Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)

Autores
Molina, Pablo Fernando; Ortega, F.; Marcazzo, Salvador Julian; Santiago, Martin Alejo; Spano, F.; Caselli, Eduardo Eladio
Año de publicación
2015
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
The kinetic parameters of dosimetric peaks of CaF2:Tm (TLD-300) were found by employing a kinetics model derived from differential equations describing the carriers traffic but without resorting to the quasi-equilibrium approximation. Since both shape and position of glow peaks were observed not to change with dose, retrapping rates have been assumed negligible compared to rates of thermal release of electrons. The reported results show that the quasi-equilibrium approximation does not hold, an approximation used for derivation of first order kinetics, which is the kinetics employed so far for analyzing glow curves of the TLD-300.
Fil: Molina, Pablo Fernando. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Ortega, F.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Marcazzo, Salvador Julian. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Santiago, Martin Alejo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Spano, F.. Autoridad Regulatoria Nuclear; Argentina
Fil: Caselli, Eduardo Eladio. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas; Argentina
Materia
Thermoluminescence
Deconvolution
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/4585

id CONICETDig_66cff42b39177e1b7854c9d7a2e85a17
oai_identifier_str oai:ri.conicet.gov.ar:11336/4585
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)Molina, Pablo FernandoOrtega, F.Marcazzo, Salvador JulianSantiago, Martin AlejoSpano, F.Caselli, Eduardo EladioThermoluminescenceDeconvolutionhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1The kinetic parameters of dosimetric peaks of CaF2:Tm (TLD-300) were found by employing a kinetics model derived from differential equations describing the carriers traffic but without resorting to the quasi-equilibrium approximation. Since both shape and position of glow peaks were observed not to change with dose, retrapping rates have been assumed negligible compared to rates of thermal release of electrons. The reported results show that the quasi-equilibrium approximation does not hold, an approximation used for derivation of first order kinetics, which is the kinetics employed so far for analyzing glow curves of the TLD-300.Fil: Molina, Pablo Fernando. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Ortega, F.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Marcazzo, Salvador Julian. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Santiago, Martin Alejo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; ArgentinaFil: Spano, F.. Autoridad Regulatoria Nuclear; ArgentinaFil: Caselli, Eduardo Eladio. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas; ArgentinaElsevier2015-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/4585Molina, Pablo Fernando; Ortega, F.; Marcazzo, Salvador Julian; Santiago, Martin Alejo; Spano, F.; et al.; Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300); Elsevier; Radiation Measurements; 82; 3-2015; 83-871350-4487enginfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S1350448715300603info:eu-repo/semantics/altIdentifier/doi/10.1016/j.radmeas.2015.08.006info:eu-repo/semantics/altIdentifier/issn/1350-4487info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:46:47Zoai:ri.conicet.gov.ar:11336/4585instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:46:47.947CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
title Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
spellingShingle Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
Molina, Pablo Fernando
Thermoluminescence
Deconvolution
title_short Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
title_full Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
title_fullStr Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
title_full_unstemmed Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
title_sort Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300)
dc.creator.none.fl_str_mv Molina, Pablo Fernando
Ortega, F.
Marcazzo, Salvador Julian
Santiago, Martin Alejo
Spano, F.
Caselli, Eduardo Eladio
author Molina, Pablo Fernando
author_facet Molina, Pablo Fernando
Ortega, F.
Marcazzo, Salvador Julian
Santiago, Martin Alejo
Spano, F.
Caselli, Eduardo Eladio
author_role author
author2 Ortega, F.
Marcazzo, Salvador Julian
Santiago, Martin Alejo
Spano, F.
Caselli, Eduardo Eladio
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv Thermoluminescence
Deconvolution
topic Thermoluminescence
Deconvolution
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv The kinetic parameters of dosimetric peaks of CaF2:Tm (TLD-300) were found by employing a kinetics model derived from differential equations describing the carriers traffic but without resorting to the quasi-equilibrium approximation. Since both shape and position of glow peaks were observed not to change with dose, retrapping rates have been assumed negligible compared to rates of thermal release of electrons. The reported results show that the quasi-equilibrium approximation does not hold, an approximation used for derivation of first order kinetics, which is the kinetics employed so far for analyzing glow curves of the TLD-300.
Fil: Molina, Pablo Fernando. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Ortega, F.. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Marcazzo, Salvador Julian. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Santiago, Martin Alejo. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina
Fil: Spano, F.. Autoridad Regulatoria Nuclear; Argentina
Fil: Caselli, Eduardo Eladio. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Instituto de Fisica Arroyo Seco; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tandil. Centro de Investigaciones en Física e Ingeniería del Centro de la Provincia de Buenos Aires; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas; Argentina
description The kinetic parameters of dosimetric peaks of CaF2:Tm (TLD-300) were found by employing a kinetics model derived from differential equations describing the carriers traffic but without resorting to the quasi-equilibrium approximation. Since both shape and position of glow peaks were observed not to change with dose, retrapping rates have been assumed negligible compared to rates of thermal release of electrons. The reported results show that the quasi-equilibrium approximation does not hold, an approximation used for derivation of first order kinetics, which is the kinetics employed so far for analyzing glow curves of the TLD-300.
publishDate 2015
dc.date.none.fl_str_mv 2015-03
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/4585
Molina, Pablo Fernando; Ortega, F.; Marcazzo, Salvador Julian; Santiago, Martin Alejo; Spano, F.; et al.; Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300); Elsevier; Radiation Measurements; 82; 3-2015; 83-87
1350-4487
url http://hdl.handle.net/11336/4585
identifier_str_mv Molina, Pablo Fernando; Ortega, F.; Marcazzo, Salvador Julian; Santiago, Martin Alejo; Spano, F.; et al.; Trap parameters of dosimetric glow peaks of the CaF2:Tm compounds (TLD-300); Elsevier; Radiation Measurements; 82; 3-2015; 83-87
1350-4487
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S1350448715300603
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.radmeas.2015.08.006
info:eu-repo/semantics/altIdentifier/issn/1350-4487
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614510090911744
score 13.070432