Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
- Autores
- Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; G. Nieubourg; Duffó, Gustavo Sergio; Bataillon, C.
- Año de publicación
- 2014
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods.
Fil: Kursten, B.. SCK•CEN; Bélgica
Fil: Druyts, F.. SCK•CEN; Bélgica
Fil: Areias, L.. SCK•CEN; Bélgica
Fil: Ingelgem, Y. van. Vrije Unviversiteit Brussel; Bélgica
Fil: De Wilde, D.. Vrije Unviversiteit Brussel; Bélgica
Fil: G. Nieubourg. Vrije Unviversiteit Brussel; Bélgica
Fil: Duffó, Gustavo Sergio. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Unidad de Actividad de Materiales (CAC); Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Bataillon, C.. Commissariat à l'Énergie Atomique. Laboratoire d’Etude de la Corrosion Aqueuse; Francia - Materia
-
Uniform Corrosion
Passive
Concrete
Steel - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/33799
Ver los metadatos del registro completo
id |
CONICETDig_23b77f36b812dd7bcd3b170c508eea49 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/33799 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete bufferKursten, B.Druyts, F.Areias, L.Ingelgem, Y. vanDe Wilde, D.G. NieubourgDuffó, Gustavo SergioBataillon, C.Uniform CorrosionPassiveConcreteSteelhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods.Fil: Kursten, B.. SCK•CEN; BélgicaFil: Druyts, F.. SCK•CEN; BélgicaFil: Areias, L.. SCK•CEN; BélgicaFil: Ingelgem, Y. van. Vrije Unviversiteit Brussel; BélgicaFil: De Wilde, D.. Vrije Unviversiteit Brussel; BélgicaFil: G. Nieubourg. Vrije Unviversiteit Brussel; BélgicaFil: Duffó, Gustavo Sergio. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Unidad de Actividad de Materiales (CAC); Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Bataillon, C.. Commissariat à l'Énergie Atomique. Laboratoire d’Etude de la Corrosion Aqueuse; FranciaTaylor & Francis2014-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/33799Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; et al.; Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer; Taylor & Francis; Corrosion Engineering, Science And Technology; 49; 6; 7-2014; 485-4911478-422XCONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.tandfonline.com/doi/abs/10.1179/1743278214Y.0000000216info:eu-repo/semantics/altIdentifier/doi/10.1179/1743278214Y.0000000216info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-17T11:38:49Zoai:ri.conicet.gov.ar:11336/33799instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-17 11:38:49.664CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer |
title |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer |
spellingShingle |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer Kursten, B. Uniform Corrosion Passive Concrete Steel |
title_short |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer |
title_full |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer |
title_fullStr |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer |
title_full_unstemmed |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer |
title_sort |
Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer |
dc.creator.none.fl_str_mv |
Kursten, B. Druyts, F. Areias, L. Ingelgem, Y. van De Wilde, D. G. Nieubourg Duffó, Gustavo Sergio Bataillon, C. |
author |
Kursten, B. |
author_facet |
Kursten, B. Druyts, F. Areias, L. Ingelgem, Y. van De Wilde, D. G. Nieubourg Duffó, Gustavo Sergio Bataillon, C. |
author_role |
author |
author2 |
Druyts, F. Areias, L. Ingelgem, Y. van De Wilde, D. G. Nieubourg Duffó, Gustavo Sergio Bataillon, C. |
author2_role |
author author author author author author author |
dc.subject.none.fl_str_mv |
Uniform Corrosion Passive Concrete Steel |
topic |
Uniform Corrosion Passive Concrete Steel |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods. Fil: Kursten, B.. SCK•CEN; Bélgica Fil: Druyts, F.. SCK•CEN; Bélgica Fil: Areias, L.. SCK•CEN; Bélgica Fil: Ingelgem, Y. van. Vrije Unviversiteit Brussel; Bélgica Fil: De Wilde, D.. Vrije Unviversiteit Brussel; Bélgica Fil: G. Nieubourg. Vrije Unviversiteit Brussel; Bélgica Fil: Duffó, Gustavo Sergio. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Unidad de Actividad de Materiales (CAC); Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Bataillon, C.. Commissariat à l'Énergie Atomique. Laboratoire d’Etude de la Corrosion Aqueuse; Francia |
description |
The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-07 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/33799 Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; et al.; Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer; Taylor & Francis; Corrosion Engineering, Science And Technology; 49; 6; 7-2014; 485-491 1478-422X CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/33799 |
identifier_str_mv |
Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; et al.; Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer; Taylor & Francis; Corrosion Engineering, Science And Technology; 49; 6; 7-2014; 485-491 1478-422X CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://www.tandfonline.com/doi/abs/10.1179/1743278214Y.0000000216 info:eu-repo/semantics/altIdentifier/doi/10.1179/1743278214Y.0000000216 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Taylor & Francis |
publisher.none.fl_str_mv |
Taylor & Francis |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1843606745336774656 |
score |
13.001348 |