A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation
- Autores
- Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; del Sole, Maria Jose; Clausse, Alejandro
- Año de publicación
- 2020
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.
Fil: Clausse, María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina
Fil: Nejamkin, Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias. Departamento de Fisiopatología. Laboratorio de Farmacología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Bulant, Carlos Alberto. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina
Fil: Genaro, Ariel. Instituto de Profesorado de Arte Tandil; Argentina
Fil: Landivar, Florencia. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias; Argentina
Fil: del Sole, Maria Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina
Fil: Clausse, Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina - Materia
-
CAT MANIKIN
ENDOTRACHEAL INTUBATION
THREE-DIMENSIONAL PRINTING
TRAINING
UPPER AIRWAY MANAGEMENT - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/118008
Ver los metadatos del registro completo
id |
CONICETDig_6b02836907fc37b5da037ae20f5fc1f2 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/118008 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubationClausse, MaríaNejamkin, PabloBulant, Carlos AlbertoGenaro, ArielLandivar, Florenciadel Sole, Maria JoseClausse, AlejandroCAT MANIKINENDOTRACHEAL INTUBATIONTHREE-DIMENSIONAL PRINTINGTRAININGUPPER AIRWAY MANAGEMENThttps://purl.org/becyt/ford/4.3https://purl.org/becyt/ford/4https://purl.org/becyt/ford/2.11https://purl.org/becyt/ford/2Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.Fil: Clausse, María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; ArgentinaFil: Nejamkin, Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias. Departamento de Fisiopatología. Laboratorio de Farmacología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Bulant, Carlos Alberto. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaFil: Genaro, Ariel. Instituto de Profesorado de Arte Tandil; ArgentinaFil: Landivar, Florencia. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias; ArgentinaFil: del Sole, Maria Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; ArgentinaFil: Clausse, Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; ArgentinaWiley Blackwell Publishing, Inc2020-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/118008Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; et al.; A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation; Wiley Blackwell Publishing, Inc; Veterinary Anaesthesia And Analgesia; 47; 5; 9-2020; 676-6801467-2987CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S1467298720301033info:eu-repo/semantics/altIdentifier/doi/10.1016/j.vaa.2020.05.006info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-10T13:00:26Zoai:ri.conicet.gov.ar:11336/118008instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-10 13:00:26.381CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation |
title |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation |
spellingShingle |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation Clausse, María CAT MANIKIN ENDOTRACHEAL INTUBATION THREE-DIMENSIONAL PRINTING TRAINING UPPER AIRWAY MANAGEMENT |
title_short |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation |
title_full |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation |
title_fullStr |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation |
title_full_unstemmed |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation |
title_sort |
A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation |
dc.creator.none.fl_str_mv |
Clausse, María Nejamkin, Pablo Bulant, Carlos Alberto Genaro, Ariel Landivar, Florencia del Sole, Maria Jose Clausse, Alejandro |
author |
Clausse, María |
author_facet |
Clausse, María Nejamkin, Pablo Bulant, Carlos Alberto Genaro, Ariel Landivar, Florencia del Sole, Maria Jose Clausse, Alejandro |
author_role |
author |
author2 |
Nejamkin, Pablo Bulant, Carlos Alberto Genaro, Ariel Landivar, Florencia del Sole, Maria Jose Clausse, Alejandro |
author2_role |
author author author author author author |
dc.subject.none.fl_str_mv |
CAT MANIKIN ENDOTRACHEAL INTUBATION THREE-DIMENSIONAL PRINTING TRAINING UPPER AIRWAY MANAGEMENT |
topic |
CAT MANIKIN ENDOTRACHEAL INTUBATION THREE-DIMENSIONAL PRINTING TRAINING UPPER AIRWAY MANAGEMENT |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/4.3 https://purl.org/becyt/ford/4 https://purl.org/becyt/ford/2.11 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced. Fil: Clausse, María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina Fil: Nejamkin, Pablo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias. Departamento de Fisiopatología. Laboratorio de Farmacología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina Fil: Bulant, Carlos Alberto. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina Fil: Genaro, Ariel. Instituto de Profesorado de Arte Tandil; Argentina Fil: Landivar, Florencia. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Veterinarias; Argentina Fil: del Sole, Maria Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil. Centro de Investigación Veterinaria de Tandil. Universidad Nacional del Centro de la Provincia de Buenos Aires. Centro de Investigación Veterinaria de Tandil. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Centro de Investigación Veterinaria de Tandil; Argentina Fil: Clausse, Alejandro. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Grupo de Plasmas Densos Magnetizados. Provincia de Buenos Aires. Gobernación. Comision de Investigaciones Científicas. Grupo de Plasmas Densos Magnetizados; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tandil; Argentina |
description |
Objective: To design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication. Study design: Research and development study. Animals: A domestic cat. Methods: The cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire. Results: Several preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure. Conclusions: and clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-09 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/118008 Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; et al.; A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation; Wiley Blackwell Publishing, Inc; Veterinary Anaesthesia And Analgesia; 47; 5; 9-2020; 676-680 1467-2987 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/118008 |
identifier_str_mv |
Clausse, María; Nejamkin, Pablo; Bulant, Carlos Alberto; Genaro, Ariel; Landivar, Florencia; et al.; A low-cost portable simulator of a domestic cat larynx for teaching endotracheal intubation; Wiley Blackwell Publishing, Inc; Veterinary Anaesthesia And Analgesia; 47; 5; 9-2020; 676-680 1467-2987 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S1467298720301033 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.vaa.2020.05.006 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Wiley Blackwell Publishing, Inc |
publisher.none.fl_str_mv |
Wiley Blackwell Publishing, Inc |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842979880913862656 |
score |
12.48226 |