Absolute calibration of a large-diameter light source

Autores
Brack, J. T.; Cope, R.; Dorofeev, A.; Gookin, B.; Harton, J. L.; Petrov, Y.; Rovero, Adrian Carlos
Año de publicación
2013
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra-violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.
Fil: Brack, J. T.. Colorado State University; Estados Unidos
Fil: Cope, R.. Colorado State University; Estados Unidos
Fil: Dorofeev, A.. Colorado State University; Estados Unidos
Fil: Gookin, B.. Colorado State University; Estados Unidos
Fil: Harton, J. L.. Colorado State University; Estados Unidos
Fil: Petrov, Y.. Colorado State University; Estados Unidos
Fil: Rovero, Adrian Carlos. Consejo Nacional de Investigaciónes Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Astronomía y Física del Espacio. - Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Astronomía y Física del Espacio; Argentina
Materia
ABSOLUTE CALIBRATION
DETECTORS FOR UV
OPTICS: LARGE DETECTOR SYSTEMS
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/17075

id CONICETDig_5f322162e9565eb95740d8023f45e725
oai_identifier_str oai:ri.conicet.gov.ar:11336/17075
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Absolute calibration of a large-diameter light sourceBrack, J. T.Cope, R.Dorofeev, A.Gookin, B.Harton, J. L.Petrov, Y.Rovero, Adrian CarlosABSOLUTE CALIBRATIONDETECTORS FOR UVOPTICS: LARGE DETECTOR SYSTEMShttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra-violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.Fil: Brack, J. T.. Colorado State University; Estados UnidosFil: Cope, R.. Colorado State University; Estados UnidosFil: Dorofeev, A.. Colorado State University; Estados UnidosFil: Gookin, B.. Colorado State University; Estados UnidosFil: Harton, J. L.. Colorado State University; Estados UnidosFil: Petrov, Y.. Colorado State University; Estados UnidosFil: Rovero, Adrian Carlos. Consejo Nacional de Investigaciónes Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Astronomía y Física del Espacio. - Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Astronomía y Física del Espacio; ArgentinaIop Publishing2013-05-23info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/17075Brack, J. T.; Cope, R.; Dorofeev, A.; Gookin, B.; Harton, J. L.; et al.; Absolute calibration of a large-diameter light source; Iop Publishing; Journal Of Instrumentation; 8; 23-5-2013; 5014, 1-161748-0221enginfo:eu-repo/semantics/altIdentifier/doi/10.1088/1748-0221/8/05/P05014info:eu-repo/semantics/altIdentifier/url/http://iopscience.iop.org/article/10.1088/1748-0221/8/05/P05014/metainfo:eu-repo/semantics/altIdentifier/arxiv/https://arxiv.org/abs/1305.1329info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T10:07:33Zoai:ri.conicet.gov.ar:11336/17075instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 10:07:33.856CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Absolute calibration of a large-diameter light source
title Absolute calibration of a large-diameter light source
spellingShingle Absolute calibration of a large-diameter light source
Brack, J. T.
ABSOLUTE CALIBRATION
DETECTORS FOR UV
OPTICS: LARGE DETECTOR SYSTEMS
title_short Absolute calibration of a large-diameter light source
title_full Absolute calibration of a large-diameter light source
title_fullStr Absolute calibration of a large-diameter light source
title_full_unstemmed Absolute calibration of a large-diameter light source
title_sort Absolute calibration of a large-diameter light source
dc.creator.none.fl_str_mv Brack, J. T.
Cope, R.
Dorofeev, A.
Gookin, B.
Harton, J. L.
Petrov, Y.
Rovero, Adrian Carlos
author Brack, J. T.
author_facet Brack, J. T.
Cope, R.
Dorofeev, A.
Gookin, B.
Harton, J. L.
Petrov, Y.
Rovero, Adrian Carlos
author_role author
author2 Cope, R.
Dorofeev, A.
Gookin, B.
Harton, J. L.
Petrov, Y.
Rovero, Adrian Carlos
author2_role author
author
author
author
author
author
dc.subject.none.fl_str_mv ABSOLUTE CALIBRATION
DETECTORS FOR UV
OPTICS: LARGE DETECTOR SYSTEMS
topic ABSOLUTE CALIBRATION
DETECTORS FOR UV
OPTICS: LARGE DETECTOR SYSTEMS
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra-violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.
Fil: Brack, J. T.. Colorado State University; Estados Unidos
Fil: Cope, R.. Colorado State University; Estados Unidos
Fil: Dorofeev, A.. Colorado State University; Estados Unidos
Fil: Gookin, B.. Colorado State University; Estados Unidos
Fil: Harton, J. L.. Colorado State University; Estados Unidos
Fil: Petrov, Y.. Colorado State University; Estados Unidos
Fil: Rovero, Adrian Carlos. Consejo Nacional de Investigaciónes Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Instituto de Astronomía y Física del Espacio. - Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Instituto de Astronomía y Física del Espacio; Argentina
description A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra-violet light emitting diode is calibrated with an overall uncertainty of 2.1 % at a wavelength of 365 nm.
publishDate 2013
dc.date.none.fl_str_mv 2013-05-23
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/17075
Brack, J. T.; Cope, R.; Dorofeev, A.; Gookin, B.; Harton, J. L.; et al.; Absolute calibration of a large-diameter light source; Iop Publishing; Journal Of Instrumentation; 8; 23-5-2013; 5014, 1-16
1748-0221
url http://hdl.handle.net/11336/17075
identifier_str_mv Brack, J. T.; Cope, R.; Dorofeev, A.; Gookin, B.; Harton, J. L.; et al.; Absolute calibration of a large-diameter light source; Iop Publishing; Journal Of Instrumentation; 8; 23-5-2013; 5014, 1-16
1748-0221
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1088/1748-0221/8/05/P05014
info:eu-repo/semantics/altIdentifier/url/http://iopscience.iop.org/article/10.1088/1748-0221/8/05/P05014/meta
info:eu-repo/semantics/altIdentifier/arxiv/https://arxiv.org/abs/1305.1329
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Iop Publishing
publisher.none.fl_str_mv Iop Publishing
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842270007127441408
score 13.13397