Heat transfer in a simulated spent fuel pool for different types of spent fuels
- Autores
- de Faria, Fernando Pereira; Godino, Dario Martin; Corzo, Santiago Francisco; Ramajo, Damian Enrique; Costa, Antonella Lombardi; Pereira, Claubia
- Año de publicación
- 2023
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Historically, the Spent Fuel Pool (SFP) of Angra II, from Brazil, has received standard spent fuel (SF) assemblies of uranium dioxide (UO2) discharged from Pressurized Water Reactors (PWR) of the Nuclear Power Plants (NPP) of Angra. However, in case of using Mixed Oxide (MOX) or thorium-based fuels at a proportion of 1/3 or 1/4 of the total of fuel assemblies in their PWRs as it has been occurring worldwide, it would require further thermal studies of wet storage of the new mixed SF generated. It includes the determination of the water boiling time (Tb) of the SFP in case of breakdown of its external cooling system (ECS). This work presents studies of Tb of a simulated SFP storing mixed SF discharged from PWRs. The types of mixed SF studied include MOX plus UO2, oxide of thorium/uranium (U-Th)O2 plus UO2, and oxide of thorium/transuranic (TRU-Th)O2 plus UO2. All the mixed SF was considered to contain 1/3 or 1/4 of either thorium-based fuels or reprocessed fuel. The simulations were implemented in CFX Ansys and OpenFOAM© codes. Tb from simulations with Ansys ranged from 4.05 h to 5.97 h, and from 3.45 h to 5.77 h from simulations with OpenFOAM©. Results show that, independent of the mixed loading pattern of the SFP, the water would reach the saturation temperature more rapidly when (TRU-Th)O2 was present. By contrast, when MOX was present, Tb was greater.
Historicamente, o Pool de Combustível Irradiado (SFP) de Angra II, do Brasil, tem recebido montagens de combustível padrão gasto (SF) de dióxido de urânio (UO2) descarregado de Reatores de Água Pressurizada (PWR) das Usinas Nucleares (NPP) de Angra. Entretanto, no caso de utilização de combustíveis à base de óxido misto (MOX) ou tório na proporção de 1/3 ou 1/4 do total de conjuntos de combustível em suas PWRs como vem ocorrendo em todo o mundo, seriam necessários mais estudos térmicos de armazenamento úmido do novo SF misto gerado. Inclui a determinação do tempo de ebulição da água (Tb) do SFP em caso de quebra de seu sistema de resfriamento externo (ECS). Este trabalho apresenta estudos de Tb de um SFP simulado de armazenamento de SF misto descarregado de PWRs. Os tipos de SF mistos estudados incluem MOX mais UO2, óxido de tório/urânio (U-Th)O2 mais UO2, e óxido de tório/transurânico (TRUTh)O2 mais UO2. Todo o SF misto foi considerado como contendo 1/3 ou 1/4 de combustíveis à base de tório ou combustível reprocessado. As simulações foram implementadas nos códigos CFX Ansys e OpenFOAM©. Tb de simulações com Ansys variou de 4,05 h a 5,97 h, e de 3,45 h a 5,77 h de simulações com OpenFOAM©. Os resultados mostram que, independente do padrão de carga mista do SFP, a água alcançaria a temperatura de saturação mais rapidamente quando (TRU-Th)O2 estivesse presente. Em contraste, quando MOX estava presente, a Tb era maior.
Fil: de Faria, Fernando Pereira. Departamento de Engenharia Nuclear; Brasil
Fil: Godino, Dario Martin. Universidad Nacional de Rosario. Facultad de Ciencias Exactas Ingeniería y Agrimensura. Escuela de Ingeniería Mecánica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; Argentina
Fil: Corzo, Santiago Francisco. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; Argentina
Fil: Ramajo, Damian Enrique. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; Argentina
Fil: Costa, Antonella Lombardi. Departamento de Engenharia Nuclear; Brasil
Fil: Pereira, Claubia. Departamento de Engenharia Nuclear; Brasil - Materia
-
SPENT FUEL POOL
OPENFOAM
CFX - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/226323
Ver los metadatos del registro completo
id |
CONICETDig_5129df9d24b1d259a39a951edc78c442 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/226323 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Heat transfer in a simulated spent fuel pool for different types of spent fuelsTransferência de calor em um pool simulado de combustível queimado para diferentes tipos de combustíveis queimadosde Faria, Fernando PereiraGodino, Dario MartinCorzo, Santiago FranciscoRamajo, Damian EnriqueCosta, Antonella LombardiPereira, ClaubiaSPENT FUEL POOLOPENFOAMCFXhttps://purl.org/becyt/ford/2.3https://purl.org/becyt/ford/2Historically, the Spent Fuel Pool (SFP) of Angra II, from Brazil, has received standard spent fuel (SF) assemblies of uranium dioxide (UO2) discharged from Pressurized Water Reactors (PWR) of the Nuclear Power Plants (NPP) of Angra. However, in case of using Mixed Oxide (MOX) or thorium-based fuels at a proportion of 1/3 or 1/4 of the total of fuel assemblies in their PWRs as it has been occurring worldwide, it would require further thermal studies of wet storage of the new mixed SF generated. It includes the determination of the water boiling time (Tb) of the SFP in case of breakdown of its external cooling system (ECS). This work presents studies of Tb of a simulated SFP storing mixed SF discharged from PWRs. The types of mixed SF studied include MOX plus UO2, oxide of thorium/uranium (U-Th)O2 plus UO2, and oxide of thorium/transuranic (TRU-Th)O2 plus UO2. All the mixed SF was considered to contain 1/3 or 1/4 of either thorium-based fuels or reprocessed fuel. The simulations were implemented in CFX Ansys and OpenFOAM© codes. Tb from simulations with Ansys ranged from 4.05 h to 5.97 h, and from 3.45 h to 5.77 h from simulations with OpenFOAM©. Results show that, independent of the mixed loading pattern of the SFP, the water would reach the saturation temperature more rapidly when (TRU-Th)O2 was present. By contrast, when MOX was present, Tb was greater.Historicamente, o Pool de Combustível Irradiado (SFP) de Angra II, do Brasil, tem recebido montagens de combustível padrão gasto (SF) de dióxido de urânio (UO2) descarregado de Reatores de Água Pressurizada (PWR) das Usinas Nucleares (NPP) de Angra. Entretanto, no caso de utilização de combustíveis à base de óxido misto (MOX) ou tório na proporção de 1/3 ou 1/4 do total de conjuntos de combustível em suas PWRs como vem ocorrendo em todo o mundo, seriam necessários mais estudos térmicos de armazenamento úmido do novo SF misto gerado. Inclui a determinação do tempo de ebulição da água (Tb) do SFP em caso de quebra de seu sistema de resfriamento externo (ECS). Este trabalho apresenta estudos de Tb de um SFP simulado de armazenamento de SF misto descarregado de PWRs. Os tipos de SF mistos estudados incluem MOX mais UO2, óxido de tório/urânio (U-Th)O2 mais UO2, e óxido de tório/transurânico (TRUTh)O2 mais UO2. Todo o SF misto foi considerado como contendo 1/3 ou 1/4 de combustíveis à base de tório ou combustível reprocessado. As simulações foram implementadas nos códigos CFX Ansys e OpenFOAM©. Tb de simulações com Ansys variou de 4,05 h a 5,97 h, e de 3,45 h a 5,77 h de simulações com OpenFOAM©. Os resultados mostram que, independente do padrão de carga mista do SFP, a água alcançaria a temperatura de saturação mais rapidamente quando (TRU-Th)O2 estivesse presente. Em contraste, quando MOX estava presente, a Tb era maior.Fil: de Faria, Fernando Pereira. Departamento de Engenharia Nuclear; BrasilFil: Godino, Dario Martin. Universidad Nacional de Rosario. Facultad de Ciencias Exactas Ingeniería y Agrimensura. Escuela de Ingeniería Mecánica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Corzo, Santiago Francisco. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Ramajo, Damian Enrique. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; ArgentinaFil: Costa, Antonella Lombardi. Departamento de Engenharia Nuclear; BrasilFil: Pereira, Claubia. Departamento de Engenharia Nuclear; BrasilBrazilian Journal of Development2023-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/226323de Faria, Fernando Pereira ; Godino, Dario Martin; Corzo, Santiago Francisco; Ramajo, Damian Enrique; Costa, Antonella Lombardi; et al.; Heat transfer in a simulated spent fuel pool for different types of spent fuels; Brazilian Journal of Development; Brazilian Journal of Development; 9; 1-2023; 5004-50192525-8761CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.34117/bjdv9n1-343info:eu-repo/semantics/altIdentifier/url/https://ojs.brazilianjournals.com.br/ojs/index.php/BRJD/article/view/56708info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:54:37Zoai:ri.conicet.gov.ar:11336/226323instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:54:38.08CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Heat transfer in a simulated spent fuel pool for different types of spent fuels Transferência de calor em um pool simulado de combustível queimado para diferentes tipos de combustíveis queimados |
title |
Heat transfer in a simulated spent fuel pool for different types of spent fuels |
spellingShingle |
Heat transfer in a simulated spent fuel pool for different types of spent fuels de Faria, Fernando Pereira SPENT FUEL POOL OPENFOAM CFX |
title_short |
Heat transfer in a simulated spent fuel pool for different types of spent fuels |
title_full |
Heat transfer in a simulated spent fuel pool for different types of spent fuels |
title_fullStr |
Heat transfer in a simulated spent fuel pool for different types of spent fuels |
title_full_unstemmed |
Heat transfer in a simulated spent fuel pool for different types of spent fuels |
title_sort |
Heat transfer in a simulated spent fuel pool for different types of spent fuels |
dc.creator.none.fl_str_mv |
de Faria, Fernando Pereira Godino, Dario Martin Corzo, Santiago Francisco Ramajo, Damian Enrique Costa, Antonella Lombardi Pereira, Claubia |
author |
de Faria, Fernando Pereira |
author_facet |
de Faria, Fernando Pereira Godino, Dario Martin Corzo, Santiago Francisco Ramajo, Damian Enrique Costa, Antonella Lombardi Pereira, Claubia |
author_role |
author |
author2 |
Godino, Dario Martin Corzo, Santiago Francisco Ramajo, Damian Enrique Costa, Antonella Lombardi Pereira, Claubia |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
SPENT FUEL POOL OPENFOAM CFX |
topic |
SPENT FUEL POOL OPENFOAM CFX |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.3 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
Historically, the Spent Fuel Pool (SFP) of Angra II, from Brazil, has received standard spent fuel (SF) assemblies of uranium dioxide (UO2) discharged from Pressurized Water Reactors (PWR) of the Nuclear Power Plants (NPP) of Angra. However, in case of using Mixed Oxide (MOX) or thorium-based fuels at a proportion of 1/3 or 1/4 of the total of fuel assemblies in their PWRs as it has been occurring worldwide, it would require further thermal studies of wet storage of the new mixed SF generated. It includes the determination of the water boiling time (Tb) of the SFP in case of breakdown of its external cooling system (ECS). This work presents studies of Tb of a simulated SFP storing mixed SF discharged from PWRs. The types of mixed SF studied include MOX plus UO2, oxide of thorium/uranium (U-Th)O2 plus UO2, and oxide of thorium/transuranic (TRU-Th)O2 plus UO2. All the mixed SF was considered to contain 1/3 or 1/4 of either thorium-based fuels or reprocessed fuel. The simulations were implemented in CFX Ansys and OpenFOAM© codes. Tb from simulations with Ansys ranged from 4.05 h to 5.97 h, and from 3.45 h to 5.77 h from simulations with OpenFOAM©. Results show that, independent of the mixed loading pattern of the SFP, the water would reach the saturation temperature more rapidly when (TRU-Th)O2 was present. By contrast, when MOX was present, Tb was greater. Historicamente, o Pool de Combustível Irradiado (SFP) de Angra II, do Brasil, tem recebido montagens de combustível padrão gasto (SF) de dióxido de urânio (UO2) descarregado de Reatores de Água Pressurizada (PWR) das Usinas Nucleares (NPP) de Angra. Entretanto, no caso de utilização de combustíveis à base de óxido misto (MOX) ou tório na proporção de 1/3 ou 1/4 do total de conjuntos de combustível em suas PWRs como vem ocorrendo em todo o mundo, seriam necessários mais estudos térmicos de armazenamento úmido do novo SF misto gerado. Inclui a determinação do tempo de ebulição da água (Tb) do SFP em caso de quebra de seu sistema de resfriamento externo (ECS). Este trabalho apresenta estudos de Tb de um SFP simulado de armazenamento de SF misto descarregado de PWRs. Os tipos de SF mistos estudados incluem MOX mais UO2, óxido de tório/urânio (U-Th)O2 mais UO2, e óxido de tório/transurânico (TRUTh)O2 mais UO2. Todo o SF misto foi considerado como contendo 1/3 ou 1/4 de combustíveis à base de tório ou combustível reprocessado. As simulações foram implementadas nos códigos CFX Ansys e OpenFOAM©. Tb de simulações com Ansys variou de 4,05 h a 5,97 h, e de 3,45 h a 5,77 h de simulações com OpenFOAM©. Os resultados mostram que, independente do padrão de carga mista do SFP, a água alcançaria a temperatura de saturação mais rapidamente quando (TRU-Th)O2 estivesse presente. Em contraste, quando MOX estava presente, a Tb era maior. Fil: de Faria, Fernando Pereira. Departamento de Engenharia Nuclear; Brasil Fil: Godino, Dario Martin. Universidad Nacional de Rosario. Facultad de Ciencias Exactas Ingeniería y Agrimensura. Escuela de Ingeniería Mecánica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; Argentina Fil: Corzo, Santiago Francisco. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; Argentina Fil: Ramajo, Damian Enrique. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Centro de Investigaciones en Métodos Computacionales. Universidad Nacional del Litoral. Centro de Investigaciones en Métodos Computacionales; Argentina Fil: Costa, Antonella Lombardi. Departamento de Engenharia Nuclear; Brasil Fil: Pereira, Claubia. Departamento de Engenharia Nuclear; Brasil |
description |
Historically, the Spent Fuel Pool (SFP) of Angra II, from Brazil, has received standard spent fuel (SF) assemblies of uranium dioxide (UO2) discharged from Pressurized Water Reactors (PWR) of the Nuclear Power Plants (NPP) of Angra. However, in case of using Mixed Oxide (MOX) or thorium-based fuels at a proportion of 1/3 or 1/4 of the total of fuel assemblies in their PWRs as it has been occurring worldwide, it would require further thermal studies of wet storage of the new mixed SF generated. It includes the determination of the water boiling time (Tb) of the SFP in case of breakdown of its external cooling system (ECS). This work presents studies of Tb of a simulated SFP storing mixed SF discharged from PWRs. The types of mixed SF studied include MOX plus UO2, oxide of thorium/uranium (U-Th)O2 plus UO2, and oxide of thorium/transuranic (TRU-Th)O2 plus UO2. All the mixed SF was considered to contain 1/3 or 1/4 of either thorium-based fuels or reprocessed fuel. The simulations were implemented in CFX Ansys and OpenFOAM© codes. Tb from simulations with Ansys ranged from 4.05 h to 5.97 h, and from 3.45 h to 5.77 h from simulations with OpenFOAM©. Results show that, independent of the mixed loading pattern of the SFP, the water would reach the saturation temperature more rapidly when (TRU-Th)O2 was present. By contrast, when MOX was present, Tb was greater. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/226323 de Faria, Fernando Pereira ; Godino, Dario Martin; Corzo, Santiago Francisco; Ramajo, Damian Enrique; Costa, Antonella Lombardi; et al.; Heat transfer in a simulated spent fuel pool for different types of spent fuels; Brazilian Journal of Development; Brazilian Journal of Development; 9; 1-2023; 5004-5019 2525-8761 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/226323 |
identifier_str_mv |
de Faria, Fernando Pereira ; Godino, Dario Martin; Corzo, Santiago Francisco; Ramajo, Damian Enrique; Costa, Antonella Lombardi; et al.; Heat transfer in a simulated spent fuel pool for different types of spent fuels; Brazilian Journal of Development; Brazilian Journal of Development; 9; 1-2023; 5004-5019 2525-8761 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.34117/bjdv9n1-343 info:eu-repo/semantics/altIdentifier/url/https://ojs.brazilianjournals.com.br/ojs/index.php/BRJD/article/view/56708 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Brazilian Journal of Development |
publisher.none.fl_str_mv |
Brazilian Journal of Development |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842269297090494464 |
score |