A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation

Autores
Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; del Sole, Maria Jose; Clausse, Alejandro
Año de publicación
2020
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.
Fil: Clausse, María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina
Fil: Nejamkin, Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias. Departamento de Fisiopatología. Laboratorio de Farmacología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Bulant, Carlos Alberto. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Genaro, Ariel. Instituto de Profesorado de Arte Tandil; Argentina
Fil: Landivar, Florencia. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias; Argentina
Fil: del Sole, Maria Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina
Fil: Clausse, Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Materia
CAT MANIKIN
ENDOTRACHEAL INTUBATION
THREE-DIMENSIONAL PRINTING
TRAINING
UPPER AIRWAY MANAGEMENT
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/118008

id CONICETDig_6b02836907fc37b5da037ae20f5fc1f2
oai_identifier_str oai:ri.conicet.gov.ar:11336/118008
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubationClausse, MaríaNejamkin, PabloBulant, Carlos AlbertoGenaro, ArielLandivar, Florenciadel Sole, Maria JoseClausse, AlejandroCAT MANIKINENDOTRACHEAL INTUBATIONTHREE-DIMENSIONAL PRINTINGTRAININGUPPER AIRWAY MANAGEMENThttps://purl.org/becyt/ford/4.3https://purl.org/becyt/ford/4https://purl.org/becyt/ford/2.11https://purl.org/becyt/ford/2Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.Fil: Clausse, María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; ArgentinaFil: Nejamkin, Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias. Departamento de Fisiopatología. Laboratorio de Farmacología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Bulant, Carlos Alberto. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Genaro, Ariel. Instituto de Profesorado de Arte Tandil; ArgentinaFil: Landivar, Florencia. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias; ArgentinaFil: del Sole, Maria Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; ArgentinaFil: Clausse, Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaWiley Blackwell Publishing, Inc2020-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/118008Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; et al.; A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation; Wiley Blackwell Publishing, Inc; Veterinary Anaesthesia And Analgesia; 47; 5; 9-2020; 676-6801467-2987CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S1467298720301033info:eu-repo/semantics/altIdentifier/doi/10.1016/j.vaa.2020.05.006info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-10T13:00:26Zoai:ri.conicet.gov.ar:11336/118008instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-10 13:00:26.381CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
title A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
spellingShingle A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
Clausse, María
CAT MANIKIN
ENDOTRACHEAL INTUBATION
THREE-DIMENSIONAL PRINTING
TRAINING
UPPER AIRWAY MANAGEMENT
title_short A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
title_full A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
title_fullStr A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
title_full_unstemmed A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
title_sort A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
dc.creator.none.fl_str_mv Clausse, María
Nejamkin, Pablo
Bulant, Carlos Alberto
Genaro, Ariel
Landivar, Florencia
del Sole, Maria Jose
Clausse, Alejandro
author Clausse, María
author_facet Clausse, María
Nejamkin, Pablo
Bulant, Carlos Alberto
Genaro, Ariel
Landivar, Florencia
del Sole, Maria Jose
Clausse, Alejandro
author_role author
author2 Nejamkin, Pablo
Bulant, Carlos Alberto
Genaro, Ariel
Landivar, Florencia
del Sole, Maria Jose
Clausse, Alejandro
author2_role author
author
author
author
author
author
dc.subject.none.fl_str_mv CAT MANIKIN
ENDOTRACHEAL INTUBATION
THREE-DIMENSIONAL PRINTING
TRAINING
UPPER AIRWAY MANAGEMENT
topic CAT MANIKIN
ENDOTRACHEAL INTUBATION
THREE-DIMENSIONAL PRINTING
TRAINING
UPPER AIRWAY MANAGEMENT
purl_subject.fl_str_mv https://purl.org/becyt/ford/4.3
https://purl.org/becyt/ford/4
https://purl.org/becyt/ford/2.11
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.
Fil: Clausse, María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina
Fil: Nejamkin, Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias. Departamento de Fisiopatología. Laboratorio de Farmacología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Bulant, Carlos Alberto. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Genaro, Ariel. Instituto de Profesorado de Arte Tandil; Argentina
Fil: Landivar, Florencia. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias; Argentina
Fil: del Sole, Maria Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina
Fil: Clausse, Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
description Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.
publishDate 2020
dc.date.none.fl_str_mv 2020-09
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/118008
Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; et al.; A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation; Wiley Blackwell Publishing, Inc; Veterinary Anaesthesia And Analgesia; 47; 5; 9-2020; 676-680
1467-2987
CONICET Digital
CONICET
url http://hdl.handle.net/11336/118008
identifier_str_mv Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; et al.; A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation; Wiley Blackwell Publishing, Inc; Veterinary Anaesthesia And Analgesia; 47; 5; 9-2020; 676-680
1467-2987
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S1467298720301033
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.vaa.2020.05.006
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Wiley Blackwell Publishing, Inc
publisher.none.fl_str_mv Wiley Blackwell Publishing, Inc
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842979880913862656
score 12.48226