Simplified sleep resistance test for daytime sleepiness detection

Autores
Larrateguy, Luis Darío; Pais, Carlos Marcelo; Larrateguy, Luis Ignacio; Larrateguy, Santiago Darío; Schlotthauer, Gaston
Año de publicación
2020
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Objectives: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. Material and Methods: In the new test, during 20 minute subjects were asked to pass a finger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. Results: The proposed method showed a sensitivity of 100% and a specificity of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the confidence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). Conclusion: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel.
Fil: Larrateguy, Luis Darío. Centro Privado de Medicina Respiratoria; Argentina
Fil: Pais, Carlos Marcelo. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Larrateguy, Luis Ignacio. Centro Privado de Medicina Respiratoria; Argentina
Fil: Larrateguy, Santiago Darío. Centro Privado de Medicina Respiratoria; Argentina
Fil: Schlotthauer, Gaston. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería. Departamento de Matemática e Informática. Laboratorio de Señales y Dinámicas no Lineales; Argentina
Materia
SLEEP APNEA SYNDROMES
SLEEPINESS
WAKEFULNESS
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/142919

id CONICETDig_8e5d4f2c6fa4be685106b6a9a6d393af
oai_identifier_str oai:ri.conicet.gov.ar:11336/142919
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Simplified sleep resistance test for daytime sleepiness detectionLarrateguy, Luis DaríoPais, Carlos MarceloLarrateguy, Luis IgnacioLarrateguy, Santiago DaríoSchlotthauer, GastonSLEEP APNEA SYNDROMESSLEEPINESSWAKEFULNESShttps://purl.org/becyt/ford/2.6https://purl.org/becyt/ford/2Objectives: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. Material and Methods: In the new test, during 20 minute subjects were asked to pass a finger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. Results: The proposed method showed a sensitivity of 100% and a specificity of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the confidence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). Conclusion: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel.Fil: Larrateguy, Luis Darío. Centro Privado de Medicina Respiratoria; ArgentinaFil: Pais, Carlos Marcelo. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; ArgentinaFil: Larrateguy, Luis Ignacio. Centro Privado de Medicina Respiratoria; ArgentinaFil: Larrateguy, Santiago Darío. Centro Privado de Medicina Respiratoria; ArgentinaFil: Schlotthauer, Gaston. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería. Departamento de Matemática e Informática. Laboratorio de Señales y Dinámicas no Lineales; ArgentinaBrazilian Association of Sleep and Latin American Federation of Sleep Societies2020-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/142919Larrateguy, Luis Darío; Pais, Carlos Marcelo; Larrateguy, Luis Ignacio; Larrateguy, Santiago Darío; Schlotthauer, Gaston; Simplified sleep resistance test for daytime sleepiness detection; Brazilian Association of Sleep and Latin American Federation of Sleep Societies; Sleep Science; 14; 2; 6-2020; 164-1681984-0063CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://sleepscience.org.br/export-pdf/2802/aop408.pdfinfo:eu-repo/semantics/altIdentifier/doi/10.5935/1984-0063.20200046info:eu-repo/semantics/altIdentifier/url/https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8340892/info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:44:00Zoai:ri.conicet.gov.ar:11336/142919instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:44:00.506CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Simplified sleep resistance test for daytime sleepiness detection
title Simplified sleep resistance test for daytime sleepiness detection
spellingShingle Simplified sleep resistance test for daytime sleepiness detection
Larrateguy, Luis Darío
SLEEP APNEA SYNDROMES
SLEEPINESS
WAKEFULNESS
title_short Simplified sleep resistance test for daytime sleepiness detection
title_full Simplified sleep resistance test for daytime sleepiness detection
title_fullStr Simplified sleep resistance test for daytime sleepiness detection
title_full_unstemmed Simplified sleep resistance test for daytime sleepiness detection
title_sort Simplified sleep resistance test for daytime sleepiness detection
dc.creator.none.fl_str_mv Larrateguy, Luis Darío
Pais, Carlos Marcelo
Larrateguy, Luis Ignacio
Larrateguy, Santiago Darío
Schlotthauer, Gaston
author Larrateguy, Luis Darío
author_facet Larrateguy, Luis Darío
Pais, Carlos Marcelo
Larrateguy, Luis Ignacio
Larrateguy, Santiago Darío
Schlotthauer, Gaston
author_role author
author2 Pais, Carlos Marcelo
Larrateguy, Luis Ignacio
Larrateguy, Santiago Darío
Schlotthauer, Gaston
author2_role author
author
author
author
dc.subject.none.fl_str_mv SLEEP APNEA SYNDROMES
SLEEPINESS
WAKEFULNESS
topic SLEEP APNEA SYNDROMES
SLEEPINESS
WAKEFULNESS
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.6
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv Objectives: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. Material and Methods: In the new test, during 20 minute subjects were asked to pass a finger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. Results: The proposed method showed a sensitivity of 100% and a specificity of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the confidence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). Conclusion: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel.
Fil: Larrateguy, Luis Darío. Centro Privado de Medicina Respiratoria; Argentina
Fil: Pais, Carlos Marcelo. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina
Fil: Larrateguy, Luis Ignacio. Centro Privado de Medicina Respiratoria; Argentina
Fil: Larrateguy, Santiago Darío. Centro Privado de Medicina Respiratoria; Argentina
Fil: Schlotthauer, Gaston. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina. Universidad Nacional de Entre Ríos. Facultad de Ingeniería. Departamento de Matemática e Informática. Laboratorio de Señales y Dinámicas no Lineales; Argentina
description Objectives: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. Material and Methods: In the new test, during 20 minute subjects were asked to pass a finger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. Results: The proposed method showed a sensitivity of 100% and a specificity of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the confidence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). Conclusion: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel.
publishDate 2020
dc.date.none.fl_str_mv 2020-06
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/142919
Larrateguy, Luis Darío; Pais, Carlos Marcelo; Larrateguy, Luis Ignacio; Larrateguy, Santiago Darío; Schlotthauer, Gaston; Simplified sleep resistance test for daytime sleepiness detection; Brazilian Association of Sleep and Latin American Federation of Sleep Societies; Sleep Science; 14; 2; 6-2020; 164-168
1984-0063
CONICET Digital
CONICET
url http://hdl.handle.net/11336/142919
identifier_str_mv Larrateguy, Luis Darío; Pais, Carlos Marcelo; Larrateguy, Luis Ignacio; Larrateguy, Santiago Darío; Schlotthauer, Gaston; Simplified sleep resistance test for daytime sleepiness detection; Brazilian Association of Sleep and Latin American Federation of Sleep Societies; Sleep Science; 14; 2; 6-2020; 164-168
1984-0063
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://sleepscience.org.br/export-pdf/2802/aop408.pdf
info:eu-repo/semantics/altIdentifier/doi/10.5935/1984-0063.20200046
info:eu-repo/semantics/altIdentifier/url/https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8340892/
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Brazilian Association of Sleep and Latin American Federation of Sleep Societies
publisher.none.fl_str_mv Brazilian Association of Sleep and Latin American Federation of Sleep Societies
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842268638319476736
score 13.13397