Error propagation in open respirometric assays

Autores
Lobo, Cintia Cecilia; Bertola, Nora Cristina; Contreras, Edgardo Martin
Año de publicación
2014
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
This work deals with the calculation of the uncertainty of the exogenous respiration rate (Rex) and the total oxygen consumed (OCT) derived from a single open respirometric profile. Uncertainties were evaluated by applying a linear error propagation method. Results show that standard deviations (SD) of Rexand OCT depend not only on the SD of the dissolved oxygen (σC) and kLa (σkLa), but also on the SD of the derivative term (dC/dt) of the oxygen mass balance equation (σb). A Monte Carlo technique was employed to assess σb; a power law expression for the dependence of σb as a function of σC, the time window (tw) and the sampling rate (Δt) was proposed. The equations obtained in the present work are useful to calculate suitable conditions (e.g., biomass concentration, kLa) that minimize the coefficient of variation corresponding to Rexand OCT.
Fil: Lobo, Cintia Cecilia. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina
Fil: Bertola, Nora Cristina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina
Fil: Contreras, Edgardo Martin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones en Ciencia y Tecnología de Materiales. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones en Ciencia y Tecnología de Materiales; Argentina
Materia
RESPIROMETRY
ERROR PROPAGATION
RESPIRATION RATE
OXYGEN CONSUMPTION
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/32396

id CONICETDig_2f5342210f7879431bc008b9934acadf
oai_identifier_str oai:ri.conicet.gov.ar:11336/32396
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Error propagation in open respirometric assaysLobo, Cintia CeciliaBertola, Nora CristinaContreras, Edgardo MartinRESPIROMETRYERROR PROPAGATIONRESPIRATION RATEOXYGEN CONSUMPTIONhttps://purl.org/becyt/ford/2.4https://purl.org/becyt/ford/2This work deals with the calculation of the uncertainty of the exogenous respiration rate (Rex) and the total oxygen consumed (OCT) derived from a single open respirometric profile. Uncertainties were evaluated by applying a linear error propagation method. Results show that standard deviations (SD) of Rexand OCT depend not only on the SD of the dissolved oxygen (σC) and kLa (σkLa), but also on the SD of the derivative term (dC/dt) of the oxygen mass balance equation (σb). A Monte Carlo technique was employed to assess σb; a power law expression for the dependence of σb as a function of σC, the time window (tw) and the sampling rate (Δt) was proposed. The equations obtained in the present work are useful to calculate suitable conditions (e.g., biomass concentration, kLa) that minimize the coefficient of variation corresponding to Rexand OCT.Fil: Lobo, Cintia Cecilia. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; ArgentinaFil: Bertola, Nora Cristina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; ArgentinaFil: Contreras, Edgardo Martin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones en Ciencia y Tecnología de Materiales. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones en Ciencia y Tecnología de Materiales; ArgentinaBrazilian Society of Chemical Engineering2014-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/32396Contreras, Edgardo Martin; Bertola, Nora Cristina; Lobo, Cintia Cecilia; Error propagation in open respirometric assays; Brazilian Society of Chemical Engineering; Brazilian Journal of Chemical Engineering; 31; 02; 4-2014; 303-3120104-66321678-4383CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1590/0104-6632.20140312s00002659info:eu-repo/semantics/altIdentifier/url/http://ref.scielo.org/xtdv84info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:47:56Zoai:ri.conicet.gov.ar:11336/32396instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:47:56.461CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Error propagation in open respirometric assays
title Error propagation in open respirometric assays
spellingShingle Error propagation in open respirometric assays
Lobo, Cintia Cecilia
RESPIROMETRY
ERROR PROPAGATION
RESPIRATION RATE
OXYGEN CONSUMPTION
title_short Error propagation in open respirometric assays
title_full Error propagation in open respirometric assays
title_fullStr Error propagation in open respirometric assays
title_full_unstemmed Error propagation in open respirometric assays
title_sort Error propagation in open respirometric assays
dc.creator.none.fl_str_mv Lobo, Cintia Cecilia
Bertola, Nora Cristina
Contreras, Edgardo Martin
author Lobo, Cintia Cecilia
author_facet Lobo, Cintia Cecilia
Bertola, Nora Cristina
Contreras, Edgardo Martin
author_role author
author2 Bertola, Nora Cristina
Contreras, Edgardo Martin
author2_role author
author
dc.subject.none.fl_str_mv RESPIROMETRY
ERROR PROPAGATION
RESPIRATION RATE
OXYGEN CONSUMPTION
topic RESPIROMETRY
ERROR PROPAGATION
RESPIRATION RATE
OXYGEN CONSUMPTION
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.4
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv This work deals with the calculation of the uncertainty of the exogenous respiration rate (Rex) and the total oxygen consumed (OCT) derived from a single open respirometric profile. Uncertainties were evaluated by applying a linear error propagation method. Results show that standard deviations (SD) of Rexand OCT depend not only on the SD of the dissolved oxygen (σC) and kLa (σkLa), but also on the SD of the derivative term (dC/dt) of the oxygen mass balance equation (σb). A Monte Carlo technique was employed to assess σb; a power law expression for the dependence of σb as a function of σC, the time window (tw) and the sampling rate (Δt) was proposed. The equations obtained in the present work are useful to calculate suitable conditions (e.g., biomass concentration, kLa) that minimize the coefficient of variation corresponding to Rexand OCT.
Fil: Lobo, Cintia Cecilia. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina
Fil: Bertola, Nora Cristina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina
Fil: Contreras, Edgardo Martin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones en Ciencia y Tecnología de Materiales. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones en Ciencia y Tecnología de Materiales; Argentina
description This work deals with the calculation of the uncertainty of the exogenous respiration rate (Rex) and the total oxygen consumed (OCT) derived from a single open respirometric profile. Uncertainties were evaluated by applying a linear error propagation method. Results show that standard deviations (SD) of Rexand OCT depend not only on the SD of the dissolved oxygen (σC) and kLa (σkLa), but also on the SD of the derivative term (dC/dt) of the oxygen mass balance equation (σb). A Monte Carlo technique was employed to assess σb; a power law expression for the dependence of σb as a function of σC, the time window (tw) and the sampling rate (Δt) was proposed. The equations obtained in the present work are useful to calculate suitable conditions (e.g., biomass concentration, kLa) that minimize the coefficient of variation corresponding to Rexand OCT.
publishDate 2014
dc.date.none.fl_str_mv 2014-04
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/32396
Contreras, Edgardo Martin; Bertola, Nora Cristina; Lobo, Cintia Cecilia; Error propagation in open respirometric assays; Brazilian Society of Chemical Engineering; Brazilian Journal of Chemical Engineering; 31; 02; 4-2014; 303-312
0104-6632
1678-4383
CONICET Digital
CONICET
url http://hdl.handle.net/11336/32396
identifier_str_mv Contreras, Edgardo Martin; Bertola, Nora Cristina; Lobo, Cintia Cecilia; Error propagation in open respirometric assays; Brazilian Society of Chemical Engineering; Brazilian Journal of Chemical Engineering; 31; 02; 4-2014; 303-312
0104-6632
1678-4383
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1590/0104-6632.20140312s00002659
info:eu-repo/semantics/altIdentifier/url/http://ref.scielo.org/xtdv84
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Brazilian Society of Chemical Engineering
publisher.none.fl_str_mv Brazilian Society of Chemical Engineering
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614524208939008
score 13.070432