Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer

Autores
Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; G. Nieubourg; Duffó, Gustavo Sergio; Bataillon, C.
Año de publicación
2014
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods.
Fil: Kursten, B.. SCK•CEN; Bélgica
Fil: Druyts, F.. SCK•CEN; Bélgica
Fil: Areias, L.. SCK•CEN; Bélgica
Fil: Ingelgem, Y. van. Vrije Unviversiteit Brussel; Bélgica
Fil: De Wilde, D.. Vrije Unviversiteit Brussel; Bélgica
Fil: G. Nieubourg. Vrije Unviversiteit Brussel; Bélgica
Fil: Duffó, Gustavo Sergio. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Unidad de Actividad de Materiales (CAC); Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Bataillon, C.. Commissariat à l'Énergie Atomique. Laboratoire d’Etude de la Corrosion Aqueuse; Francia
Materia
Uniform Corrosion
Passive
Concrete
Steel
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/33799

id CONICETDig_23b77f36b812dd7bcd3b170c508eea49
oai_identifier_str oai:ri.conicet.gov.ar:11336/33799
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete bufferKursten, B.Druyts, F.Areias, L.Ingelgem, Y. vanDe Wilde, D.G. NieubourgDuffó, Gustavo SergioBataillon, C.Uniform CorrosionPassiveConcreteSteelhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods.Fil: Kursten, B.. SCK•CEN; BélgicaFil: Druyts, F.. SCK•CEN; BélgicaFil: Areias, L.. SCK•CEN; BélgicaFil: Ingelgem, Y. van. Vrije Unviversiteit Brussel; BélgicaFil: De Wilde, D.. Vrije Unviversiteit Brussel; BélgicaFil: G. Nieubourg. Vrije Unviversiteit Brussel; BélgicaFil: Duffó, Gustavo Sergio. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Unidad de Actividad de Materiales (CAC); Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Bataillon, C.. Commissariat à l'Énergie Atomique. Laboratoire d’Etude de la Corrosion Aqueuse; FranciaTaylor & Francis2014-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/33799Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; et al.; Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer; Taylor & Francis; Corrosion Engineering, Science And Technology; 49; 6; 7-2014; 485-4911478-422XCONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.tandfonline.com/doi/abs/10.1179/1743278214Y.0000000216info:eu-repo/semantics/altIdentifier/doi/10.1179/1743278214Y.0000000216info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-17T11:38:49Zoai:ri.conicet.gov.ar:11336/33799instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-17 11:38:49.664CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
title Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
spellingShingle Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
Kursten, B.
Uniform Corrosion
Passive
Concrete
Steel
title_short Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
title_full Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
title_fullStr Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
title_full_unstemmed Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
title_sort Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer
dc.creator.none.fl_str_mv Kursten, B.
Druyts, F.
Areias, L.
Ingelgem, Y. van
De Wilde, D.
G. Nieubourg
Duffó, Gustavo Sergio
Bataillon, C.
author Kursten, B.
author_facet Kursten, B.
Druyts, F.
Areias, L.
Ingelgem, Y. van
De Wilde, D.
G. Nieubourg
Duffó, Gustavo Sergio
Bataillon, C.
author_role author
author2 Druyts, F.
Areias, L.
Ingelgem, Y. van
De Wilde, D.
G. Nieubourg
Duffó, Gustavo Sergio
Bataillon, C.
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Uniform Corrosion
Passive
Concrete
Steel
topic Uniform Corrosion
Passive
Concrete
Steel
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods.
Fil: Kursten, B.. SCK•CEN; Bélgica
Fil: Druyts, F.. SCK•CEN; Bélgica
Fil: Areias, L.. SCK•CEN; Bélgica
Fil: Ingelgem, Y. van. Vrije Unviversiteit Brussel; Bélgica
Fil: De Wilde, D.. Vrije Unviversiteit Brussel; Bélgica
Fil: G. Nieubourg. Vrije Unviversiteit Brussel; Bélgica
Fil: Duffó, Gustavo Sergio. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Unidad de Actividad de Materiales (CAC); Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Bataillon, C.. Commissariat à l'Énergie Atomique. Laboratoire d’Etude de la Corrosion Aqueuse; Francia
description The supercontainer (SC) is the reference concept for the postconditioning of vitrified high level radioactive waste and spent fuel in Belgium. It is designed with a concrete buffer completely surrounding a carbon steel overpack. A half-scale (HST-2) experiment was set up to measure the instantaneous uniform corrosion rate, representative of the initial oxic phase, in situ. The test setup has the same diameter as a full size SC, but it is limited in height to approximately half of a real SC. The corrosion rate of carbon steel is measured in four ways: weight loss measurements (carbon steel coupons), corrosion sensor based on linear polarisation resistance, corrosion sensor based on multisine electrochemical impedance spectroscopy and corrosion sensor based on single sine electrochemical impedance spectroscopy coupled to a unique analytical method. This paper presents the preliminary results of the corrosion rates measured with these independent methods.
publishDate 2014
dc.date.none.fl_str_mv 2014-07
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/33799
Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; et al.; Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer; Taylor & Francis; Corrosion Engineering, Science And Technology; 49; 6; 7-2014; 485-491
1478-422X
CONICET Digital
CONICET
url http://hdl.handle.net/11336/33799
identifier_str_mv Kursten, B.; Druyts, F.; Areias, L.; Ingelgem, Y. van; De Wilde, D.; et al.; Preliminary results of corrosion monitoring studies of carbon steel overpack exposed to supercontainer concrete buffer; Taylor & Francis; Corrosion Engineering, Science And Technology; 49; 6; 7-2014; 485-491
1478-422X
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://www.tandfonline.com/doi/abs/10.1179/1743278214Y.0000000216
info:eu-repo/semantics/altIdentifier/doi/10.1179/1743278214Y.0000000216
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Taylor & Francis
publisher.none.fl_str_mv Taylor & Francis
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1843606745336774656
score 13.001348