Grupa LOTOS, a vertically integrated oil company working in the field of crude oil production, refining, and oil products distribution, employs an online model, Visual MESA, to monitor and optimize the energy system. The energy system is based around several steam pressure levels, with a set of fired boilers producing high pressure steam, a set of steam turbo generators producing electricity, and a set of process heaters which can run with fuel gas and fuel oil. The steps of the system include data collection and control system review, software installation, model building and optimization configuration, midpoint review and users training, and burn in period. An important monitoring aspect of the system include the continuous auditing of the energy system so the data can be relied on for evaluating the value of energy production and usage, and waste can be eliminated. Imbalances are flagged graphically by using balloons of different colors and sizes.
Fil: Majchrowicz, J.. Grupa Lotos S.a., Gdansk Refinery; Polonia
Fil: Herra, M.. Grupa Lotos S.a., Gdansk Refinery; Polonia
Fil: Serralunga, Fernán José. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo y Diseño. Universidad Tecnológica Nacional. Facultad Regional Santa Fe. Instituto de Desarrollo y Diseño; Argentina
Fil: Ruiz, D.. Soteica Europe S.l.; España
Materia
Energy Optimization
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/70215

id CONICETDig_61e89646294ce56d086b044b02977213
oai_identifier_str oai:ri.conicet.gov.ar:11336/70215
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Energy Management: A polish case studyMajchrowicz, J.Herra, M.Serralunga, Fernán JoséRuiz, D.Energy Optimizationhttps://purl.org/becyt/ford/2.4https://purl.org/becyt/ford/2Grupa LOTOS, a vertically integrated oil company working in the field of crude oil production, refining, and oil products distribution, employs an online model, Visual MESA, to monitor and optimize the energy system. The energy system is based around several steam pressure levels, with a set of fired boilers producing high pressure steam, a set of steam turbo generators producing electricity, and a set of process heaters which can run with fuel gas and fuel oil. The steps of the system include data collection and control system review, software installation, model building and optimization configuration, midpoint review and users training, and burn in period. An important monitoring aspect of the system include the continuous auditing of the energy system so the data can be relied on for evaluating the value of energy production and usage, and waste can be eliminated. Imbalances are flagged graphically by using balloons of different colors and sizes.Fil: Majchrowicz, J.. Grupa Lotos S.a., Gdansk Refinery; PoloniaFil: Herra, M.. Grupa Lotos S.a., Gdansk Refinery; PoloniaFil: Serralunga, Fernán José. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo y Diseño. Universidad Tecnológica Nacional. Facultad Regional Santa Fe. Instituto de Desarrollo y Diseño; ArgentinaFil: Ruiz, D.. Soteica Europe S.l.; EspañaPalladian Publications2011-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/70215Majchrowicz, J.; Herra, M.; Serralunga, Fernán José; Ruiz, D.; Energy Management: A polish case study; Palladian Publications; Hydrocarbon Engineering; 16; 9; 9-2011; 40-461468-9340CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.energyglobal.com/magazines/issue.aspx?seo=hydrocarbon-engineering&month=9&year=2011info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T15:14:01Zoai:ri.conicet.gov.ar:11336/70215instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 15:14:02.219CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Energy Management: A polish case study
title Energy Management: A polish case study
spellingShingle Energy Management: A polish case study
Majchrowicz, J.
Energy Optimization
title_short Energy Management: A polish case study
title_full Energy Management: A polish case study
title_fullStr Energy Management: A polish case study
title_full_unstemmed Energy Management: A polish case study
title_sort Energy Management: A polish case study
dc.creator.none.fl_str_mv Majchrowicz, J.
Herra, M.
Serralunga, Fernán José
Ruiz, D.
author Majchrowicz, J.
author_facet Majchrowicz, J.
Herra, M.
Serralunga, Fernán José
Ruiz, D.
author_role author
author2 Herra, M.
Serralunga, Fernán José
Ruiz, D.
author2_role author
author
author
dc.subject.none.fl_str_mv Energy Optimization
topic Energy Optimization
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.4
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv Grupa LOTOS, a vertically integrated oil company working in the field of crude oil production, refining, and oil products distribution, employs an online model, Visual MESA, to monitor and optimize the energy system. The energy system is based around several steam pressure levels, with a set of fired boilers producing high pressure steam, a set of steam turbo generators producing electricity, and a set of process heaters which can run with fuel gas and fuel oil. The steps of the system include data collection and control system review, software installation, model building and optimization configuration, midpoint review and users training, and burn in period. An important monitoring aspect of the system include the continuous auditing of the energy system so the data can be relied on for evaluating the value of energy production and usage, and waste can be eliminated. Imbalances are flagged graphically by using balloons of different colors and sizes.
Fil: Majchrowicz, J.. Grupa Lotos S.a., Gdansk Refinery; Polonia
Fil: Herra, M.. Grupa Lotos S.a., Gdansk Refinery; Polonia
Fil: Serralunga, Fernán José. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo y Diseño. Universidad Tecnológica Nacional. Facultad Regional Santa Fe. Instituto de Desarrollo y Diseño; Argentina
Fil: Ruiz, D.. Soteica Europe S.l.; España
description Grupa LOTOS, a vertically integrated oil company working in the field of crude oil production, refining, and oil products distribution, employs an online model, Visual MESA, to monitor and optimize the energy system. The energy system is based around several steam pressure levels, with a set of fired boilers producing high pressure steam, a set of steam turbo generators producing electricity, and a set of process heaters which can run with fuel gas and fuel oil. The steps of the system include data collection and control system review, software installation, model building and optimization configuration, midpoint review and users training, and burn in period. An important monitoring aspect of the system include the continuous auditing of the energy system so the data can be relied on for evaluating the value of energy production and usage, and waste can be eliminated. Imbalances are flagged graphically by using balloons of different colors and sizes.
publishDate 2011
dc.date.none.fl_str_mv 2011-09
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/70215
Majchrowicz, J.; Herra, M.; Serralunga, Fernán José; Ruiz, D.; Energy Management: A polish case study; Palladian Publications; Hydrocarbon Engineering; 16; 9; 9-2011; 40-46
1468-9340
CONICET Digital
CONICET
url http://hdl.handle.net/11336/70215
identifier_str_mv Majchrowicz, J.; Herra, M.; Serralunga, Fernán José; Ruiz, D.; Energy Management: A polish case study; Palladian Publications; Hydrocarbon Engineering; 16; 9; 9-2011; 40-46
1468-9340
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://www.energyglobal.com/magazines/issue.aspx?seo=hydrocarbon-engineering&month=9&year=2011
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Palladian Publications
publisher.none.fl_str_mv Palladian Publications
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1846083287340023808
score 13.22299