Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking...

Autores
Vissio, Claudina; Mella, Armin; Amestica, Luis; Pol, Martin
Año de publicación
2020
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
The aim of this study was to demonstrate the noninferiority of a novel teat disinfectant based on copper and zinc (ZkinCu; Copper Andino, Santiago de Chile, Chile) compared with a previously proven glycolic acid active disinfectant (OceanBlu; DeLaval, Kansas City, MO) as a positive control, with respect to the incidence of new intramammary infections under natural challenge conditions on a commercial robotic dairy farm. This study was conducted in 6 robotic pens of approximately 60 milking cows each. The pens were randomly assigned to 1 of the 2 studied disinfectants. Throughout the 8 wk study, the same pre- and post-milking teat disinfectant was used in each pen. The same milking procedures were used in each robot throughout the study. Pre-milking hygiene consisted of applying the disinfectant (OceanBlu or ZkinCu) with the robotic arm. The same product was applied on the teats after milking. At the beginning of the study, all quarters of all study cows were sampled. In successive samplings (wk 2, 4, 6, and 8), composite milk samples were collected on farm to determine SCC. Once composite SCC results were available (2 d) and based on an SCC of ≥100,000 cells/mL, quarter milk samples underwent bacteriological culture. Clinical mastitis was identified by study personnel. Intramammary infection in biweekly quarter milk samples was determined based on composite SCC levels (≥100,000 cells/mL) and the presence of bacteria. A new IMI was defined as a quarter in which the organism isolated was not present in the previous bacteriological sample, or the previous composite SCC sample was <100,000 cells/mL. Clinical mastitis samples were also considered to be new IMI. The trial was designed as a positive control field trial, in which the objective was to show noninferiority of ZkinCu versus the control (OceanBlu). The overall crude incidences of new IMI for 2 wk at risk were 4.9 and 7.3% for the ZkinCu and OceanBlu groups, respectively. The predominant organisms recovered from quarters with new IMI were Streptococcus uberis, Corynebacterium spp., and coagulase-negative staphylococci in both the ZkinCu and OceanBlu groups. The risk of infection in the OceanBlu group was higher (β = 0.644; 95% confidence interval = 0.05–1.22). The interaction of treatment by week was not significant. The new IMI rate estimates (95% confidence interval) for ZkinCu and OceanBlu were 1.7% (0.8–2.5) and 3.2% (1.7–4.7), respectively. One novel aspect of this study is that it was one of the first commercial noninferiority trials to evaluate a new pre- and post-milking teat disinfectant in a dairy herd with an automatic milking system. The experimental teat disinfectant ZkinCu, evaluated in this field trial with naturally occurring IMI, showed noninferiority relative to the positive control for the prevention of new IMI. This study was conducted in a herd with an automatic milking system, and the results are applicable to herds with similar characteristics. Additional studies are needed to ensure reproducibility under different management conditions.
Fil: Vissio, Claudina. Universidad Nacional de Río Cuarto. Instituto para el Desarrollo Agroindustrial y de la Salud. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto para el Desarrollo Agroindustrial y de la Salud; Argentina
Fil: Mella, Armin. Universidad Austral de Chile; Chile
Fil: Amestica, Luis. R&d Copper Andino Sa; Chile
Fil: Pol, Martin. Lactodiagnóstico Sur SRL; Argentina
Materia
AUTOMATIC MILKING
INTRAMAMMARY INFECTION
NONINFERIORITY TRIAL
TEAT DISINFECTANT
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/136284

id CONICETDig_3071e43188fac0431ee5066765a85e37
oai_identifier_str oai:ri.conicet.gov.ar:11336/136284
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking systemVissio, ClaudinaMella, ArminAmestica, LuisPol, MartinAUTOMATIC MILKINGINTRAMAMMARY INFECTIONNONINFERIORITY TRIALTEAT DISINFECTANThttps://purl.org/becyt/ford/4.3https://purl.org/becyt/ford/4The aim of this study was to demonstrate the noninferiority of a novel teat disinfectant based on copper and zinc (ZkinCu; Copper Andino, Santiago de Chile, Chile) compared with a previously proven glycolic acid active disinfectant (OceanBlu; DeLaval, Kansas City, MO) as a positive control, with respect to the incidence of new intramammary infections under natural challenge conditions on a commercial robotic dairy farm. This study was conducted in 6 robotic pens of approximately 60 milking cows each. The pens were randomly assigned to 1 of the 2 studied disinfectants. Throughout the 8 wk study, the same pre- and post-milking teat disinfectant was used in each pen. The same milking procedures were used in each robot throughout the study. Pre-milking hygiene consisted of applying the disinfectant (OceanBlu or ZkinCu) with the robotic arm. The same product was applied on the teats after milking. At the beginning of the study, all quarters of all study cows were sampled. In successive samplings (wk 2, 4, 6, and 8), composite milk samples were collected on farm to determine SCC. Once composite SCC results were available (2 d) and based on an SCC of ≥100,000 cells/mL, quarter milk samples underwent bacteriological culture. Clinical mastitis was identified by study personnel. Intramammary infection in biweekly quarter milk samples was determined based on composite SCC levels (≥100,000 cells/mL) and the presence of bacteria. A new IMI was defined as a quarter in which the organism isolated was not present in the previous bacteriological sample, or the previous composite SCC sample was <100,000 cells/mL. Clinical mastitis samples were also considered to be new IMI. The trial was designed as a positive control field trial, in which the objective was to show noninferiority of ZkinCu versus the control (OceanBlu). The overall crude incidences of new IMI for 2 wk at risk were 4.9 and 7.3% for the ZkinCu and OceanBlu groups, respectively. The predominant organisms recovered from quarters with new IMI were Streptococcus uberis, Corynebacterium spp., and coagulase-negative staphylococci in both the ZkinCu and OceanBlu groups. The risk of infection in the OceanBlu group was higher (β = 0.644; 95% confidence interval = 0.05–1.22). The interaction of treatment by week was not significant. The new IMI rate estimates (95% confidence interval) for ZkinCu and OceanBlu were 1.7% (0.8–2.5) and 3.2% (1.7–4.7), respectively. One novel aspect of this study is that it was one of the first commercial noninferiority trials to evaluate a new pre- and post-milking teat disinfectant in a dairy herd with an automatic milking system. The experimental teat disinfectant ZkinCu, evaluated in this field trial with naturally occurring IMI, showed noninferiority relative to the positive control for the prevention of new IMI. This study was conducted in a herd with an automatic milking system, and the results are applicable to herds with similar characteristics. Additional studies are needed to ensure reproducibility under different management conditions.Fil: Vissio, Claudina. Universidad Nacional de Río Cuarto. Instituto para el Desarrollo Agroindustrial y de la Salud. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto para el Desarrollo Agroindustrial y de la Salud; ArgentinaFil: Mella, Armin. Universidad Austral de Chile; ChileFil: Amestica, Luis. R&d Copper Andino Sa; ChileFil: Pol, Martin. Lactodiagnóstico Sur SRL; ArgentinaAmerican Dairy Science Association2020-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/136284Vissio, Claudina; Mella, Armin; Amestica, Luis; Pol, Martin; Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system; American Dairy Science Association; Journal of Dairy Science; 103; 2; 2-2020; 1776-17840022-03021525-3198CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0022030219310951info:eu-repo/semantics/altIdentifier/doi/10.3168/jds.2018-16217info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T10:00:50Zoai:ri.conicet.gov.ar:11336/136284instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 10:00:50.363CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
title Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
spellingShingle Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
Vissio, Claudina
AUTOMATIC MILKING
INTRAMAMMARY INFECTION
NONINFERIORITY TRIAL
TEAT DISINFECTANT
title_short Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
title_full Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
title_fullStr Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
title_full_unstemmed Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
title_sort Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system
dc.creator.none.fl_str_mv Vissio, Claudina
Mella, Armin
Amestica, Luis
Pol, Martin
author Vissio, Claudina
author_facet Vissio, Claudina
Mella, Armin
Amestica, Luis
Pol, Martin
author_role author
author2 Mella, Armin
Amestica, Luis
Pol, Martin
author2_role author
author
author
dc.subject.none.fl_str_mv AUTOMATIC MILKING
INTRAMAMMARY INFECTION
NONINFERIORITY TRIAL
TEAT DISINFECTANT
topic AUTOMATIC MILKING
INTRAMAMMARY INFECTION
NONINFERIORITY TRIAL
TEAT DISINFECTANT
purl_subject.fl_str_mv https://purl.org/becyt/ford/4.3
https://purl.org/becyt/ford/4
dc.description.none.fl_txt_mv The aim of this study was to demonstrate the noninferiority of a novel teat disinfectant based on copper and zinc (ZkinCu; Copper Andino, Santiago de Chile, Chile) compared with a previously proven glycolic acid active disinfectant (OceanBlu; DeLaval, Kansas City, MO) as a positive control, with respect to the incidence of new intramammary infections under natural challenge conditions on a commercial robotic dairy farm. This study was conducted in 6 robotic pens of approximately 60 milking cows each. The pens were randomly assigned to 1 of the 2 studied disinfectants. Throughout the 8 wk study, the same pre- and post-milking teat disinfectant was used in each pen. The same milking procedures were used in each robot throughout the study. Pre-milking hygiene consisted of applying the disinfectant (OceanBlu or ZkinCu) with the robotic arm. The same product was applied on the teats after milking. At the beginning of the study, all quarters of all study cows were sampled. In successive samplings (wk 2, 4, 6, and 8), composite milk samples were collected on farm to determine SCC. Once composite SCC results were available (2 d) and based on an SCC of ≥100,000 cells/mL, quarter milk samples underwent bacteriological culture. Clinical mastitis was identified by study personnel. Intramammary infection in biweekly quarter milk samples was determined based on composite SCC levels (≥100,000 cells/mL) and the presence of bacteria. A new IMI was defined as a quarter in which the organism isolated was not present in the previous bacteriological sample, or the previous composite SCC sample was <100,000 cells/mL. Clinical mastitis samples were also considered to be new IMI. The trial was designed as a positive control field trial, in which the objective was to show noninferiority of ZkinCu versus the control (OceanBlu). The overall crude incidences of new IMI for 2 wk at risk were 4.9 and 7.3% for the ZkinCu and OceanBlu groups, respectively. The predominant organisms recovered from quarters with new IMI were Streptococcus uberis, Corynebacterium spp., and coagulase-negative staphylococci in both the ZkinCu and OceanBlu groups. The risk of infection in the OceanBlu group was higher (β = 0.644; 95% confidence interval = 0.05–1.22). The interaction of treatment by week was not significant. The new IMI rate estimates (95% confidence interval) for ZkinCu and OceanBlu were 1.7% (0.8–2.5) and 3.2% (1.7–4.7), respectively. One novel aspect of this study is that it was one of the first commercial noninferiority trials to evaluate a new pre- and post-milking teat disinfectant in a dairy herd with an automatic milking system. The experimental teat disinfectant ZkinCu, evaluated in this field trial with naturally occurring IMI, showed noninferiority relative to the positive control for the prevention of new IMI. This study was conducted in a herd with an automatic milking system, and the results are applicable to herds with similar characteristics. Additional studies are needed to ensure reproducibility under different management conditions.
Fil: Vissio, Claudina. Universidad Nacional de Río Cuarto. Instituto para el Desarrollo Agroindustrial y de la Salud. - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto para el Desarrollo Agroindustrial y de la Salud; Argentina
Fil: Mella, Armin. Universidad Austral de Chile; Chile
Fil: Amestica, Luis. R&d Copper Andino Sa; Chile
Fil: Pol, Martin. Lactodiagnóstico Sur SRL; Argentina
description The aim of this study was to demonstrate the noninferiority of a novel teat disinfectant based on copper and zinc (ZkinCu; Copper Andino, Santiago de Chile, Chile) compared with a previously proven glycolic acid active disinfectant (OceanBlu; DeLaval, Kansas City, MO) as a positive control, with respect to the incidence of new intramammary infections under natural challenge conditions on a commercial robotic dairy farm. This study was conducted in 6 robotic pens of approximately 60 milking cows each. The pens were randomly assigned to 1 of the 2 studied disinfectants. Throughout the 8 wk study, the same pre- and post-milking teat disinfectant was used in each pen. The same milking procedures were used in each robot throughout the study. Pre-milking hygiene consisted of applying the disinfectant (OceanBlu or ZkinCu) with the robotic arm. The same product was applied on the teats after milking. At the beginning of the study, all quarters of all study cows were sampled. In successive samplings (wk 2, 4, 6, and 8), composite milk samples were collected on farm to determine SCC. Once composite SCC results were available (2 d) and based on an SCC of ≥100,000 cells/mL, quarter milk samples underwent bacteriological culture. Clinical mastitis was identified by study personnel. Intramammary infection in biweekly quarter milk samples was determined based on composite SCC levels (≥100,000 cells/mL) and the presence of bacteria. A new IMI was defined as a quarter in which the organism isolated was not present in the previous bacteriological sample, or the previous composite SCC sample was <100,000 cells/mL. Clinical mastitis samples were also considered to be new IMI. The trial was designed as a positive control field trial, in which the objective was to show noninferiority of ZkinCu versus the control (OceanBlu). The overall crude incidences of new IMI for 2 wk at risk were 4.9 and 7.3% for the ZkinCu and OceanBlu groups, respectively. The predominant organisms recovered from quarters with new IMI were Streptococcus uberis, Corynebacterium spp., and coagulase-negative staphylococci in both the ZkinCu and OceanBlu groups. The risk of infection in the OceanBlu group was higher (β = 0.644; 95% confidence interval = 0.05–1.22). The interaction of treatment by week was not significant. The new IMI rate estimates (95% confidence interval) for ZkinCu and OceanBlu were 1.7% (0.8–2.5) and 3.2% (1.7–4.7), respectively. One novel aspect of this study is that it was one of the first commercial noninferiority trials to evaluate a new pre- and post-milking teat disinfectant in a dairy herd with an automatic milking system. The experimental teat disinfectant ZkinCu, evaluated in this field trial with naturally occurring IMI, showed noninferiority relative to the positive control for the prevention of new IMI. This study was conducted in a herd with an automatic milking system, and the results are applicable to herds with similar characteristics. Additional studies are needed to ensure reproducibility under different management conditions.
publishDate 2020
dc.date.none.fl_str_mv 2020-02
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/136284
Vissio, Claudina; Mella, Armin; Amestica, Luis; Pol, Martin; Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system; American Dairy Science Association; Journal of Dairy Science; 103; 2; 2-2020; 1776-1784
0022-0302
1525-3198
CONICET Digital
CONICET
url http://hdl.handle.net/11336/136284
identifier_str_mv Vissio, Claudina; Mella, Armin; Amestica, Luis; Pol, Martin; Noninferiority study evaluating the efficacy of a teat disinfectant containing copper and zinc for prevention of naturally occurring intramammary infections in an automatic milking system; American Dairy Science Association; Journal of Dairy Science; 103; 2; 2-2020; 1776-1784
0022-0302
1525-3198
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0022030219310951
info:eu-repo/semantics/altIdentifier/doi/10.3168/jds.2018-16217
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv American Dairy Science Association
publisher.none.fl_str_mv American Dairy Science Association
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842269661705535488
score 13.13397