of the structure of the fast deuteron beams were carried out within an energy range from 80 keV to about 2 MeV. Studies of ion energy and an ion angular distribution were also performed. The measurements showed that the fast deuterons are emitted in many "narrow" micro-beams, as in other larger PF devices. The anisotropy of the deuteron angular distribution was explained by the stochastic character of the formation of local ion sources within the PF discharge column.
Fil: Skladnik-Sadowska, E.. No especifíca;
Fil: Baranowski, J.. No especifíca;
Fil: Milanese, Maria Magdalena. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Moroso, Roberto Luis. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Pouzo, Jorge Osvaldo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Sadowski, M.. No especifíca;
Fil: Zebrowski, J.. No especifíca; - Materia
-
ION PINHOLE CAMERA
PLASMA FOCUS
PLASMA-ION STREAM
SOLID-STATE NUCLEAR TRACK DETECTOR - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/128620
Ver los metadatos del registro completo
id |
CONICETDig_8e61572a7ffa818e0feff495c7d2dbe5 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/128620 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF deviceSkladnik-Sadowska, E.Baranowski, J.Milanese, Maria MagdalenaMoroso, Roberto LuisPouzo, Jorge OsvaldoSadowski, M.Zebrowski, J.ION PINHOLE CAMERAPLASMA FOCUSPLASMA-ION STREAMSOLID-STATE NUCLEAR TRACK DETECTORhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1The paper reports the application of Solid-State Nuclear Track Detectors to study the pulsed plasma-ion streams emitted from plasma-focus (PF) type discharges, which were performed within a low-energy PACO device constructed at Instituto de Fisica Arroyo Seco. The PACO device was operated under static initial gas conditions or with dynamic gas puffing. Studies of the structure of the fast deuteron beams were carried out within an energy range from 80 keV to about 2 MeV. Studies of ion energy and an ion angular distribution were also performed. The measurements showed that the fast deuterons are emitted in many "narrow" micro-beams, as in other larger PF devices. The anisotropy of the deuteron angular distribution was explained by the stochastic character of the formation of local ion sources within the PF discharge column.Fil: Skladnik-Sadowska, E.. No especifíca;Fil: Baranowski, J.. No especifíca;Fil: Milanese, Maria Magdalena. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Moroso, Roberto Luis. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Pouzo, Jorge Osvaldo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Sadowski, M.. No especifíca;Fil: Zebrowski, J.. No especifíca;Pergamon-Elsevier Science Ltd2001-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/128620Skladnik-Sadowska, E.; Baranowski, J.; Milanese, Maria Magdalena; Moroso, Roberto Luis; Pouzo, Jorge Osvaldo; et al.; Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device; Pergamon-Elsevier Science Ltd; Radiation Measurements; 34; 1-6; 6-2001; 315-3181350-4487CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S1350448701001755info:eu-repo/semantics/altIdentifier/doi/10.1016/S1350-4487(01)00175-5info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T14:29:03Zoai:ri.conicet.gov.ar:11336/128620instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 14:29:03.513CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device |
title |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device |
spellingShingle |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device Skladnik-Sadowska, E. ION PINHOLE CAMERA PLASMA FOCUS PLASMA-ION STREAM SOLID-STATE NUCLEAR TRACK DETECTOR |
title_short |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device |
title_full |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device |
title_fullStr |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device |
title_full_unstemmed |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device |
title_sort |
Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device |
dc.creator.none.fl_str_mv |
Skladnik-Sadowska, E. Baranowski, J. Milanese, Maria Magdalena Moroso, Roberto Luis Pouzo, Jorge Osvaldo Sadowski, M. Zebrowski, J. |
author |
Skladnik-Sadowska, E. |
author_facet |
Skladnik-Sadowska, E. Baranowski, J. Milanese, Maria Magdalena Moroso, Roberto Luis Pouzo, Jorge Osvaldo Sadowski, M. Zebrowski, J. |
author_role |
author |
author2 |
Baranowski, J. Milanese, Maria Magdalena Moroso, Roberto Luis Pouzo, Jorge Osvaldo Sadowski, M. Zebrowski, J. |
author2_role |
author author author author author author |
dc.subject.none.fl_str_mv |
ION PINHOLE CAMERA PLASMA FOCUS PLASMA-ION STREAM SOLID-STATE NUCLEAR TRACK DETECTOR |
topic |
ION PINHOLE CAMERA PLASMA FOCUS PLASMA-ION STREAM SOLID-STATE NUCLEAR TRACK DETECTOR |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
The paper reports the application of Solid-State Nuclear Track Detectors to study the pulsed plasma-ion streams emitted from plasma-focus (PF) type discharges, which were performed within a low-energy PACO device constructed at Instituto de Fisica Arroyo Seco. The PACO device was operated under static initial gas conditions or with dynamic gas puffing. Studies of the structure of the fast deuteron beams were carried out within an energy range from 80 keV to about 2 MeV. Studies of ion energy and an ion angular distribution were also performed. The measurements showed that the fast deuterons are emitted in many "narrow" micro-beams, as in other larger PF devices. The anisotropy of the deuteron angular distribution was explained by the stochastic character of the formation of local ion sources within the PF discharge column. Fil: Skladnik-Sadowska, E.. No especifíca; Fil: Baranowski, J.. No especifíca; Fil: Milanese, Maria Magdalena. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina Fil: Moroso, Roberto Luis. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina Fil: Pouzo, Jorge Osvaldo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Física Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina Fil: Sadowski, M.. No especifíca; Fil: Zebrowski, J.. No especifíca; |
description |
The paper reports the application of Solid-State Nuclear Track Detectors to study the pulsed plasma-ion streams emitted from plasma-focus (PF) type discharges, which were performed within a low-energy PACO device constructed at Instituto de Fisica Arroyo Seco. The PACO device was operated under static initial gas conditions or with dynamic gas puffing. Studies of the structure of the fast deuteron beams were carried out within an energy range from 80 keV to about 2 MeV. Studies of ion energy and an ion angular distribution were also performed. The measurements showed that the fast deuterons are emitted in many "narrow" micro-beams, as in other larger PF devices. The anisotropy of the deuteron angular distribution was explained by the stochastic character of the formation of local ion sources within the PF discharge column. |
publishDate |
2001 |
dc.date.none.fl_str_mv |
2001-06 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/128620 Skladnik-Sadowska, E.; Baranowski, J.; Milanese, Maria Magdalena; Moroso, Roberto Luis; Pouzo, Jorge Osvaldo; et al.; Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device; Pergamon-Elsevier Science Ltd; Radiation Measurements; 34; 1-6; 6-2001; 315-318 1350-4487 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/128620 |
identifier_str_mv |
Skladnik-Sadowska, E.; Baranowski, J.; Milanese, Maria Magdalena; Moroso, Roberto Luis; Pouzo, Jorge Osvaldo; et al.; Spatial structure and energy spectrum of ion beams studied with CN detectors within a small PF device; Pergamon-Elsevier Science Ltd; Radiation Measurements; 34; 1-6; 6-2001; 315-318 1350-4487 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S1350448701001755 info:eu-repo/semantics/altIdentifier/doi/10.1016/S1350-4487(01)00175-5 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Pergamon-Elsevier Science Ltd |
publisher.none.fl_str_mv |
Pergamon-Elsevier Science Ltd |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1846082758721404928 |
score |
13.22299 |