Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil

Autores
Scherger, Leonardo Ezequiel; Zanello, Victoria; Lexow, Claudio
Año de publicación
2020
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
The aim of this work is to compare the use of the inverse solution approach in the estimation of soil hydraulic properties with traditional tension disk infiltrometer (TDI) data analysis, field retention data and commonly used pedotransfer functions (PTFs). Field data were collected in an experimental plot located at Bahía Blanca, Argentina. Field infiltration under saturated conditions was measured by the inverse auger hole method and infiltration under unsaturated condi-tions were carried out with TDI. Field retention data (θ(h)) were also collected periodically. The HYDRUS 2D/3D software was used to optimize soil hydraulic parameters by inverse solution according to TDI data. The saturated hydraulic con-ductivity measured by inverse auger hole method (5.53 cm.h-1) and calculated by Wooding analytical approach (5.35 cm.h-1) and inverse numerical simulations (5.36 cm.h-1) showed very close values. According to macroporosity esti-mates infiltrated water is mainly conducted through soils micro and mesopores. Macropores only channeled 15.9% of total infiltrated flow. Soil water retention curves (SWRC) predicted by PTFs did not represented correctly field retention data. The best adjustment between water content at specific pressure heads predicted by SWRCs and field measured water content was reached by the TDI inverse solution approach (RMSE: 0.050 cm3.cm-3). The inverse solution approach probed to be a simple and practical method to obtain an accurate estimate of both, SWRC and hydraulic conductivity curve.
O objetivo deste trabalho é comparar o uso da solução inversa na estimativa das propriedades hidráulicas do solo com a análise tradicional de dados por infiltrômetro de disco de tensão (IDT), dados de retenção em campo e funções de pedotransferência (FPTs) comumente usadas. Os dados de campo foram coletados em uma parcela experimental lo-calizada em Bahía Blanca, Argentina. A infiltração no campo sob condições saturadas foi medida pelo método do furo inverso e a infiltração sob condições insaturadas foi realizada com IDT. Os dados de retenção de campo (θ(h)) também foram coletados periodicamente. O software HYDRUS 2D/3D foi utilizado para otimizar os parâmetros hidráulicos do solo por solução inversa, de acordo com os dados do IDT. A condutividade hidráulica saturada medida pelo método do furo inverso (5.53 cm.h-1) e calculada pela abordagem analítica de Wooding (5.35 cm.h-1) e simulações numéricas inversas (5.36 cm.h-1) mostraram valores muito próximos. Segundo estimativas de macroporosidade, a água infiltrada é conduzida principalmente através de microporos e mesoporos do solo. Os macroporos canalizaram apenas 15.9% do fluxo total infiltrado. As curvas de retenção previstas pelos FPTs não representaram corretamente os dados de retenção em campo. O melhor ajuste entre o teor de água nas tensões específicas previstas pelas curvas de retenção e o teor de água medido no campo foi alcançado pela abordagem de solução inversade IDT (RMSE: 0.050 cm3.cm-3). A abordagem de solução inversa demonstrou ser um método simples e prático para obter uma estimativa precisa de curvas de re-tenção e de condutividade hidráulica.
Fil: Scherger, Leonardo Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca; Argentina. Universidad Nacional del Sur. Departamento de Geología; Argentina
Fil: Zanello, Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca; Argentina. Comisión de Investigaciones Científicas de la Provincia de Buenos Aires. Centro de Geología Aplicada, Agua y Medio Ambiente; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas; Argentina
Fil: Lexow, Claudio. Universidad Nacional del Sur. Departamento de Geología; Argentina
Materia
TENSION DISK INFILTROMETER
INVERSE SOLUTION
SOIL WATER RETENTION CURVE
HYDRUS 2D/3D
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/132704

id CONICETDig_0313d6cb77be52d22d34d58fd480a1d6
oai_identifier_str oai:ri.conicet.gov.ar:11336/132704
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soilComparação da abordagem de modelagem inversa e métodos tradicionais para estimar as propriedades hidráulicas insaturadas em solo franco arenosoScherger, Leonardo EzequielZanello, VictoriaLexow, ClaudioTENSION DISK INFILTROMETERINVERSE SOLUTIONSOIL WATER RETENTION CURVEHYDRUS 2D/3Dhttps://purl.org/becyt/ford/1.5https://purl.org/becyt/ford/1The aim of this work is to compare the use of the inverse solution approach in the estimation of soil hydraulic properties with traditional tension disk infiltrometer (TDI) data analysis, field retention data and commonly used pedotransfer functions (PTFs). Field data were collected in an experimental plot located at Bahía Blanca, Argentina. Field infiltration under saturated conditions was measured by the inverse auger hole method and infiltration under unsaturated condi-tions were carried out with TDI. Field retention data (θ(h)) were also collected periodically. The HYDRUS 2D/3D software was used to optimize soil hydraulic parameters by inverse solution according to TDI data. The saturated hydraulic con-ductivity measured by inverse auger hole method (5.53 cm.h-1) and calculated by Wooding analytical approach (5.35 cm.h-1) and inverse numerical simulations (5.36 cm.h-1) showed very close values. According to macroporosity esti-mates infiltrated water is mainly conducted through soils micro and mesopores. Macropores only channeled 15.9% of total infiltrated flow. Soil water retention curves (SWRC) predicted by PTFs did not represented correctly field retention data. The best adjustment between water content at specific pressure heads predicted by SWRCs and field measured water content was reached by the TDI inverse solution approach (RMSE: 0.050 cm3.cm-3). The inverse solution approach probed to be a simple and practical method to obtain an accurate estimate of both, SWRC and hydraulic conductivity curve.O objetivo deste trabalho é comparar o uso da solução inversa na estimativa das propriedades hidráulicas do solo com a análise tradicional de dados por infiltrômetro de disco de tensão (IDT), dados de retenção em campo e funções de pedotransferência (FPTs) comumente usadas. Os dados de campo foram coletados em uma parcela experimental lo-calizada em Bahía Blanca, Argentina. A infiltração no campo sob condições saturadas foi medida pelo método do furo inverso e a infiltração sob condições insaturadas foi realizada com IDT. Os dados de retenção de campo (θ(h)) também foram coletados periodicamente. O software HYDRUS 2D/3D foi utilizado para otimizar os parâmetros hidráulicos do solo por solução inversa, de acordo com os dados do IDT. A condutividade hidráulica saturada medida pelo método do furo inverso (5.53 cm.h-1) e calculada pela abordagem analítica de Wooding (5.35 cm.h-1) e simulações numéricas inversas (5.36 cm.h-1) mostraram valores muito próximos. Segundo estimativas de macroporosidade, a água infiltrada é conduzida principalmente através de microporos e mesoporos do solo. Os macroporos canalizaram apenas 15.9% do fluxo total infiltrado. As curvas de retenção previstas pelos FPTs não representaram corretamente os dados de retenção em campo. O melhor ajuste entre o teor de água nas tensões específicas previstas pelas curvas de retenção e o teor de água medido no campo foi alcançado pela abordagem de solução inversade IDT (RMSE: 0.050 cm3.cm-3). A abordagem de solução inversa demonstrou ser um método simples e prático para obter uma estimativa precisa de curvas de re-tenção e de condutividade hidráulica.Fil: Scherger, Leonardo Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca; Argentina. Universidad Nacional del Sur. Departamento de Geología; ArgentinaFil: Zanello, Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca; Argentina. Comisión de Investigaciones Científicas de la Provincia de Buenos Aires. Centro de Geología Aplicada, Agua y Medio Ambiente; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas; ArgentinaFil: Lexow, Claudio. Universidad Nacional del Sur. Departamento de Geología; ArgentinaAssociação Brasileira de Águas Subterrânea2020-09-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/132704Scherger, Leonardo Ezequiel; Zanello, Victoria; Lexow, Claudio; Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil; Associação Brasileira de Águas Subterrânea; Revista Aguas Subterraneas; 34; 3; 8-9-2020; 310-3240101-70042179-9784CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://aguassubterraneas.abas.org/asubterraneas/article/view/29929info:eu-repo/semantics/altIdentifier/doi/10.14295/ras.v34i3.29929info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:37:24Zoai:ri.conicet.gov.ar:11336/132704instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:37:24.52CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
Comparação da abordagem de modelagem inversa e métodos tradicionais para estimar as propriedades hidráulicas insaturadas em solo franco arenoso
title Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
spellingShingle Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
Scherger, Leonardo Ezequiel
TENSION DISK INFILTROMETER
INVERSE SOLUTION
SOIL WATER RETENTION CURVE
HYDRUS 2D/3D
title_short Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
title_full Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
title_fullStr Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
title_full_unstemmed Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
title_sort Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil
dc.creator.none.fl_str_mv Scherger, Leonardo Ezequiel
Zanello, Victoria
Lexow, Claudio
author Scherger, Leonardo Ezequiel
author_facet Scherger, Leonardo Ezequiel
Zanello, Victoria
Lexow, Claudio
author_role author
author2 Zanello, Victoria
Lexow, Claudio
author2_role author
author
dc.subject.none.fl_str_mv TENSION DISK INFILTROMETER
INVERSE SOLUTION
SOIL WATER RETENTION CURVE
HYDRUS 2D/3D
topic TENSION DISK INFILTROMETER
INVERSE SOLUTION
SOIL WATER RETENTION CURVE
HYDRUS 2D/3D
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.5
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv The aim of this work is to compare the use of the inverse solution approach in the estimation of soil hydraulic properties with traditional tension disk infiltrometer (TDI) data analysis, field retention data and commonly used pedotransfer functions (PTFs). Field data were collected in an experimental plot located at Bahía Blanca, Argentina. Field infiltration under saturated conditions was measured by the inverse auger hole method and infiltration under unsaturated condi-tions were carried out with TDI. Field retention data (θ(h)) were also collected periodically. The HYDRUS 2D/3D software was used to optimize soil hydraulic parameters by inverse solution according to TDI data. The saturated hydraulic con-ductivity measured by inverse auger hole method (5.53 cm.h-1) and calculated by Wooding analytical approach (5.35 cm.h-1) and inverse numerical simulations (5.36 cm.h-1) showed very close values. According to macroporosity esti-mates infiltrated water is mainly conducted through soils micro and mesopores. Macropores only channeled 15.9% of total infiltrated flow. Soil water retention curves (SWRC) predicted by PTFs did not represented correctly field retention data. The best adjustment between water content at specific pressure heads predicted by SWRCs and field measured water content was reached by the TDI inverse solution approach (RMSE: 0.050 cm3.cm-3). The inverse solution approach probed to be a simple and practical method to obtain an accurate estimate of both, SWRC and hydraulic conductivity curve.
O objetivo deste trabalho é comparar o uso da solução inversa na estimativa das propriedades hidráulicas do solo com a análise tradicional de dados por infiltrômetro de disco de tensão (IDT), dados de retenção em campo e funções de pedotransferência (FPTs) comumente usadas. Os dados de campo foram coletados em uma parcela experimental lo-calizada em Bahía Blanca, Argentina. A infiltração no campo sob condições saturadas foi medida pelo método do furo inverso e a infiltração sob condições insaturadas foi realizada com IDT. Os dados de retenção de campo (θ(h)) também foram coletados periodicamente. O software HYDRUS 2D/3D foi utilizado para otimizar os parâmetros hidráulicos do solo por solução inversa, de acordo com os dados do IDT. A condutividade hidráulica saturada medida pelo método do furo inverso (5.53 cm.h-1) e calculada pela abordagem analítica de Wooding (5.35 cm.h-1) e simulações numéricas inversas (5.36 cm.h-1) mostraram valores muito próximos. Segundo estimativas de macroporosidade, a água infiltrada é conduzida principalmente através de microporos e mesoporos do solo. Os macroporos canalizaram apenas 15.9% do fluxo total infiltrado. As curvas de retenção previstas pelos FPTs não representaram corretamente os dados de retenção em campo. O melhor ajuste entre o teor de água nas tensões específicas previstas pelas curvas de retenção e o teor de água medido no campo foi alcançado pela abordagem de solução inversade IDT (RMSE: 0.050 cm3.cm-3). A abordagem de solução inversa demonstrou ser um método simples e prático para obter uma estimativa precisa de curvas de re-tenção e de condutividade hidráulica.
Fil: Scherger, Leonardo Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca; Argentina. Universidad Nacional del Sur. Departamento de Geología; Argentina
Fil: Zanello, Victoria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca; Argentina. Comisión de Investigaciones Científicas de la Provincia de Buenos Aires. Centro de Geología Aplicada, Agua y Medio Ambiente; Argentina. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas; Argentina
Fil: Lexow, Claudio. Universidad Nacional del Sur. Departamento de Geología; Argentina
description The aim of this work is to compare the use of the inverse solution approach in the estimation of soil hydraulic properties with traditional tension disk infiltrometer (TDI) data analysis, field retention data and commonly used pedotransfer functions (PTFs). Field data were collected in an experimental plot located at Bahía Blanca, Argentina. Field infiltration under saturated conditions was measured by the inverse auger hole method and infiltration under unsaturated condi-tions were carried out with TDI. Field retention data (θ(h)) were also collected periodically. The HYDRUS 2D/3D software was used to optimize soil hydraulic parameters by inverse solution according to TDI data. The saturated hydraulic con-ductivity measured by inverse auger hole method (5.53 cm.h-1) and calculated by Wooding analytical approach (5.35 cm.h-1) and inverse numerical simulations (5.36 cm.h-1) showed very close values. According to macroporosity esti-mates infiltrated water is mainly conducted through soils micro and mesopores. Macropores only channeled 15.9% of total infiltrated flow. Soil water retention curves (SWRC) predicted by PTFs did not represented correctly field retention data. The best adjustment between water content at specific pressure heads predicted by SWRCs and field measured water content was reached by the TDI inverse solution approach (RMSE: 0.050 cm3.cm-3). The inverse solution approach probed to be a simple and practical method to obtain an accurate estimate of both, SWRC and hydraulic conductivity curve.
publishDate 2020
dc.date.none.fl_str_mv 2020-09-08
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/132704
Scherger, Leonardo Ezequiel; Zanello, Victoria; Lexow, Claudio; Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil; Associação Brasileira de Águas Subterrânea; Revista Aguas Subterraneas; 34; 3; 8-9-2020; 310-324
0101-7004
2179-9784
CONICET Digital
CONICET
url http://hdl.handle.net/11336/132704
identifier_str_mv Scherger, Leonardo Ezequiel; Zanello, Victoria; Lexow, Claudio; Comparison of the inverse modeling approach and traditional methods to estimate the unsaturated hydraulic properties in a sandy loam soil; Associação Brasileira de Águas Subterrânea; Revista Aguas Subterraneas; 34; 3; 8-9-2020; 310-324
0101-7004
2179-9784
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://aguassubterraneas.abas.org/asubterraneas/article/view/29929
info:eu-repo/semantics/altIdentifier/doi/10.14295/ras.v34i3.29929
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Associação Brasileira de Águas Subterrânea
publisher.none.fl_str_mv Associação Brasileira de Águas Subterrânea
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614394399424512
score 13.070432