Foveal spatial summation in human cone mechanism
- Autores
- O´donell, Beatriz Maria; Colombo, Elisa Margarita
- Año de publicación
- 2011
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- We measured at the fovea the chromatic contrast threshold for stimuli modulated along different chromatic directions in the isoluminant plane of MBDKL colour space, considering the two cardinal axes (L+M) and S/(L+M) and other intermediate non-cardinal directions. This psychophysical determination was conducted as a function of stimulus size. The test stimulus was a foveal isoluminant Gaussian patch with a raised cosinusoidal temporal profile superimposed on a neutral background. The task was performed binocularly. The increment threshold was measured for three observers by a Bayesian adaptive psychometric method (QUEST). The Ricco area of complete spatial summation was estimated from the threshold-versus-area curves. The perceptive fields are smaller for the L/M-cone opponent direction than the S/(L+M)-cone opponent. The perceptive field sizes for the stimuli in non-cardinal chromatic directions and stimuli modulated at the (L/M)-cone opponent direction present similar values. Measurements were made at two luminance levels, 5 and 40 cd m-2, but the differences found were small. The perceptive field sizes found could be associated with LGN area.
Fil: O´DONELL, Beatriz M. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina
Fil: Colombo, Elisa Margarita. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina - Materia
-
Color Vision
Color Perception
Chromatic Mechanisms - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/97093
Ver los metadatos del registro completo
id |
CONICETDig_66c972ba022c9e82057f838f0cdc1d2b |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/97093 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Foveal spatial summation in human cone mechanismO´donell, Beatriz MariaColombo, Elisa MargaritaColor VisionColor PerceptionChromatic Mechanismshttps://purl.org/becyt/ford/2.11https://purl.org/becyt/ford/2We measured at the fovea the chromatic contrast threshold for stimuli modulated along different chromatic directions in the isoluminant plane of MBDKL colour space, considering the two cardinal axes (L+M) and S/(L+M) and other intermediate non-cardinal directions. This psychophysical determination was conducted as a function of stimulus size. The test stimulus was a foveal isoluminant Gaussian patch with a raised cosinusoidal temporal profile superimposed on a neutral background. The task was performed binocularly. The increment threshold was measured for three observers by a Bayesian adaptive psychometric method (QUEST). The Ricco area of complete spatial summation was estimated from the threshold-versus-area curves. The perceptive fields are smaller for the L/M-cone opponent direction than the S/(L+M)-cone opponent. The perceptive field sizes for the stimuli in non-cardinal chromatic directions and stimuli modulated at the (L/M)-cone opponent direction present similar values. Measurements were made at two luminance levels, 5 and 40 cd m-2, but the differences found were small. The perceptive field sizes found could be associated with LGN area.Fil: O´DONELL, Beatriz M. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; ArgentinaFil: Colombo, Elisa Margarita. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; ArgentinaPion Ltd2011-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/97093O´donell, Beatriz Maria; Colombo, Elisa Margarita; Foveal spatial summation in human cone mechanism; Pion Ltd; Perception; 40; 1; 8-2011; 50-620301-0066CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1068/p6775info:eu-repo/semantics/altIdentifier/url/https://journals.sagepub.com/doi/10.1068/p6775info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T15:18:06Zoai:ri.conicet.gov.ar:11336/97093instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 15:18:06.741CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Foveal spatial summation in human cone mechanism |
title |
Foveal spatial summation in human cone mechanism |
spellingShingle |
Foveal spatial summation in human cone mechanism O´donell, Beatriz Maria Color Vision Color Perception Chromatic Mechanisms |
title_short |
Foveal spatial summation in human cone mechanism |
title_full |
Foveal spatial summation in human cone mechanism |
title_fullStr |
Foveal spatial summation in human cone mechanism |
title_full_unstemmed |
Foveal spatial summation in human cone mechanism |
title_sort |
Foveal spatial summation in human cone mechanism |
dc.creator.none.fl_str_mv |
O´donell, Beatriz Maria Colombo, Elisa Margarita |
author |
O´donell, Beatriz Maria |
author_facet |
O´donell, Beatriz Maria Colombo, Elisa Margarita |
author_role |
author |
author2 |
Colombo, Elisa Margarita |
author2_role |
author |
dc.subject.none.fl_str_mv |
Color Vision Color Perception Chromatic Mechanisms |
topic |
Color Vision Color Perception Chromatic Mechanisms |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.11 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
We measured at the fovea the chromatic contrast threshold for stimuli modulated along different chromatic directions in the isoluminant plane of MBDKL colour space, considering the two cardinal axes (L+M) and S/(L+M) and other intermediate non-cardinal directions. This psychophysical determination was conducted as a function of stimulus size. The test stimulus was a foveal isoluminant Gaussian patch with a raised cosinusoidal temporal profile superimposed on a neutral background. The task was performed binocularly. The increment threshold was measured for three observers by a Bayesian adaptive psychometric method (QUEST). The Ricco area of complete spatial summation was estimated from the threshold-versus-area curves. The perceptive fields are smaller for the L/M-cone opponent direction than the S/(L+M)-cone opponent. The perceptive field sizes for the stimuli in non-cardinal chromatic directions and stimuli modulated at the (L/M)-cone opponent direction present similar values. Measurements were made at two luminance levels, 5 and 40 cd m-2, but the differences found were small. The perceptive field sizes found could be associated with LGN area. Fil: O´DONELL, Beatriz M. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina Fil: Colombo, Elisa Margarita. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Luminotecnia, Luz y Visión; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina |
description |
We measured at the fovea the chromatic contrast threshold for stimuli modulated along different chromatic directions in the isoluminant plane of MBDKL colour space, considering the two cardinal axes (L+M) and S/(L+M) and other intermediate non-cardinal directions. This psychophysical determination was conducted as a function of stimulus size. The test stimulus was a foveal isoluminant Gaussian patch with a raised cosinusoidal temporal profile superimposed on a neutral background. The task was performed binocularly. The increment threshold was measured for three observers by a Bayesian adaptive psychometric method (QUEST). The Ricco area of complete spatial summation was estimated from the threshold-versus-area curves. The perceptive fields are smaller for the L/M-cone opponent direction than the S/(L+M)-cone opponent. The perceptive field sizes for the stimuli in non-cardinal chromatic directions and stimuli modulated at the (L/M)-cone opponent direction present similar values. Measurements were made at two luminance levels, 5 and 40 cd m-2, but the differences found were small. The perceptive field sizes found could be associated with LGN area. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-08 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/97093 O´donell, Beatriz Maria; Colombo, Elisa Margarita; Foveal spatial summation in human cone mechanism; Pion Ltd; Perception; 40; 1; 8-2011; 50-62 0301-0066 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/97093 |
identifier_str_mv |
O´donell, Beatriz Maria; Colombo, Elisa Margarita; Foveal spatial summation in human cone mechanism; Pion Ltd; Perception; 40; 1; 8-2011; 50-62 0301-0066 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1068/p6775 info:eu-repo/semantics/altIdentifier/url/https://journals.sagepub.com/doi/10.1068/p6775 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Pion Ltd |
publisher.none.fl_str_mv |
Pion Ltd |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1846083329927938048 |
score |
13.22299 |