Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement
- Autores
- Vazquez, D.R.; Villagrán Zaccardi, Yury Andrés; Zega, Claudio Javier; Sosa, M. E.; Duffó, Gustavo Sergio
- Año de publicación
- 2015
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- For the development of an intermediate radioactive waste repository, two different types of reinforced concrete were analyzed in terms of durability: one made with ordinary portland cement and the other one made with pozzolanic cement. The values for compressive strength, sorptivity and air permeability demonstrate that the formulations are compatible with the required application. The corrosion rate of rebar up to about 300 days of monitoring and obtained with sensors is below the threshold value required for this type of facilities, except when temperatures are high. The value for the same parameter monitored by the galvanostatic pulse technique using superficial counter electrode and guard electrode is always lower than the threshold value. Additionally, when applying the galvanostatic pulse technique using embedded electrodes, this parameter is comparable to the guard electrode method only when the polarization resistance is calculated through non-linear fitting.
Fil: Vazquez, D.R.. Comisión Nacional de Energía Atómica; Argentina. Universidad Nacional de San Martín. Instituto Sabato; Argentina
Fil: Villagrán Zaccardi, Yury Andrés. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Zega, Claudio Javier. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Sosa, M. E.. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina
Fil: Duffó, Gustavo Sergio. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Instituto Sabato; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina - Materia
-
RADIACTIVE WASTE
CORROSION
REINFORCED CONCRETE DURABILITY - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/112734
Ver los metadatos del registro completo
id |
CONICETDig_1ba6937a1e551ab3bbb594158ff2db55 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/112734 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cementVazquez, D.R.Villagrán Zaccardi, Yury AndrésZega, Claudio JavierSosa, M. E.Duffó, Gustavo SergioRADIACTIVE WASTECORROSIONREINFORCED CONCRETE DURABILITYhttps://purl.org/becyt/ford/2.5https://purl.org/becyt/ford/2For the development of an intermediate radioactive waste repository, two different types of reinforced concrete were analyzed in terms of durability: one made with ordinary portland cement and the other one made with pozzolanic cement. The values for compressive strength, sorptivity and air permeability demonstrate that the formulations are compatible with the required application. The corrosion rate of rebar up to about 300 days of monitoring and obtained with sensors is below the threshold value required for this type of facilities, except when temperatures are high. The value for the same parameter monitored by the galvanostatic pulse technique using superficial counter electrode and guard electrode is always lower than the threshold value. Additionally, when applying the galvanostatic pulse technique using embedded electrodes, this parameter is comparable to the guard electrode method only when the polarization resistance is calculated through non-linear fitting.Fil: Vazquez, D.R.. Comisión Nacional de Energía Atómica; Argentina. Universidad Nacional de San Martín. Instituto Sabato; ArgentinaFil: Villagrán Zaccardi, Yury Andrés. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Zega, Claudio Javier. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Sosa, M. E.. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; ArgentinaFil: Duffó, Gustavo Sergio. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Instituto Sabato; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; ArgentinaElsevier2015-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/112734Vazquez, D.R. ; Villagrán Zaccardi, Yury Andrés; Zega, Claudio Javier; Sosa, M. E.; Duffó, Gustavo Sergio; Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement; Elsevier; Procedia Materials Science; 8; 8-2015; 73-812211-8128CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S2211812815000516info:eu-repo/semantics/altIdentifier/doi/10.1016/j.mspro.2015.04.050info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:42:49Zoai:ri.conicet.gov.ar:11336/112734instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:42:49.782CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement |
title |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement |
spellingShingle |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement Vazquez, D.R. RADIACTIVE WASTE CORROSION REINFORCED CONCRETE DURABILITY |
title_short |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement |
title_full |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement |
title_fullStr |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement |
title_full_unstemmed |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement |
title_sort |
Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement |
dc.creator.none.fl_str_mv |
Vazquez, D.R. Villagrán Zaccardi, Yury Andrés Zega, Claudio Javier Sosa, M. E. Duffó, Gustavo Sergio |
author |
Vazquez, D.R. |
author_facet |
Vazquez, D.R. Villagrán Zaccardi, Yury Andrés Zega, Claudio Javier Sosa, M. E. Duffó, Gustavo Sergio |
author_role |
author |
author2 |
Villagrán Zaccardi, Yury Andrés Zega, Claudio Javier Sosa, M. E. Duffó, Gustavo Sergio |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
RADIACTIVE WASTE CORROSION REINFORCED CONCRETE DURABILITY |
topic |
RADIACTIVE WASTE CORROSION REINFORCED CONCRETE DURABILITY |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.5 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
For the development of an intermediate radioactive waste repository, two different types of reinforced concrete were analyzed in terms of durability: one made with ordinary portland cement and the other one made with pozzolanic cement. The values for compressive strength, sorptivity and air permeability demonstrate that the formulations are compatible with the required application. The corrosion rate of rebar up to about 300 days of monitoring and obtained with sensors is below the threshold value required for this type of facilities, except when temperatures are high. The value for the same parameter monitored by the galvanostatic pulse technique using superficial counter electrode and guard electrode is always lower than the threshold value. Additionally, when applying the galvanostatic pulse technique using embedded electrodes, this parameter is comparable to the guard electrode method only when the polarization resistance is calculated through non-linear fitting. Fil: Vazquez, D.R.. Comisión Nacional de Energía Atómica; Argentina. Universidad Nacional de San Martín. Instituto Sabato; Argentina Fil: Villagrán Zaccardi, Yury Andrés. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Zega, Claudio Javier. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Sosa, M. E.. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina Fil: Duffó, Gustavo Sergio. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Instituto Sabato; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica; Argentina |
description |
For the development of an intermediate radioactive waste repository, two different types of reinforced concrete were analyzed in terms of durability: one made with ordinary portland cement and the other one made with pozzolanic cement. The values for compressive strength, sorptivity and air permeability demonstrate that the formulations are compatible with the required application. The corrosion rate of rebar up to about 300 days of monitoring and obtained with sensors is below the threshold value required for this type of facilities, except when temperatures are high. The value for the same parameter monitored by the galvanostatic pulse technique using superficial counter electrode and guard electrode is always lower than the threshold value. Additionally, when applying the galvanostatic pulse technique using embedded electrodes, this parameter is comparable to the guard electrode method only when the polarization resistance is calculated through non-linear fitting. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-08 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/112734 Vazquez, D.R. ; Villagrán Zaccardi, Yury Andrés; Zega, Claudio Javier; Sosa, M. E.; Duffó, Gustavo Sergio; Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement; Elsevier; Procedia Materials Science; 8; 8-2015; 73-81 2211-8128 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/112734 |
identifier_str_mv |
Vazquez, D.R. ; Villagrán Zaccardi, Yury Andrés; Zega, Claudio Javier; Sosa, M. E.; Duffó, Gustavo Sergio; Implementation of different technics for the monitoring of reinforced concretes corrosion applied to rebar embedded in concretes with ordinary and pozzolanic Portland cement; Elsevier; Procedia Materials Science; 8; 8-2015; 73-81 2211-8128 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S2211812815000516 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.mspro.2015.04.050 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844614461775675392 |
score |
13.070432 |